Home > 3M > Locator > 3M Advanced PipeCable Locator 2220M Operator Manual

3M Advanced PipeCable Locator 2220M Operator Manual

    Download as PDF Print this page Share this page

    Have a look at the manual 3M Advanced PipeCable Locator 2220M Operator Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 307 3M manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							3M™ Dynatel™ 
    Advanced Pipe/Cable Locator 2220M
    Operator Manual
    2220M with 3-Watt Transmitter
    2220M with 12-Watt Transmitter   
    (U.S. and International versions)
    March 2009
    78-9000-0021-3-C 
    						
    							Contents
    Safety Information ............................................................................... 4
    Introduction  ......................................................................................... 5
    Standard Equipment Packages  ...................................................... 6
    Optional 3M
    ™ Dynatel™ Accessories ............................................ 7
    Quick Start  ........................................................................................... 7
    3-Watt Transmitter Battery Installation  ........................................ 7
    3-Watt Transmitter Overview  ........................................................ 7
    12-Watt Transmitter Battery Installation  ...................................... 8
    12-Watt Transmitter Overview  ...................................................... 9
    Receiver Battery Installation  ....................................................... 10
    Receiver Overview  ...................................................................... 11
    Transmitter Operations  ...................................................................... 12
    Direct Connection  ....................................................................... 12
    3M
    ™ Dynatel™ Dyna-Coupler Clamp  ......................................... 12
    Induction Method  ........................................................................ 13
    Receiver Operations  .......................................................................... 14
    Initial Settings .............................................................................. 14
    Receiver Setup  ............................................................................. 14
    Line Locating Screen  .................................................................. 17
    Pipe and Cable Locating  ............................................................. 18
    Depth and Current  ....................................................................... 18
    Sonde Locating  ............................................................................ 19
    Sonde Locating Screen ................................................................ 19
    Pin-Pointing the Sonde  ................................................................ 20
    Specifications  ..................................................................................... 21
    Rechargeable Battery Information  .............................................. 22
    Cleaning Instructions  .................................................................. 23
    Locator Software Upgrades  ........................................................ 23
    Statement of Conformity  ............................................................. 23 
    						
    							Safety Information
    Please read, understand and follow all safety information contained 
    in these instructions prior to the use of the 3M™ Dynatel™ Advanced 
    Pipe/Cable Locator 2220M. Retain these instructions for future use.
    Intended Use:
    The Advanced Pipe/Cable Locator 2220M is used to identify the 
    placement of underground utility lines. The system must be installed 
    as specified in the Advanced Pipe/Cable Locator 2220M Operator 
    Manual. It has not been evaluated for other uses or locations. If this 
    equipment is used in a manner not specified by 3M, the protections 
    provided by the equipment may be impaired.
    Explanation of Signal Word Consequences:
      Warning: 
    Indicates hazardous situation which, if not avoided, could result in 
    death or serious injury.
     Caution:
    Indicates hazardous situation which, if not avoided, could result in 
    minor or moderate injury.
    Explanation of Product Safety Label Symbols:
     Do not throw away in normal trash
     Warning: Risk of electric shock 
    						
    							5
    Introduction
    Congratulations! You have just purchased one of the finest, most advanced 
    locating devices available today! When you choose a quality 3M™ Dynatel™ 
    Advanced Pipe/Cable Locator 2220M, you get outstanding performance 
    and reliability.
    The 2220M locator with the 3-watt transmitter is an excellent instrument for 
    tracing underground utilities. The 2220M provides one audio frequency for 
    locating long sections of cable and one radio frequency for tracing pipes that 
    may have high resistance insulators and rubber gaskets that are often found 
    in water and gas distribution systems. The 2220M also provides three sonde 
    locating frequencies.
    The 2220M locator with the 12-watt transmitter* option offers additional power 
    output levels for improved induction performance, 8K (low frequency) induction 
    for shallow facilities, such as risers, and an ohm-meter function for measuring 
    path resistance.
    * Output Power up to 12 Watts for the 12 Watt Transmitter is achieved using the 
    supplied external power source. 12 Watt Output Power varies by frequency, or is 
    limited to 1 Watt at 82 kHz on the U-Model using direct connection method. 
    						
    							6
    Standard Equipment Packages
    Model NumberIncluded in Equipment Package
    2220M-U3W 2220M Receiver
    3 Watt Transmitter
    Direct Connect Cable (Utility size clip 5/8" [15.8 mm])
    Ground Rod
    RS232 Serial Port Cable
    RS232-to-USB Adapter Cable
    Operator Manual
    Carrying Bag
    2220M-U3W-CPLR 2220M Receiver
    3 Watt Transmitter
    Direct Connect Cable (Utility size clip 5/8" [15.8 mm])
    4.5" (114 mm) Dyna-Coupler clamp
    Coupler Cable
    Ground Rod
    RS232 Serial Port Cable
    RS232-to-USB Adapter Cable
    Operator Manual
    Carrying Bag
    2220M-C3W-CPLR 2220M Receiver
    3 Watt Transmitter
    Direct Connect Cable (Telecom size clip 1/4" [6.4 mm])
    3" (76 mm) Dyna-Coupler clamp
    Coupler Cable
    Ground Rod
    RS232 Serial Port Cable
    RS232-to-USB Adapter Cable
    Operator Manual
    Carrying Bag
    2220M-UCU12W/RT 2220M Receiver
    12 Watt Transmitter* (See asterisk, page 5)
    Direct Connect Cable (Utility size clip 5/8" [15.8 mm])
    Direct Connect Cable (Telecom size clip 1/4" [6.4 mm])
    3" (76mm) Dyna-Coupler Clamp
    Ground Rod
    RS232 Serial Port Cable
    RS232-to-USB Adapter Cable
    2200RB Rechargeable Battery
    Cigarette Lighter Adapter Cable
    Operator Manual
    Carrying Bag
    2220M-ECU12W/RT 2220M Receiver (International Version)
    12 Watt Transmitter
    Direct Connect Cable (Utility size clip 5/8" [15.8 mm])
    Direct Connect Cable (Telecom size clip 1/4" [6.4 mm])
    3" (76mm) Dyna-Coupler Clamp
    Coupler Cable
    Ground Rod
    RS232 Serial Port Cable
    RS232-to-USB Adapter Cable
    2200RB Rechargeable Battery
    Cigarette Lighter Adapter Cable
    Operator Manual
    Carrying Bag 
    						
