Home > Adam Equipment > Pallet Beam > Adam Equipment AELP Pallet Beams AELPREVA6 User Manual

Adam Equipment AELP Pallet Beams AELPREVA6 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Adam Equipment AELP Pallet Beams AELPREVA6 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							©
     Adam Equipment Company 2005  
    Adam Equipment 
    AELP  
    PALLET BEAMS SCALES 
    (P.N. 4327, Rev. A6, June 2005) 
    Software revision: LAT 504   
    						
    							 
    © Adam Equipment Company 2005  
     
      
    						
    							 
    © Adam Equipment Company 2005  
      1
     
     
    CONTENTS 
        
    1.0
      INTRODUCTION ....................................... .................................................................... 2 
    2.0   TECHNICAL SPECIFICATIONS ........................... ........................................................ 3 
    3.0   UNPACKING THE SCALE ................................ ............................................................ 4 
    4.0   SETTING UP THE SCALE ............................... ............................................................. 4 
    5.0   KEYPAD AND DISPLAY ................................. .............................................................. 5 
    5.1   KEY
     DESCRIPTION ........................................ .......................................................... 5 
    5.2   DISPLAY
     SYMBOLS............................................ ...................................................... 6 
    6.0   FUNCTIONS.......................................... ........................................................................ 6 
    6.1  
    BL = AUTOMATIC BACKLIGHT CONTROL ............................................ .................... 7 
    6.2  
    AVE = DISPLAY AVERAGING RATE ............................................... ........................... 8 
    6.3  
    FIL = ADC FILTER RATE ............................................... ............................................. 8 
    6.4  
    BOD = BAUD RATE SELECTION .......................................... ....................................... 8 
    6.5  
    CONT  = CONTINUOUS PRINTING ........................................... .................................... 9 
    6.6  
    PIECE = PARTS COUNTING........................................... ............................................. 9 
    6.7  
    STEPS = CHECK-WEIGHING FUNCTION (LOW-OK-HIGH) ..................................... 1 1 
    6.8  
    CALIBR  = CALIBRATION ROUTINE ............................................ .............................. 12 
    6.9  
    REPL = RESULTS PRINTED AUTOMATICALLY OR MANUALLY ............................. 12  
    6.10  
    STAB = PRINT WHEN STABLE OR INSTANTANEOUS ...................................... ....... 13 
    6.11  
    AUT = AUTOZERO FUNCTION ........................................... ...................................... 13 
    6.12  
    T1 = AUTOMATIC POWER SWITCH OFF ................................................ ................ 14 
    6.13  
    TOP = HOLD MAXIMUM VALUE .............................................. .................................. 14 
    6.14  
    NE = WEIGH IN NEWTONS ............................................ .......................................... 14 
    6.15  
    SUPP = POW ER SUPPLY VOLTAGE TO PCB ................................................ .................... 15 
    7.0   COMMUNICATION WITH A COMPUTER/PRINTER.............. .................................... 15 
    7.1   PARAMETER.......................................... ................................................................. 15 
    7.2   CONNECTION ......................................... ................................................................ 15 
    7.3   OUTPUT
     FORMAT ............................................. ..................................................... 16 
    7.4   INPUT
     COMMANDS FORMAT ............................................. ................................... 16 
      
    						
    							 
    © Adam Equipment Company 2005  
      2
     
     
    1.0  INTRODUCTION 
                 
     
    AELP Pallet Beam Scales come with the following sta ndard features: 
     
      Lightweight for ease of handling 
       Supplied complete with the AE 106 Indicator in pla stic housing  
       Precision load cells for accurate weighing results  every time 
       5 weighing units for flexibility 
       Handles for portability 
       Low profile beams to allow easy weighing of pallet s 
       2 beams per set  
       Mains adapter supplied as standard 
          
    						
    							 
