– 6– 4 6 2 5 WARNINGq 8Read the owner’s manual and all labels before operating.8Only operate in well-ventilated areas. Exhaust gas contains poisonous carbon monoxide. 8Check for spilled fuel or fuel leaks. 8Stop engine before refueling. 8Do not operate near flammable materials. 8Electrocution can occur if generator is used in rain, snow, or near water. Keep this unit dry at all times. 8Electrocution or property damage can occur: Do not connect this generator to any building’s electrical system unless an isolation switch has been installed by a licensed electrician. Refer to the owner’s manual. 8When operating the generator: Never place a partition or other barrier around the generator. Do not cover the generator with a box. Do not place any objects on the generator. 7DK-24162-10 The air index of this engine is 3(California only) MOST CLEAN LEAST CLEAN0246810 Note: The lower the air index, the less the pollution.This engine is certified to be emissions compliantfor the following use: Check owners manual for further details.( *** HOURS) ( *** HOURS) ( *** HOURS)MODERATE INTERMEDIATE EXTENDEDX EMISSION CONTROL INFORMATIONYAMAHA MOTOR POWERED PRODUCTS CO., LTD. emission regulations for small off-road engines. This engine meets 20** California exhaust and evaporativeTHIS ENGINE MEETS U.S. EPA EXHEVP REGS FOR 20**. EVAP F: ******** EF: *********** EMISSION CONTROL SYSTEM: ** DISPLACEMENT: *** cc EMISSION COMPLIANCE PERIOD : *** HOURS This engine is certified to operate on unleaded gasoline. No other adjustments needed. ENGINE OIL: SAE***** TYPE : ** HOT EXHAUST7WL-28176-10 3 NOTICE Use the specified spark plug only. Specified plug:BPR6HS(NGK) 7DK-24164-10 OILEF2000IS YAMAHA MOTOR POWERED PRODUCTS CO.,LTD.MADE IN JAPAN AC output 60Hz Rated 1.6kVA 120V Phase Single DC output 12V 8A Fuel Gasoline 7DK-9-11_a 11.3.21 15:19 Page 6
– 7– 1 2 3 4 7DK-015 DESCRIPTION 1Carrying handle 2Fuel tank cap air vent knob 3Fuel tank cap 4Recoil starter 5Fuel gauge 6Muffler 7Oil filler cap AE00103 Control panel 1Oil warning light 2AC pilot light 3Overload indicator light 4Economy control switch (Black) 5Engine switch (Red) 6Fuel cock knob 7Choke knob 8Twin Tech (parallel running terminal) 9AC receptacle 0DC protector (breaker) qGround (earth) terminal wDC receptacle 123 45 6 7 8 9 0 q w 7DK-017 7DK-016 7DK-9-11_a 11.3.21 15:19 Page 7
– 8– 12 7DK-018 700-115 AE00111 Oil warning light (Red) When the oil level falls below the lower level, the oil warning light comes on and then the engine stops auto- matically. Unless you refill with oil, the engine will not start again. TIP If the engine stalls or does not start, turn the engine switch to “ON”and then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil is insufficient. Add oil and restart. AE00101 CONTROL FUNCTION AE00121 Engine switch The engine switch controls the ignition system. 17“ON” Ignition circuit is switched on. The engine can be started. 25“STOP” Ignition circuit is switched off. The engine will not run. DC protector The DC protector turns off 2automatically when elec- tric device being connected to the generator is operat- ing and current above the rated flows. To use this equip- ment again, turn on the DC protector by pressing its button to “ON”1. 1 27DK-052 1“ON” Direct current is output. (This is the default position.) 2“OFF” Direct current is not output. 7DK-9-11_a 11.3.21 15:19 Page 8
– 9– AE00142 Economy control switch 1I “ON” When the economy control switch is turned to “ON”1, the economy control unit controls the engine speed according to the connected load. The results are better fuel consumption and less noise. 23“OFF” When the economy control switch is turned to “OFF”2, the engine runs at the rated r/min (4,500 r/min) regard- less of whether is a load connected or not. TIP The economy control switch must be turned to “OFF”2 when using electric devices that require a large starting current, such as a compressor of a submersible pump. AC pilot light (Green) The AC pilot light 1comes on when the engine starts and produces power. 12 7DK-020 1 7DK-048 Reduce the load of the connected electric device below the specified rated output of the generator if the DC protector turns off. If the DC protector turns off again, stop using the device immediately and consult a Yamaha dealer. NOTICE 7DK-9-11_a 11.3.21 15:19 Page 9
– 10– AE01087 Overload indicator light (Red) The overload indicator light 1comes on when an over- load of a connected electrical device is detected, the inverter control unit overheats, or the AC output voltage rises. Then, the AC protector will trip, stopping power generation in order to protect the generator and any connected electric devices. The AC pilot light (Green) will go off and the overload indicator light (Red) will stay on, but the engine will not stop running. When the overload indicator light comes on and power generation stops, proceed as follows: 1. Turn off any connected electric devices and stop the engine. 2. Reduce the total wattage of connected electric devices within the rated output. 3. Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove them. 4. After checking, restart the engine. TIP The overload indicator light may come on for a few sec- onds at first when using electric devices that require a large starting current, such as a compressor or a sub- mersible pump. However, this is not a malfunction. 1 7DK-021 7DK-022 Fuel tank cap Remove the fuel tank cap by turning it counterclock- wise. 7DK-9-11_a 11.3.21 15:19 Page 10
