19 | P a g e © Adam Equipment Company 2010 6.8.1 ANIMAL WEIGHING PROCEDURE With the platform empty the display will show zero w eight. Place containers or blankets onto the platform and press the [Z/T] key to zero the display. The scale may go into the animal (dynamic) weighing pro cedure when the items are placed on the scale but will return to showing zero when the [Z/T] key is pressed. Place the animal or sample to be weighed on the pla tform. The display will show the Animal/Dynamic weighing s ymbol until a stable weight is determined. The time it takes for the st able value will depend upon the setting of the filter parameter in the first st ep. When a stable reading is found, the display will sho w this value, and the display will be locked until the [Z/T] key is pressed. The display will show the “Hold” symbol while the display is locked. To weigh a second subject press the [Z/T] key if necessary to zero the display, and place the next animal on the scale. The scale w ill detect the new weight and hold it as before. The scale will remain in the animal weighing mode u ntil the [Unit/ ] key is pressed. Then it will return to normal weighing.
20 | P a g e © Adam Equipment Company 2010 7.0 USER PARAMETERS Pressing the [Func/C] key during normal operation allows the user to access the parameters for customizing the scale. The parameter s are split into 4 groups- 1. Check weighing parameters, 2. Percent and Animal Weighing Functions 3. RS-232 parameters and 4. Scale parameters When [Func/C] is pressed, display will first show “FunC 1” for Check weighing parameters. Press either the [Func/C] key or the [Pcs/ ] to advance through the groups “FunC 1” , “FunC 2” , “FunC 3” and “FunC 4” . Press [Z/T] to enter the desired group of parameters. When in one of the sections press [Print/M+/Esc] to return to the group “FunC 1” . If you press [Print/M+/Esc] again, the scale will exit the User Parameter section and return to normal weighing. 7.1 CHECK WEIGHING PARAMETERS Press [Z/T] to enter the group. Use the [Unit/ ] key and [Pcs/ ] key to set the values or just the [Pcs/ ] key to select the options. Press [Z/T] to confirm the change and then advance to the next parameter by pressing the [Pcs/ ] key. This group of parameters- - Set low and high limits for check-weighing - Enables or disables the check weighing alarm - Enables or disables the negative check weighing
21 | P a g e © Adam Equipment Company 2010 Parameter Description Options Default setting F1 Lo Set Low limit. Use the [Unit/ ] key and [Pcs/ ] key to set the values of the lower limit. When set press the [Z/T] key to store the value and go to F2 Hi 000000 F2 Hi Set High limit. Use the [Unit/ ] key and [Pcs/ ] key to set the values of the high limit. When set press the [Z/T] key to store the value and go to F3 bEP 0000000 F3 bEP This parameter sets the Beeper to off or on. If set to on, the beeper can further be set to sound when the weighing result is within or outside the check-weighing limits. bP oFF - Off bP inL - Within limits bP otL - Outside limits (>20d) bP inL F4 nCK This parameter enables negative check weighing function with ability to do negative tare. on oFF on 7.2 PERCENT WEIGHING AND ANIMAL WEIGHING See section 6.7 and 6.8 for details of these spec ial weighing modes. Press [Z/T] to enter a parameter. Use the [Unit/ ] key and [Pcs/ ] key to set the values or just the [Pcs/ ] key to select the options. Press [Z/T] to confirm the change and then advance to the next parameter by pressing the [Pcs/ ] key.
22 | P a g e © Adam Equipment Company 2010 Press [Print/M+/Esc] to return to the group “FUnC 2”. If you press [Print/M+/Esc] again, the scale will exit the User Parameter secti on and return to weighing. Parameter Description Options Default setting P1 PCt This parameter allows the user to enter the Percent weighing Function. See Section 6.7. None Enabled always P2 AnL Enter the Animal Weighing mode of operation, See section 6.8 Set the filter value. Enabled Always 7.3 RS-232 PARAMETERS Press [Z/T] to enter a parameter. Use the [Unit/ ] key and [Pcs/ ] key to set the values or just the [Pcs/ ] key to select the options. Press [Z/T] to confirm the change and then advance to the next parameter by pressing the [Pcs/ ] key. Press [Print/M+/Esc] to return to the group “FUnC 3”. If you press [Print/M+/Esc] again, the scale will exit the User Parameter secti on and return to weighing. This group of parameters can be set by the user for setting the RS-232 active or not, baud rate, printing mode, accumulation mode, RS-232 language, and user or scale ID numbers. Parameter Description Options Default Values or setting C1 on Enable or disable the RS-232 interface Prt on Prt oFF Prt on C2 bd Baud Rate 600 1200 2400 4800 9600 19200 9600
23 | P a g e © Adam Equipment Company 2010 C3 PrM Printing Mode- Manual, Continuous or Automatic mAn , Cont (not on EC approved scales) AUto mAn C4 Aon Enable or disable the Accumulation AC on AC oFF AC on C5 Ln Select Language EnGLi (English) FrEnCH (French) GErmAn (German) SPAn (Spanish) EnGLi C6 UId Set User ID To be entered manually 000000 C7 Sid Set Scale ID To be entered manually 000000 Scale will perform the following, depending on the Accumulation and Print Settings: ACCUMULATION SETTINGS PRINT SETTINGS AC on AC Off AUto Accumulate and print automatically Print automatically, Do not accumulate mAn Accumulate and Print only when [Print/M+/Esc] key pressed. If [Print/M+/Esc] is pressed a second time only print the weight. Print when [Print/M+/Esc] key is pressed, Do not accumulate. Cont Not available on approved scales Print continuously. Accumulate when [Print/M+/Esc] key is pressed Print continuously. Do not accumulate. 7.4 SCALE PARAMETERS Press [Z/T] to view the list of parameters. Press [Z/T] to enter a parameter. Use the [Unit/ ] key and [Pcs/ ] key to set the values or just the [Pcs/ ] key to select the options. Press [Z/T] to confirm the change and then advance to the next parameter by pressing the [Pcs/ ] key. Press [Print/M+/Esc] to return to the group “FUnC 4”. If you press [Print/M+/Esc] again, the scale will exit the User Parameter secti on and return to normal weighing.