    © Adam Equipment Company 2005  
      3
     
     
    2.0  TECHNICAL SPECIFICATIONS 
       
    Mod els 
    Ma xim um C ap acity
    Readabil ity
    Repea tabi lity Linearity (±)
    Internal countin g resol utio n
    Tare r ange 
    Stabili sation tim e 
    Units of measu re 
    Interface 
    Operating tem perature
    Pow er su pp ly
    Ca libration Disp lay
    Pan size
    Functions
    Other featur es AELP 5 00
    AELP 2 000
    5 00  kg 2000 kg
    2 00  g 5 00  g
    2 00  g 500 g 
    2 00  g 1 00 0 g
    Up  to  60,000 d ivisi ons Full
    Typically 3 seconds
    Kg, g, t or l b
    RS-232 bi -d ire cti onal  In ter fa ce 
    0 to 40 ° C
                        10.5 VAC external a da pter 
    6  x AA size Alkalin e Dr y-cell b atter ies are suggest ed
    Push button  calibration
    16 mm  LCD d isp lays
    1250 x 80  x 60  mm 
        Averaging l evel, baud rate, pri nt wh en   
    sca le become s stable or manual ly, pr int when  
         stable o r at any tim e, auto- zero di sab le,  
    auto matic pow er  o ff, enable maximum value  
            hol d, ena ble we igh ing in Ne wtons  Par ts Counting and Check-w eig hing
    Ne t w eight
    Resol ution 200 g
    5 00  g
    28.3 kg 
    						
    							 
    © Adam Equipment Company 2005  
      4
     
     
    3.0  UNPACKING THE SCALE 
         
    
      Remove the 2 sets of pallet beams using the handle s provided. 
     
      Take care while removing the beams to avoid bangin g or injury. 
     
      Remove the Indicator and the power supply adapter  packed seperately. 
     
      Place it on a levelled and firm floor. 
     
      Position the beams side by side. 
      
             
    4.0  SETTING UP THE SCALE 
       
      Plug  in  the  Indicator  into  the  socket  provided  at  the  back  of  the 
    pallet beam (the one having two sockets). 
     
      Ensure  both  the  beams  are  connected  via  the  beam-t o-beam 
    cable. 
     
      Attach the Power Supply adapter to the Indicator a nd switch the 
    main supply to ON. 
     
      The  Indicator  can  also  be  operated  by  using  6  x  AA   size 
    batteries. (Alkaline batteries suggested). 
     
      Read this User Manual before starting the weighing  operation. 
     
      Place the pallets on the beams for weighing.      
        
    						
    							 
    © Adam Equipment Company 2005  
      5
     
     
    5.0  KEYPAD AND DISPLAY 
      
    5.1  KEY DESCRIPTION 
     
     
    [On/Off]  Turns the scale on or off
     
    [Print] Initiates the RS-232 transmission 
     
    [Func] Sets functions
     
    [Zero]  Sets the display to zero with no weight on the plat
    form. 
    [Tare]   Sets the display to zero by storing the current wei
    ght in the tare memory 
       
      Turn  the  scale  on  using  the  [On/Off]  key.  After  the  display  is 
    zero,  place  an  item  to  be  weighed  on  the  platform.  The  display 
    will show the weight. The unit will be grams or kil ograms as set by 
    the supplier. 
     
      To zero the display with no weight on the platform , press [Zero].   
     
      If  a  container  is  placed  on  the  platform  press  [Tare]  to  zero  the 
    display.  As  material  is  added  to  the  container  only   the  weight  of 
    the  material  will  be  displayed.  If  necessary  press  [Tare]  again  to 
    add  more  material  if  desired.  Trying  to  tare  a  nega tive  value  will 
    give the error “-  VAL”. 
     
      If the weight on the platform exceeds the permissi ble range of the 
    [Zero]   key  (±4%  of  capacity)  the  message  “ VAL  4”  will  be  shown 
    briefly.  Either  remove  some  weight  or  press  [Tare]  to  zero  the 
    display. 
       
    						
    							 
    © Adam Equipment Company 2005  
      6
     
    5.2  DISPLAY SYMBOLS 
     
    Symbol  Description 
    ZERO   
    Scale in auto zero range (indication = accurate zer
    o) 
    STAB   Result is stable  
    PCS   Scale in parts counting mode 
    kg 
    or g  or t  Scale in weighing mode 
    BAT-LO  Batteries are weak, after 5 minutes the scale will 
    turn off  
    TARE Scale has been tared 
     When weight is above the High setpoint 
     When weight is between the setpoints 
      When weight is below the Low
     setpoint 
    - Lo -    During parts counting sample size is too small 
          
    6.0  FUNCTIONS 
        
    
      To change functions press the  [Func] key.  
     
      The  functions  that  are  available  can  be  cycled  thr ough  by 
    pressing  [Func] key.  
     
