York Model Gy8s User Instructions
Here you can view all the pages of manual York Model Gy8s User Instructions. The York manuals for Furnace are available online for free. You can easily download all the documents as PDF.
Page 1
035-20465-001 Rev. A (0704) USER’S INFORMATION, MAINTENANCE AND SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES MODELS: GY8S / GM8S / LY8S / LM8S / LF8 (Single Stage Upflow / Horizontal / LoNOx) EFFICIENCY RATING CERTIFIED This product was manufactured in a plant whose quality system is certified/registered as being in conformity with ISO 9001. The manufacturer recommends that the user read all sec- tions of this manual and keep the manual for future refer- ence. SECTION I: USER’S...
Page 2
035-20465-001 Rev. A (0704) 2Unitary Products Group 7. NEVER . . .Store flammable materials of any kind near your fur- nace. Gasoline, solvents, and other volatile liquids should be stored only in approved containers outside your home. These materials vaporize easily and are extremely dangerous. 8. NEVER . . .Store cleaning materials near your furnace. Materials such as bleaches, detergents, powdered cleansers, etc., can cause corrosion of the heat exchangers. 9. NEVER . . . Use the area around your...
Page 3
035-20465-001 Rev. A (0704) Unitary Products Group3 HOW YOUR GAS FURNACE WORKS Your furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. For this reason, you may never have given much thought to the way your furnace operates. In order to get the safest and most efficient oper- ation from your furnace, you should understand how your furnace does its job. When you set your thermostat to provide more heat in your home, you...
Page 4
035-20465-001 Rev. A (0704) 4Unitary Products Group FURNACE USER MAINTENANCE Every time the filters are changed the following items should be visually inspected: • Check combustion air and vent pipe for blockage or leakage. • Check all components to be sure they are in good condition and that there are no obvious signs of deterioration. • Check the drain lines to make sure there are no cracks or leaks. • Check for dirt or lint on any surfaces or on components. Do not try to clean any of the surfaces or...
Page 5
035-20465-001 Rev. A (0704) Unitary Products Group5 SECTION II: SERVICE AND MAINTENANCE MANUAL SAFETY SECTION The following safety rules must be followed when servicing the furnace. FURNACE MAINTENANCE SECTION The furnace should be cleaned and adjusted by a certified dealer or qualified service contractor once a year or before the start of every heating season. The following items must be cleaned and serviced or replaced if there are signs of deterioration. 1. The vent terminal. 2. The furnace vent and...
Page 6
035-20465-001 Rev. A (0704) 6Unitary Products Group Intermittent Blower - Cooling Cooling/heating thermostats have a fan switch that has an ON and AUTO position. In the AUTO position the thermostat circuit is completed between terminals R and G when there is a call for cooling. The motor will operate on the speed tap wire that is connected to the “HI COOL” cooling terminal on the control board. The fan off setting is fixed at 60 seconds to improve cooling efficiency. Heating Cycle When the thermostat...
Page 7
035-20465-001 Rev. A (0704) Unitary Products Group7 2 RED FLASHES: This indicates that the normally open pressure switch contacts are stuck in the closed position. The control confirms these contacts are open at the beginning of each heat cycle. This would indicate a faulty pressure switch or miswiring. 3 RED FLASHES: This indicates the normally open pressure switch contact did not close after the inducer was energized. This could be caused by a number of problems: faulty inducer, blocked vent pipe,...
Page 8
035-20465-001 Rev. A (0704) 8Unitary Products Group SECTION III: REPLACEMENT PARTS LIST FIELD INSTALLED ACCESSORIES - NON-ELECTRICAL FIGURE 8: Furnace Control Event Schedule Thermostat Calling for HeatThermostat Satisfied (Seconds) THERMOSTAT INDUCER IGNITOR MAIN VALVE HUMIDIFIER ELECTRONIC AIR CLEANER CIRCULATING BLOWEROFF OFF OFF OFF OFF OFF OFF ON ON ON ONOFF OFF OFF OFFON ON ON OFF OFF OFFOFF OFF OFF OFF 15 Sec. Post Purge Fan on Delay 30 Seconds 0 2 17 2252 0 60, 90, 120, 180 SEC. Selectable Fan...
Page 9
035-20465-001 Rev. A (0704) Unitary Products Group9 27 3 30 265 10 92224112 29 8 23 12 7 17 19 21 13 1 16 154 4340 28 25 39 37 6,20 31 12A 7 3524 3612 19 11
Page 10
035-20465-001 Rev. A (0704) 10Unitary Products Group ITEM DESCRIPTION MOTOR 1MOTOR,DIRECT DRIVE BLOWER 2 MOTOR,VENTOR ASS’Y ELECTRICAL 3 CAPACITOR 4 CONTROL, HIGH LIMIT 5 CONTROL, FURACE 6IGNITER 7 SENSOR, FLAME 8 SWITCH, AIR PRESSURE [1LP] 9 SWITCH, DOOR [SW] 10 TRANSFORMER 11 VALVE, GAS 12 CONTROL, LIMIT (Top) 12ACONTROL, LIMIT (Side, 2 Req’d) 13CONTROL, AUX LIMIT (2 Req’d) 14* FUSE AIR MOVING 15 HOUSING, BLOWER 16 WHEEL, BLOWER 16A PANEL, FILLER WRAP FABRICATED PARTS 17 SHIELD,...