Home > Yamaha > Generator > Yamaha Ef2000is 2 Manual

Yamaha Ef2000is 2 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Yamaha Ef2000is 2 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 255 Yamaha manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							– 6–
    4
    6 2
    5
    WARNINGq
    8Read the owner’s manual and all labels before operating.8Only operate in well-ventilated areas. Exhaust gas contains poisonous carbon monoxide.
    8Check for spilled fuel or fuel leaks.
    8Stop engine before refueling.
    8Do not operate near flammable materials.
    8Electrocution can occur if generator is used in rain, snow, or near water. Keep this unit dry at all times.
    8Electrocution or property damage can occur: Do not connect this generator to any building’s electrical
    system unless an isolation switch has been installed by a licensed electrician. Refer to the owner’s manual.
    8When operating the generator:
    Never place a partition or other barrier around the generator.
    Do not cover the generator with a box.
    Do not place any objects on the generator.
    7DK-24162-10
    The air index of this engine is 3(California only)
    MOST CLEAN LEAST CLEAN0246810
    Note: The lower the air index, the less the pollution.This engine is certified to be emissions compliantfor the following use:
    Check owners manual for further details.(  *** HOURS) (  *** HOURS) (  *** HOURS)MODERATE INTERMEDIATE EXTENDEDX
    EMISSION CONTROL INFORMATIONYAMAHA MOTOR POWERED PRODUCTS CO., LTD.
    emission regulations for small off-road engines. This engine meets  20**  California exhaust and evaporativeTHIS ENGINE MEETS U.S. EPA EXHEVP REGS FOR 20**.
    EVAP F: ******** EF: ***********
    EMISSION CONTROL SYSTEM: ** DISPLACEMENT:   ***  cc
    EMISSION COMPLIANCE PERIOD :  ***  HOURS
    This engine is certified to operate on unleaded gasoline.
    No other adjustments needed. ENGINE OIL: SAE*****  TYPE : **
    HOT  EXHAUST7WL-28176-10
    3
    NOTICE
    Use the specified spark plug only.
    Specified plug:BPR6HS(NGK)
    7DK-24164-10
    OILEF2000IS
    YAMAHA MOTOR POWERED PRODUCTS CO.,LTD.MADE IN JAPAN
    AC output          60Hz
          Rated          1.6kVA
                             
     120V
          Phase          Single
    DC output         12V 8A
    Fuel                   Gasoline
     7DK-9-11_a  11.3.21 15:19  Page 6 
    						
    							– 7–
    1
    2
    3
    4
    7DK-015
    DESCRIPTION
    1Carrying handle
    2Fuel tank cap air vent knob
    3Fuel tank cap
    4Recoil starter
    5Fuel gauge
    6Muffler
    7Oil filler cap
    AE00103
    Control panel
    1Oil warning light
    2AC pilot light
    3Overload indicator light
    4Economy control switch
    (Black)
    5Engine switch (Red)
    6Fuel cock knob
    7Choke knob
    8Twin Tech (parallel running
    terminal)
    9AC receptacle
    0DC protector (breaker)
    qGround (earth) terminal
    wDC receptacle
    123 45
    6
    7
    8
    9
    0 q w
    7DK-017
    
    
    
    7DK-016
     7DK-9-11_a  11.3.21 15:19  Page 7 
    						
    							– 8–
    12
    7DK-018
    700-115
    AE00111
    Oil warning light (Red)
    When the oil level falls below the lower level, the oil
    warning light comes on and then the engine stops auto-
    matically. Unless you refill with oil, the engine will not
    start again.
    TIP
    If the engine stalls or does not start, turn the engine
    switch to “ON”and then pull the recoil starter. If the oil
    warning light flickers for a few seconds, the engine oil is
    insufficient. Add oil and restart.
    AE00101
    CONTROL FUNCTION
    AE00121
    Engine switch
    The engine switch controls the ignition system.
    17“ON”
    Ignition circuit is switched on.
    The engine can be started.
    25“STOP”
    Ignition circuit is switched off.
    The engine will not run.
    DC protector
    The DC protector turns off 2automatically when elec-
    tric device being connected to the generator is operat-
    ing and current above the rated flows. To use this equip-
    ment again, turn on the DC protector by pressing its
    button to “ON”1.
    1
    27DK-052
    1“ON”
    Direct current is output. (This is the default position.)
    2“OFF”
    Direct current is not output.
     7DK-9-11_a  11.3.21 15:19  Page 8 
    						