      Not  all  functions  may  be  enabled.  Some  functions  m ay  be  set 
    during  the initial configuration and the user is no t given access to 
    them.  In  this  case  those  will  not  be  seen  when  the  [Func]  key  is 
    pressed.  
     
       To  use  any  of  the  functions  see  the  corresponding  section  of  the 
    manual. 
     
       If  you  continue  to  press  the  [Func]  key  you  will  eventually  be 
    returned to weighing. 
     
    F u n c t i o n s   A v a i l a b l e  
      Function Description 
    1.  bL Enables / disables the backlight (if used) 
    2.  AVE Changes averaging of weighing result   
    3.  bod Changes baud rate for RS-232 transmission speed 
    4.  FIL Changes ADC filtering 
    5.  cont Enables or disables continuous printing 
    6.  PIECE* Enters parts counting  
    						
    							 
    © Adam Equipment Company 2005  
      7
     
    7.  StEPS* Enters check-weighing   
    8.  CALIbr Calibration routine 
    9.  rEPL Sets RS-232 to transmit automatically or manually  
    10. StAB Sets the RS-232 to print only when stable or at any
     time 
    11. Aut Enables/disables the autozero function  
    12. t1 Enables/disables the automatic turn off  
    13. toP Enables/disables the maximum hold feature 
    14. nE Changes to measuring in Newtons  
    15. SuPP Displays the power supply voltage 
        
      Most  functions  only  require  a  simple  enable  or  dis able  (0  or  1)  or 
    a  number  that  is  incremented.  Select  the  function  u sing [Func] , 
    then  press  [Print]  to  view  the  current  setting.  Pressing  [Print] 
    again  will  change  the  setting  to  the  next  value.  Pr essing [Func] 
    again will return to normal weighing. 
     
      On  other  functions  (marked  *)  select  the  function  by  pressing 
    [Func] .  Press  [Print]  to  enter  the  function  menu.  The  program 
    will  then  prompt  you  to  enter  values  depending  upon   the  function 
    selected.  It  is  necessary  to  use  [Tare]  to  select  a  digit  to  change 
    and  press  [Print]  to  increment  the  flashing  digit.  When  all  digits 
    have been entered press  [Func] to go to the next step. 
      
    6.1 bL = AUTOMATIC BACKLIGHT CONTROL 
     
      If the scale includes a backlight, it can be eithe r enabled or 
    disabled. 
       To set the parameter press the  [Func] key to show “ bL” 
       Press  [Print] to see the parameter.  
       Press  [Print] to select either “ bL= 0” or “bL= 1”. 
      “ bL= 0 “   Backlight is enabled. 
      “ bL= 1”  Backlight is disabled. 
       Press the  [Func] key to return to weighing.  
    						
    							 
    © Adam Equipment Company 2005  
      8
     
    6.2 
    AVE = DISPLAY AVERAGING RATE 
     
      It selects the required averaging for the display  update. 
       Press the  [Func] key until  AVE is displayed.  
       Press  [Print] to select the desired value. 
       Press the  [Func] key to return to weighing. 
        AVE 1  =  Fastest display rate for uses such as filling. 
        AVE 5  =  Slowest display rate for uses such as animal wei ghing  
            or poor environment. 
      Press the  [Func] key to return to weighing. 
     
     
    6.3  FIL = ADC FILTER RATE 
     
      It selects the required filter rate. 
       Press the  [Func] key until  FIL is displayed.  
       Press  [Print] to select the desired value. 
       Press the  [Func] key to return to weighing. 
        FIL 1  =  Fastest rate for speed. 
        FIL 4  =  Slowest rate for poor environment. 
     
      Press the  [Func] key to return to weighing. 
     
    6.4 bod = BAUD RATE SELECTION 
     
      It selects the required baud rate for the RS-232 c ommunications. 
       Press the  [Func] key until ” bod” is displayed.  
       Press  [Print] to select the desired value. 
        bod 1    =     300 Baud  
        bod 2    =     600 Baud 
        bod 3    =   1200 Baud 
        bod 4    =   2400 Baud 
        bod 5    =   4800 Baud (default) 
        bod 6    =   9600 Baud  
      Press the  [Func] key to return to weighing. 
      
    						
    All Adam Equipment manuals Comments (0)