Page 21
19 | P a g e © Adam Equipment Company 2010 6.8.1 ANIMAL WEIGHING PROCEDURE With the platform empty the display will show zero w eight. Place containers or blankets onto the platform and press the [Z/T] key to zero the display. The scale may go into the animal (dynamic) weighing pro cedure when the items are placed on the scale but will return to showing zero when the [Z/T] key is pressed. Place the animal or sample to be weighed on the...
Page 22
20 | P a g e © Adam Equipment Company 2010 7.0 USER PARAMETERS Pressing the [Func/C] key during normal operation allows the user to access the parameters for customizing the scale. The parameter s are split into 4 groups- 1. Check weighing parameters, 2. Percent and Animal Weighing Functions 3. RS-232 parameters and 4. Scale parameters When [Func/C] is pressed, display will first show “FunC 1” for Check weighing parameters. Press either...
Page 23
21 | P a g e © Adam Equipment Company 2010 Parameter Description Options Default setting F1 Lo Set Low limit. Use the [Unit/ ] key and [Pcs/ ] key to set the values of the lower limit. When set press the [Z/T] key to store the value and go to F2 Hi 000000 F2 Hi Set High limit. Use the [Unit/ ] key and [Pcs/ ] key to set the values of the high limit. When set press the [Z/T] key to store the...
Page 24
22 | P a g e © Adam Equipment Company 2010 Press [Print/M+/Esc] to return to the group “FUnC 2”. If you press [Print/M+/Esc] again, the scale will exit the User Parameter secti on and return to weighing. Parameter Description Options Default setting P1 PCt This parameter allows the user to enter the Percent weighing Function. See Section 6.7. None Enabled always P2 AnL Enter the Animal Weighing mode of operation, See...
Page 25
23 | P a g e © Adam Equipment Company 2010 C3 PrM Printing Mode- Manual, Continuous or Automatic mAn , Cont (not on EC approved scales) AUto mAn C4 Aon Enable or disable the Accumulation AC on AC oFF AC on C5 Ln Select Language EnGLi (English) FrEnCH (French) GErmAn (German) SPAn (Spanish) EnGLi C6 UId Set User ID To be entered manually 000000 C7 Sid Set Scale ID To be entered manually 000000 Scale will perform the...
Page 26
24 | P a g e © Adam Equipment Company 2010 This group of parameters is used to control the operation of the scale. Parameter Description Options Default setting S1 Un Enable or disable weighing units, will not allow to disable all units, at least one has to be enabled. Parts counting can be enabled/disabled Kg Grams lb oz lb:oz N (Newtons) PCS Kg S2 bL Backlight set to always on, always off or automatic on whenever a weight is...
Page 27
25 | P a g e © Adam Equipment Company 2010 8.0 BATTERY OPERATION The scales can be operated from the battery if desi red. The battery life can be up to 70 hours depending on the load cells u sed and how the backlight is used. When the battery needs charging a symbol on the dis play will show less bars in the battery symbol. The battery should be charged when only the battery outline is on. Once the bars have been turned off the...
Page 28
26 | P a g e © Adam Equipment Company 2010 31 2 4 9.0 RS-232 INTERFACE The AE 402 indicator is supplied with bi-directiona l RS-232 interface as standard. The scale when connected to a printer or computer o utputs the weight with the selected weighing unit through the RS-232 interface . Specifications: RS-232 serial interface is a plug as figure 2 shows : 1: Pin GND, Signal Ground 2: Pin RXD, Received Data...
Page 29
27 | P a g e © Adam Equipment Company 2010 Data Format-Normal Output: Only weight value along with the weighing unit is printed. If Percent weighing is used then % is shown in place of weighing units. Data Format-Parts Counting Output: Weight, Unit weight and number of parts are printed. Date 12/09/2006 Time 14:56:27 Scale ID 123456 User ID 234567 Net Wt. 1.234 Kg Net Wt. (or Gross Wt.) Unit...
Page 30
28 | P a g e © Adam Equipment Company 2010 Data Format- Memory Recall Output: Data Format- Continuous Output- Normal weighing: Data Format- Continuous Output- Parts Counting: NOTE: 1. The accumulated total will not be sent to the RS-23 2 when the continuous print is turned on. 2. The continuous print will only be for the current w eight and the display data. 3. In other languages the format is the same but the t ext will be in the language...