Page 61
61 MOTIF6 / MOTIF7 / MOTIF8 Measuring Requirements When testing the unit in the MANUAL or AUTO mode, the following Instruments and jigs are required: Instruments: Frequency Counter, Oscilloscope, Level Indicator (JIS-C curve), Distortion Meter (Flat), Oscillometer, Keyboard Amplifier, PLG100-VH, etc. Jigs: MIDI Cable, Proprietary Expansion Board, etc. A. Entering Test Mode Push Turn on power with the [REMOTE CONTROL ON/OFF] and [REC] buttons pressed and held. The following screen appears. Press [ENTER]...
Page 62
62MOTIF6 / MOTIF7 / MOTIF8 T03: LED Check Initial Screen: //// MOTIFx Test Program //// 03:LED :Press [ENTER] Description: This test turns LED’s in sequence, roughly every 0.5 sec. Make sure the LED’s normally operate and glow consis- tently. Procedure: Turn all the LED’s on the unit in sequence following the instructions below to make sure they all light up: //// MOTIFx Test Program //// 03:LED :Checking (xxxxxxx) xxxxxxx : LED Name When the LED’s stay on, sound a...
Page 63
63 MOTIF6 / MOTIF7 / MOTIF8 11 →12 →13 → 14 →15 →16 → MUTE * Only MOTIF6, 7 Check Item: Make sure all the switches operate normal. Display of Test Conclusion: OK //// MOTIFx Test Program //// 04:Panel SW :OK NG //// MOTIFx Test Program //// 04:Panel SW :Press [xxxxxxx] NG Ending Process: If all the switches are successfully tested, OK appears on the LCD, the test ends and returns to the item select status. For NG determined on the way of the test, see “C. Procedure for NG”. ∗...
Page 64
64MOTIF6 / MOTIF7 / MOTIF8 //// MOTIFx Test Program //// 07:Slider : Slider-1 : xxx Slider-2 : xxx Slider-3 : xxx Slider-4 :OK yyy : Target value xxx : Current value Display of Test Conclusion: OK //// MOTIFx Test Program //// 07:Slider :OK Slider-1 :OK Slider-2 :OK Slider-3 :OK Slider-4 :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T08: 1KeyOn Check Initial Screen:...
Page 65
65 MOTIF6 / MOTIF7 / MOTIF8 Display of Test Conclusion: OK //// MOTIFx Test Program //// 09:Keyboard + AT :OK Scaling :OK After Touch :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T10: PB, MW, BC Check Connect the breath controller before starting this test. Initial Screen: //// MOTIFx Test Program //// 10:PB,MW,BC :Press [ENTER] Description: Make sure “Pitch Bend, “Modulation Wheel” and “Breath Controller” operate...
Page 66
66MOTIF6 / MOTIF7 / MOTIF8 Check Item: Make sure IN and OUT are OK, and THRU outputs a test pattern. Display of Test Conclusion: OK //// MOTIFx Test Program //// 12:MIDI :OK NG //// MOTIFx Test Program //// 12:MIDI :NG If an unexpected data is received: //// MOTIFx Test Program //// 12:MIDI :NG TIME OUT If the reception does not complete within a certain time: Ending Process: The test ends after displaying the test conclusion and enters the item selection status....
Page 67
67 MOTIF6 / MOTIF7 / MOTIF8 T15: 1 kHz OUTPUT R Check Initial Screen: //// MOTIFx Test Program //// 15:OUTPUT-R :Press [ENTER] Procedure: Insert plugs into OUTPUT-L, OUTPUT-R, Assignable-L, Assignable-R, PHONES (L) and PHONES (R) to monitor the frequencies, output waveforms and output levels using a frequency counter, oscilloscope and level indicator (with JIS_C filters). Set Master Volume to max. When sounding, the LCD displays as follows: //// MOTIFx Test Program //// 15:OUTPUT-R...
Page 68
68MOTIF6 / MOTIF7 / MOTIF8 T18: CARD (WRITE/READ) Check Initial Screen: //// MOTIFx Test Program //// 18:Card :Press [ENTER] Description: Make sure the Smart Media is protected. Checks the Format, Write, Read and Verify on the Smart Media. Make sure the Smart Media is removable. Procedure: First, insert a protected Smart Media into the slot and run the test. Then, insert a not-protected Smart Media into the slot and run the test. Run the test without a Smart Media inserted. Check Item:...
Page 69
69 MOTIF6 / MOTIF7 / MOTIF8 Error code : NG_BOARD: Board other than VH is inserted. NO_BOARD: No board (No board is inserted) MIDI: MIDI LINE faulty Ending Process: Press [EXIT] button once to stop sounding, twice to determine OK or NG or three times to enter the status waiting for a test number. T21: Plug-In 2 Check Initial Screen: //// MOTIFx Test Program //// 21:PLG2 :Press [ENTER] Description: Checks for connection at Plug-in Slot 2, sending/reception through Control Line, MIDI Line...
Page 70
70MOTIF6 / MOTIF7 / MOTIF8 Procedure: Loop between the AIEB1 Digital input and output to sound a sine wave to the Digital output. Make sure the following level outputs are sent out from the ChStatus, and Outputs R and L. //// MOTIFx Test Program //// 23:Digital In :ON Ch Status :xx xx : OK/NG Check Item: Ch Status: OK/NG OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) Display of Test Conclusion: NG //// MOTIFx Test Program ////...