    							Auxiliary Machine 
    Interface (AMI) 
    						
    							23211 Auxiliary Machine Interface (AMI)
    11.1 Auxiliary Machine Interface (AMI)
    11.1  Auxiliary Machine Interface 
    (AMI)
    Machine Functions Menu
    The MILLPWRG2 software can be configured to access the Machine 
    Functions menu. This menu includes a set of soft keys that provide 
    manual access, and control of some features specific to AMI
    G2. 
    The machine tool builder enables the soft keys when the AMIG2 is 
    configured.
    Once enabled, the menu can be accessed while at the 
    DRO screen, or while a running program is paused, by 
    pressing the Machine Functions soft key.
    To exit the Machine Functions soft keys and return to the main 
    operations soft keys, press the CANCEL key. 
    A program run cannot be started, and a running program cannot be 
    continued, until after exiting the Machine Functions Menu.
    The Machine Functions Menu has the following soft keys:
    Soft keyFunction
    S_FWD: Turns the spindle motor ON in the Forward 
    direction.
    S_REV: Turns the spindle motor ON in the Reverse 
    direction
    S_OFF: Turns the spindle motor OFF
    Cool: Toggles the Coolant Flood circuit ON or OFF
    Mist: Toggles the Coolant Mist circuit ON or OFF
    Custom Cycles: Demo only
    Auxiliary Functions: Switches the menu to the 
    Auxiliary Functions menu that provides the following 
    soft keys:
    Aux Output 1, 2, 3, and 4: Toggles the Auxiliary 
    Outputs 1 through 4 ON or OFF
    Back: Switches the menu back to the previous set of 
    soft keys. 
    						
    							Software Update 
    						
    							23412 Software Update
    12.1 Updating System Software
    12.1 Updating System Software
    Software update
    If desired as a precautionary method, a backup of the controls internal 
    drive can be made prior to updating the system software, by using the 
    included USB Recovery Drive (1127022-xx). Please refer to the manual 
    included with the drive for the backup procedure.
    Use a blank USB memory stick (1 GB or larger) to update the software. 
    Do not use any memory stick with a smaller storage capacity.
    A ZIP file must be obtained which includes the software installation 
    files. The ZIP can be extracted to the root of the empty USB drive. 
    When the control software is started, if a USB drive is present which 
    contains a software update, the control will automatically start a 
    software update. The required folder structure for the software update 
    on the USB drive is as follows: 
    :\install\setup.zip.
    Procedure for updating the software
    Shut down the control software using the normal method of 
    pressing the Shutdown soft key.
    Press the Restart soft key to initiate the reboot sequence.
    Insert the USB memory device containing the folder named install 
    into an available USB port on the console.
    After starting, the MILLPWRG2 Software Update screen will appear 
    with a confirmation box. If necessary, use the UP/DOWN ARROW keys to 
    select the language (e.g. English) and press ENTER.
    A confirmation box will appear.  If necessary, use the LEFT or RIGHT 
    ARROW keys to select Yes, then press ENTER.
    The software update will now be done automatically, taking about 
    10 minutes.
    When the update is complete, it will prompt you to remove the USB 
    drive and restart. At this time, remove the USB drive and press 
    ENTER to restart.
    After the system has restarted, it will start up normally to the control 
    software.
    If any issues are encountered, please either refer to the technical 
    manual or contact your service representative for assistance.
    If the USB memory stick used for installation is not 
    removed, then the prompt to install the software will 
    continue to appear on subsequent power cycles.   
    						
    							Off-Line Software 
    						
    							23613 Off-Line Software
    13.1 MILLPWR
    G2
     Off-Line Software
    13.1  MILLPWRG2 Off-Line Software
    Off-line simulator
    The off-line software provides a convenient way to write part 
    programs and simulate machine behavior using a standard Windows®  
    computer.  Features and functionality are virtually identical to that of 
    the MILLPWR
    G2 control itself.
    System requirements
    Platform: IBM compatible PC.
    Operating System: All 32-bit and 64-bit editions of ** Windows 
    Vista/7/8/8.1 are supported.
    Available Drive Space: 2GB or higher.
    Memory: 1GB or higher.
    Display Resolution: 1024x768 (XGA) or higher required. 1440 x 900 
    (WXGA+) recommended.
    Ports: One available USB port for protection device.
    Peripherals: Keyboard and pointing device.
    **Microsoft
    ® ,Windows® , and Vista® are registered trademarks of 
    Microsoft Corporation in the United States and/or other countries. 
    						