24 | P a g e © Adam Equipment Company 2010 This group of parameters is used to control the operation of the scale. Parameter Description Options Default setting S1 Un Enable or disable weighing units, will not allow to disable all units, at least one has to be enabled. Parts counting can be enabled/disabled Kg Grams lb oz lb:oz N (Newtons) PCS Kg S2 bL Backlight set to always on, always off or automatic on whenever a weight is placed or a key is pressed EL oFF EL on EL AU EL AU S3 AoF Auto Off- Disable or set time increment to turn off scale SLP 0 SLP 1 SLP 5 SLP 10 SLP 0 S4 dt Set Time and Date format and settings. Format for date can be changed when the display shows mmddyy, ddmmyy or yymmdd by pressing the [Pcs/ ] key, then enter the date. Enter the time manually. Enter the date format and then the numeric value manually. 00:00:00 mm:dd:yy S5 diS Display all weights or only when stable ALL StAb ALL S6 Fi Filter setting to slow, normal or fast SLow nor FASt nor S7 SPS Password Enter new pass word twice,, controls access to Func 1 to Func 4 Not active S8 CAL Calibration Calibrate the scale. See Section 11.0 -
25 | P a g e © Adam Equipment Company 2010 8.0 BATTERY OPERATION The scales can be operated from the battery if desi red. The battery life can be up to 70 hours depending on the load cells u sed and how the backlight is used. When the battery needs charging a symbol on the dis play will show less bars in the battery symbol. The battery should be charged when only the battery outline is on. Once the bars have been turned off the scale will still operate for a short time after which it will automatically switch off to protect the battery. To charge the battery, simply plug the adaptor into the mains power. The scale does not need to be turned on. The battery should be charged for 12 hours for full capacity. Near the display is an LED to indicate the status o f battery charging. When the scale is plugged into the mains power the internal battery will be charged. If the LED is green the battery has a full charge. If it is Red the battery is nearly discharged and yellow indicat es the battery is being charged.
26 | P a g e © Adam Equipment Company 2010 31 2 4 9.0 RS-232 INTERFACE The AE 402 indicator is supplied with bi-directiona l RS-232 interface as standard. The scale when connected to a printer or computer o utputs the weight with the selected weighing unit through the RS-232 interface . Specifications: RS-232 serial interface is a plug as figure 2 shows : 1: Pin GND, Signal Ground 2: Pin RXD, Received Data 3: Pin TXD, Transmitted Data As viewed from the back of the indicator The scale can be set to print text in English, Fren ch, German or Spanish. See the RS- 232 parameters section for details. RS-232 output of weighing data ASCII code 9600 Baud (user selectable) 8 data bits No Parity
27 | P a g e © Adam Equipment Company 2010 Data Format-Normal Output: Only weight value along with the weighing unit is printed. If Percent weighing is used then % is shown in place of weighing units. Data Format-Parts Counting Output: Weight, Unit weight and number of parts are printed. Date 12/09/2006 Time 14:56:27 Scale ID 123456 User ID 234567 Net Wt. 1.234 Kg Net Wt. (or Gross Wt.) Unit Wt. 123 g g for metric and lb for pounds PCS 10 pcs Date 12/09/2006 Time 14:56:27 Scale ID 123456 If ID is zero, it is left blank User ID 234567 Net Wt 1.234 Kg Net Wt. (or Gross Wt.)
28 | P a g e © Adam Equipment Company 2010 Data Format- Memory Recall Output: Data Format- Continuous Output- Normal weighing: Data Format- Continuous Output- Parts Counting: NOTE: 1. The accumulated total will not be sent to the RS-23 2 when the continuous print is turned on. 2. The continuous print will only be for the current w eight and the display data. 3. In other languages the format is the same but the t ext will be in the language selected. Date 12/09/2006 Time 14:56:27 Scale ID 123456 User ID 234567 ------------------ TOTAL No. 5 Wt. 1.234 Kg PCS 10 pcs ------------------ ST,GROSS 1.234 Kg ST or US for STable or UnStable, US,NET 0.000 Kg NET or GROSS for Net Weight or Gross wt. and the weighing unit, kg, lb etc. ST Net 1.234 Kg Net Weight (or Gross wt.) U.W. 123 g Kg and g for metric and Lb for pounds PCS 10 pcs