21 Specifications Receiver Locating ModesDual Peak w/Direction, Special (Single) Peak, Induction Peak, Depth & Current Gain Adjustment Automatic with Manual override Frequencies Active Passive Power Passive LF Passive CATV Cathodic Protection Auxiliary/Sonde (Receive only) 8 kHz, 82 kHz 50 Hz or 60 Hz VLF 15 k – 30 kHz 31.5 kHz * 100 Hz or 120 Hz 512 Hz, 640 Hz, 33 kHz Display Resolution 0.1 dB Depth Display Range 0–30 ft (9 m) Depth Units inch and cm Depth Accuracy ** ± 2% ± 3 in (5 cm) 0–60 in (1.5 m) ± 6% ± 3 in (5 cm) 61–120 in (1.5 m–3 m) ± 10% ± 3 in (5 cm) 121–180 in (3–4.5 m) Cable Current Display 0.01 mA resolution Units: mA Battery type 8 AA size, Alkaline (LR6) Typical Battery Life 30 hrs Display Large Graphic high contrast LCD w/ backlight Speaker 0.25 W Headphone Jack Standard Mini Jack Serial Port Standard RS232 serial w/DB9 connector * American NTSC, television set on ** Locators are tested in model field conditions with no adjacent signals. Actual operating conditions may result in decreased depth accuracy due to outside signal disruptions. Transmitter: 3-Watt Output Frequencies Trace Mode Induction mode 8 kHz, 82 kHz 82 kHz Output voltage (max) Trace 60 Vrms Output Power Normal setting: 0.5 W High setting: 3 W @ 8 kHz, 1 W @ 82 kHz Output Protection 240 Vrms Battery type 6 C size, Alkaline (LR14) Typical Battery Life Normal output level: 45 hrs High output level: 7 hrs
22 Transmitter: 12-Watt Output Frequencies Trace Mode Induction mode8 kHz, 82 kHz 8 kHz, 82 kHz Output voltage (max) Trace 60 Vrms Output Power, U-Model (Direct Connection Method) Output Power up to 12 Watts for the 12 Watt Transmitter is achieved using the supplied exter - nal power source. 12 Watt Output Power varies by frequency, or is limited to 1 Watt at 82 kHz on the U-Model using direct connection method. Normal setting: 0.5 W High setting: 3 W @ 8 kHz, 1 W @ 82 kHz Max setting: 12W @ 8 kHz, 1 W @ 82 kHz Output Power, E-Model (Direct Connection Method) Normal setting: 0.5 W High setting: 3 W @ 8 kHz and 82 kHz Max setting: 12 W @ 8 kHz and 82 kHz Output Protection 240 Vrms Battery type For Normal and High Output Power: 6 C size, Alkaline (LR14) For Max Output Power: Rechargeable Battery, 12V-6AH, Sealed Maintenance-Free Lead (Pb)-Acid Battery (See safety information below.) Typical Battery Life Normal output level: 45 hrs High output level: 7 hrs Rechargeable battery will extend operation time by 40%. Environmental Operating Temperature–4° F to 122° F (–20° to 50° C) Storage Temperature –4° F to 158° F (–20° to 70° C) Standard IP54 Regulatory 3 Watt Transmitter is FCC and CE compliant U-Model Transmitters meet FCC Part 15 12 Watt U-Model Transmitter is FCC compliant 12 Watt E-Model Transmitter is CE compliant Physical Specification Size (H x W x D) in (cm)Weight Transmitter 6.75 x 11.25 x 7.75 (17.2 x 28.6 x 19.7) w/ alkaline batteries only : 5.2 lb (2.4 kg) w/ rechargeable battery and alkaline batteries (12- watt transmitter only) : 9.2 lb (4.2 kg) Receiver 10.25 x 10.5 x 30 (26.7 x 26.1 x 76.2) 4.05 lb (1.9 kg) Shipping N/A 17 lb (7.7 kg) - standard units 21 lb (9.5 kg) - 12-watt transmitter units with rechargeable battery
23 Rechargeable Battery Information UN2800 classification as "Batteries, wet, Non-Spillable, and electric storage" as a result of passing the Vibration and Pressure Differential Test described in DOT [49 CFR 173.159(d) and IATA/ICAO [Special Provision A67]. CAUTION To reduce the risks associated with environmental contamination and possible injury: The 12W transmitter utilizes the 2200RB rechargeable battery for the Max Output power level. This is a maintenance-free sealed lead (Pb)-acid battery. • Replace the battery if the acid solution leaks. • The batteries are not serviceable. • Do not disassemble batteries. • Do not remove vent caps. • Do not rest tools or cables on batteries. • Store lead-acid batteries with adequate ventilation. • Do not heat batteries above 140°F (60°C)) • Never recharge batteries in an unventilated, enclosed space. • Spent batteries must be treated as hazardous waste. Dispose of batteries and electronic components in accordance with all regulations. • Do not incinerate batteries. • Always remove/disconnect batteries when not in use or storing for long periods of time. Cleaning Instructions Use a soft damp cloth to clean the product and test leads if necessary. Locator Software Upgrades Locator software upgrades are periodically released and can be downloaded, free of charge, at www.3M.com/dynatel. Located under the Software section, the 2220M-Series software is titled 2220M-Series Locator PC Tools x.x.x (EXE x.xMB) . Once downloaded to your PC, double click the file and an auto- installer will install the PC Tool desktop software. Double click the Dynatel 2220M Series PC Tool kit icon on the desktop. Using the provided RS232 cable, or RS232-to-USB adapter cable, connect the RS232 port on the locator to the PC and turn the locator on. Click the Upgrade Software button in PC Tools to begin upgrade. Do not disconnect, or turn off, the locator while the upgrade is in progress. Wait until the software indicates that the installation was successful.
3M and Dynatel are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Track and Trace Solutions6801 River Place Blvd. Austin, TX 78726-9000 1-800-426-8688 www.3M.com/dynatel Please Recycle. Printed in USA. © 3M 2009. All Rights Reserved. 78-9000-0021-3-C This product is in accordance with the requirements of the European directive 99/5/EC. This is the EU symbol f or equipment that is covered under the W aste from Electr ical and Electronic Equipment (WEEE) directiv e per CENELEC Specification 5041. It indicates that certain products should not be discarded in the trash, but rather should be recycled. This applies to all electronic pluggab le and batter y powered product s. Statement of Conformity "Hereby, 3M declares that this Underground Locating Product is in compliance with the essential requirements and other revelent provisions of Directive 1999/5/EC." www.3m.com/market/telecom/access/conformity/