    							ACU-RITE MILLPWRG2 237
    13.1 MILLPWR
    G2
     Off-Line Software
    Installation
    The software is installed in the usual manner by launching the setup 
    program, selecting an installation destination, and choosing the 
    desired features to be installed.  Using the default setting for a 
    Complete feature installation is highly recommended to ensure 
    proper functionality.  On some systems, you may be required to 
    restart the computer after installation before the application will 
    display properly.
    Operation
    Before using the off-line software, a USB Protection Module (ID. 
    683048-01, 683049-01, or 683050-01) must be inserted into an 
    available USB port on the computer. If no USB protection dongle is 
    installed, the software will not allow operation.  
    The off-line software can be started by using either the MILLPWR
    G2 
    Off-Line shortcut created on your desktop during installation or from 
    the Start menu.  Once the software is running, it is operated in the 
    same manner as the machine itself.  Similarly, it should be shut down 
    using the same sequence of selecting Shutdown and confirming 
    Shutdown at the prompt.  If for some reason the software becomes 
    unresponsive, a force quit can be done using the ShutDown 
    MILLPWR
    G2 shortcut created on your desktop during installation or 
    from the Start menu.  Normal shutdown procedure should be used 
    unless the force quit method is absolutely required.
    Programs created in the off-line software can be copied to the CNC, 
    and (with the correct setup) run on your machine. 
    						
    							23813 Off-Line Software
    13.1 MILLPWR
    G2
     Off-Line Software
    On screen keypad
    The MILLPWRG2 Off-Line software includes an on-screen keypad 
    application.  This can be used to simulate the hard keys that are 
    normally available on the machine console.  Pressing the buttons on 
    the keypad application will activate the same operation that would 
    occur when pressing the corresponding buttons on the machine 
    console. 
    The Feed slider only allows a range of 1% - 100%. The SPEED slider 
    only functions with certain software versions and configurations.
    The keypad application will automatically start and shutdown when 
    the MILLPWR
    G2 software is started and shutdown.  If necessary, the 
    keypad application can be manually shutdown by clicking the red X 
    button in the top right corner of the keypad window.  Likewise, if 
    necessary, the keypad application can be manually started using the 
    Launch Keypad shortcut located in the Windows® Start Menu, under 
    All Programs - ACU-RITE - MillPWR Off-Line.
    Keyboard shortcuts
    The keys on the MILLPWRG2 keypad can be simulated using the key 
    combinations described below. These can be used when the 
    on-screen keypad is closed or when the PC keyboard is connected to 
    a MILLPWR
    G2 console
    KeysShortcut
    Alt + T   (Tool)
    Alt + R   (Rectangle)
    Alt + C   (Circle)
    Alt + H   (Holes)
    Alt + P   (Position)
    Alt + L   (Line)
    Alt + A   (Arc)
    Alt + B   (Blend/Chamfer) 
    						
    							ACU-RITE MILLPWRG2 239
    13.1 MILLPWR
    G2
     Off-Line Software
    KeysShortcut
    Alt + I   (Absolute/Incremental)
    Alt + D   (DRO/Program mode)
    Alt + V   (Display View)
    Alt + U   (User ID)
    Alt + N   (On screen User Manual)
    Alt + F   (Inch/MM)
    Alt + Enter   (Configuration menu)
    Alt + K   (Calculator)
    F12  (Plus/Minus Toggle)
    F12  (Plus/Minus Toggle)
    Esc   (Cancel)
    Del   (Clear)
    Alt + Enter   (Use)
    Enter   (Enter)
    Alt + J   (Press once: Pause / Press Twice: Stop)
    Alt + S   (Go) 
    						
    							24013 Off-Line Software
    13.1 MILLPWR
    G2
     Off-Line Software
    Numeric, and ARROW keys:
    The ARROW keys on a standard PC keyboard will simulate the console 
    ARROW keys, and the number keys will simulate the console number 
    keys (using number lock).  When number lock is turned off, the ARROW 
    keys on the number keys (2, 4, 8, 6) will simulate the console ARROW 
    keys.
    Updating
    It is not necessary to un-install the software before installing updates.  
    Running the new setup program will update the existing installation to 
    the newer version.  Although your created part programs will remain 
    intact, it is always recommended to make a backup of your programs 
    and/or configurations before updating the software installation.
    Soft keysShortcut
    1F1
    2F2
    3F3
    4F4
    5F5
    6F6
    7F7
    8F8 
    						