    							7
    Optional 3M™ Dynatel™ Accessories
    •	3" (76 mm) Dyna-Coupler Clamp 3001
    •	 4.5" (114 mm) Dyna-Coupler Clamp 4001
    •	 6" (150 mm) Dyna-Coupler Clamp 1196
    •	 Coupler Cable 9011
    •	 Direct Connect Leads (Small Telecom clips) 2892
    •	 Ground Extension Cable 9043
    •	 ADP 33kHz Sonde 3229
    Quick Start
    3-Watt Transmitter Battery Installation
    Insert 6 "C" cell alkaline batteries (LR14)
    3-Watt Transmitter Overview
    3 Dynatel™ 2220M
    Off On
    Frequency
    Output Level
    Hzƒ
    Induction Direction
    ➊➋
    ➎
    ➌➍
    1.   Power OFF / Battery Level Indicator – Press and hold.
    Display reads: 
    “OK” with solid tone = good 
     “LO” with pulsing tone = low 
     “- -” with no tone = replace
    2.    Power ON / Frequency Select – Powers on the unit. When pressed 
    repeatedly, it will cycle through the available frequency modes: 
      a. Single audio frequency - 8 kHz  
    						
    							8
    b.  Single radio frequency - 82 kHz
    c.   Dual frequency – Both 8 kHz and 82 kHz are transmitted simultaneously.
    3.    Output Level – Toggles the output power level between Normal Output and 
    High Output modes. Flag will fl ash over output icon on the LCD display 
    when in High Output mode. No fl ag is present when in Normal Output 
    mode.
    4.  Output Jack – Direct Connect and 3M
    ™ Dynatel™ Dyna-Coupler Clamp port.
    5.   Induction Direction Arrows – Indicates orientation of transmitter in 
    relationship to target path.
    12-Watt Transmitter Battery Installation
    Insert 6 "C" cell alkaline batteries (LR14) Additional rechargeable battery required 
    for 12-watt output 
    						
    							9
    12-Watt Transmitter Overview
    Induction Direction
     off
    +
    -o
     
    Frequency
    onon  Output Level
    DynatelTM222 0M
    ➋
    ➊➌
    ➐
    ➍➎➏
    1.    Power OFF / Battery Level Indicator – Press and hold.
    Display reads:
    “OK” with solid tone = good
     “LO” with pulsing tone = low
     “- -” with no tone = replace
    2.   Power ON / Ohm Meter Select – Powers on the unit. Places unit in ohm-
    meter mode for measurement of the trace circuit resistance.
    3.   Power ON / Frequency Select – Powers on the unit. When pressed 
    repeatedly, it will cycle through the available frequency modes:
     a.  Single audio frequency - 8 kHz
    b.  Single radio frequency - 82 kHz
    c.   Dual frequency – Both 8 kHz and 82 kHz are transmitted 
    simultaneously.
    4.    Output Level – Toggles the output power level between Normal, High and 
    Max Output modes. The fl ag will be solid over the output icon on the LCD 
    display when in High Output mode and will fl ash when in Max Output 
    mode. No fl ag is present when in Normal Output mode.
    NOTE: An external 12-volt power source is required to obtain the Max 
    Output mode. The 12-watt transmitter ships with a 12-volt rechargeable 
    battery and a cigarette lighter adapter cable to achieve this output level. 
    NOTE: 12 Watt Output Power varies by frequency, or is limited to 1 Watt at 
    82 kHz on the U-Model using direct connection method.
    5.  Output Jack – Direct Connect and 3M
    ™ Dynatel™ Dyna-Coupler Clamp port.
    6.    External Jack  - Port to connect cigarette lighter adapter cable or rechargeable 
    battery (2200 RB). Input voltage level: 9 - 18 VDC
    7.   Induction Direction Arrows – Indicates orientation of transmitter in 
    relationship to target path. 
    						
    							10
     Warning  
    To reduce the risk associated with hazardous voltage:
        •    Potential for electric shock exists when handling connection cables while 
    the transmitter is ON. Make all connections prior to powering on the unit. 
    Turn transmitter OFF before handling connection cables.
        •     Voltage greater than 240 volts will damage equipment and could cause 
    personal injury or death. Make all connections before turning on the trans -
    mitter. Follow standard procedures for reducing the voltage.
        • Do not modify this product in any way.
    Receiver Battery Installation
    Install 8 "AA" Alkaline batteries (LR6)
    The receiver displays the battery level across the bottom of the start up screen 
    when the unit is powered on.
      Caution 
    To reduce the risks associated with fire and explosion:
        •  Do not short, excessively heat or incinerate the batteries.
    To reduce the risks associated with environmental contamination:
        •     Dispose of batteries and electronic components in accordance with all 
    regulations.
        •  Insure batteries are installed with correct polarity.
        •  Always remove batteries when storing the unit for long periods of time. 
    						
    All 3M manuals Comments (0)