– 11– 12 7DK-023 2 1 7DK-024 1 7DK-011 Fuel cock knob The fuel cock supplies fuel from the fuel tank to the car- buretor. The fuel cock has two positions. 1“ON” With the knob in this position, fuel flows to the carbure- tor. Normal using is done with the knob in this position. 2“OFF” With the knob in this position, fuel will not flow. Always turn the knob to this position when the engine is not running. Ground (earth) terminal Ground (earth) terminal 1connects the earth line for prevention of electric shock. When the electric device is grounded, be sure to ground the generator also. 7DK-042a Twin Tech (Terminal for Connecting special cables for parallel running) This is the terminal for connecting special cables for parallel running of two EF2000iS. The parallel running requires two EF2000iS and the special cables. (The rated output in parallel running is 3.0 kVA and the rated current is 25.0 A.) The handling, operation procedure and the notes on usage are described in the PARALLEL RUNNING KIT OWNER’S MANUAL included in the Parallel Running Kit. Consult a Yamaha dealer for this Parallel Running Kit. Fuel tank cap air vent knob The fuel tank cap 2is provided with an air vent knob 1to stop fuel flow. The air vent knob must be turned to “ON”. This will allow fuel to flow to the carburetor and the engine to run. When the engine is not in use, turn the air vent knob to “OFF”to stop fuel flow. 7DK-9-11_a 11.3.21 15:19 Page 11
– 12– Remove the fuel tank cap and fill the fuel into the tank up to the red level 2. The fuel level in the fuel tank can be checked through the fuel level gauge 1. 1Fuel level gauge 2Red line 3Fuel level Your Yamaha engine has been designed to use regular unleaded gasoline with a pump octane number ((R + M)/2) of 86 or higher, or research octane number of 91 or higher. 7DK-026 127DK-037 7DK-091 3 7DK-028 4 5 7DK-093 707-095 PREPARATION AE00856 Fuel 9Fuel is highly flammable and poisonous. Check “SAFETY INFORMATION”(See page 2) careful- ly before filling. 9Do not overfill the fuel tank, otherwise it may overflow when the fuel warms up and expands. 9After fill the fuel, make sure the fuel tank cap is tightened securely. 9Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may deteriorate paint- ed surfaces or plastic parts. 9Use only unleaded gasoline. The use of leaded gasoline will cause severe damage to internal engine parts. NOTICE WARNING Recommended fuel: Unleaded gasoline Fuel tank capacity: Total: 4.2 L (1.11 US gal, 0.92 Imp gal) 4“F”Full 5“E”Empty 7DK-9-11_a 11.3.21 15:19 Page 12
– 13– 1Upper level 5. Install the cover and tighten the screws. 7DK-031 1 7DK-033 700-119 1 AE00222 Engine oil The generator has been shipped without engine oil. Do not start the engine until you have filled it with the sufficient engine oil. 1. Place the generator on a level surface. 2. Remove the screws 1, and then remove the cover 2. NOTICE 7DK-030 4. Fill the specified amount of the recommended engine oil, and then install and tighten the oil filler cap. Recommended engine oil: åYAMALUBE 4 (10W-40), SAE 10W-30 or 10W-40 ∫SAE #30çSAE #20∂SAE 10W Recommended engine oil grade: API Service SE type or higher Engine oil quantity: 0.4 L (0.42 US qt, 0.35 lmp qt)0°C å YAMALUBE 4 (10W-40) ∂ SAE 10Wç SAE #20∫ SAE #30 32°F25°C 80°F 3. Remove the oil filler cap 1. 7DK-9-11_a 11.3.21 15:19 Page 13
– 14– AE00845 PRE-OPERATION CHECK If any item in the Pre-operation check is not work- ing properly, have it inspected and repaired before operating the generator. The condition of a generator is the owners responsibil- ity. Vital components can start to deteriorate quickly and unexpectedly, even if the generator is unused. TIP Pre-operation checks should be made each time the generator is used. Pre-operation check Fuel (See page 12) 9Check fuel level in fuel tank. 9Refuel if necessary. Fuel line 9Check fuel hose for crack or damage. 9Replace if necessary. Engine oil (See page 13) 9Check oil level in engine. 9If necessary, add recommended oil to specified level. 9Check generator for oil leakage. The point where abnormality was recognized by use 9Check operation. 9If necessary, consult a Yamaha dealer. WARNING 7DK-9-11_a 11.3.21 15:19 Page 14
– 15– 7DK-047 1 7DK-038 AE00846 OPERATION 9Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Operate the engine in a well venti- lated area. 9Before starting the engine, do not connect any electric devices. 9Clean dusts, dirt or water off the receptacle before use. The generator has been shipped without engine oil. Do not start the engine until you have filled it with the sufficient engine oil. NOTICE WARNING Starting the engine 1. Turn the economy control switch (Black) to “OFF” 1. 13“OFF”1 7DK-034 1 7DK-035 3. Turn the fuel cock knob to “ON”1. 1“ON” 2. While holding the fuel tank cap so that it will not move, turn the air vent knob to “ON”1. 1“ON” 7DK-9-11_a 11.3.21 15:19 Page 15