    							– 9–
    AE00142
    Economy control switch
    1I  “ON”
    When the economy control switch is turned to “ON”1,
    the economy control unit controls the engine speed
    according to the connected load. The results are better
    fuel consumption and less noise.
    23“OFF”
    When the economy control switch is turned to “OFF”2,
    the engine runs at the rated r/min (4,500 r/min) regard-
    less of whether is a load connected or not.
    TIP
    The economy control switch must be turned to “OFF”2
    when using electric devices that require a large starting
    current, such as a compressor of a submersible pump.
    AC pilot light (Green)
    The AC pilot light 1comes on when the engine starts
    and produces power.
    12
    7DK-020
    1
    7DK-048
    Reduce the load of the connected electric device
    below the specified rated output of the generator if
    the DC protector turns off. If the DC protector turns
    off again, stop using the device immediately and
    consult a Yamaha dealer.
    NOTICE
     7DK-9-11_a  11.3.21 15:19  Page 9 
    						
    							– 10–
    AE01087
    Overload indicator light (Red)
    The overload indicator light 1comes on when an over-
    load of a connected electrical device is detected, the
    inverter control unit overheats, or the AC output voltage
    rises. Then, the AC protector will trip, stopping power
    generation in order to protect the generator and any
    connected electric devices. The AC pilot light (Green)
    will go off and the overload indicator light (Red) will stay
    on, but the engine will not stop running.
    When the overload indicator light comes on and power
    generation stops, proceed as follows:
    1. Turn off any connected electric devices and stop
    the engine.
    2. Reduce the total wattage of connected electric
    devices within the rated output.
    3. Check for blockages in the cooling air inlet and
    around the control unit. If any blockages are found,
    remove them.
    4. After checking, restart the engine.
    TIP
    The overload indicator light may come on for a few sec-
    onds at first when using electric devices that require a
    large starting current, such as a compressor or a sub-
    mersible pump. However, this is not a malfunction.
    1
    7DK-021
    7DK-022
    Fuel tank cap
    Remove the fuel tank cap by turning it counterclock-
    wise.
     7DK-9-11_a  11.3.21 15:19  Page 10 
    						
    							– 11–
    12
    7DK-023
    2 1
    7DK-024
    1
    7DK-011
    Fuel cock knob
    The fuel cock supplies fuel from the fuel tank to the car-
    buretor.
    The fuel cock has two positions.
    1“ON”
    With the knob in this position, fuel flows to the carbure-
    tor. Normal using is done with the knob in this position.
    2“OFF”
    With the knob in this position, fuel will not flow. Always
    turn the knob to this position when the engine is not
    running.
    Ground (earth) terminal
    Ground (earth) terminal 1connects the earth line for
    prevention of electric shock.
    When the electric device is grounded, be sure to
    ground the generator also.
    7DK-042a
    Twin Tech
    (Terminal for Connecting special cables for
    parallel running)
    This is the terminal for connecting special cables for
    parallel running of two EF2000iS. The parallel running
    requires two EF2000iS and the special cables. (The
    rated output in parallel running is 3.0 kVA and the rated
    current is 25.0 A.)
    The handling, operation procedure and the notes on
    usage are described in the PARALLEL RUNNING KIT
    OWNER’S MANUAL included in the Parallel Running
    Kit. Consult a Yamaha dealer for this Parallel Running
    Kit.
    Fuel tank cap air vent knob
    The fuel tank cap 2is provided with an air vent knob
    1to stop fuel flow.
    The air vent knob must be turned to “ON”. This will
    allow fuel to flow to the carburetor and the engine to
    run. When the engine is not in use, turn the air vent
    knob to “OFF”to stop fuel flow.
     7DK-9-11_a  11.3.21 15:19  Page 11 
    						
    							– 12–
    Remove the fuel tank cap and fill the fuel into the tank
    up to the red level 2.
    The fuel level in the fuel tank can be checked through
    the fuel level gauge 1.
    1Fuel level gauge
    2Red line
    3Fuel level
    Your Yamaha engine has been designed to use regular
    unleaded gasoline with a pump octane number ((R +
    M)/2) of 86 or higher, or research octane number of 91
    or higher.
    7DK-026
    127DK-037
    7DK-091
    3
    7DK-028
    4
    5
    7DK-093
    707-095
    PREPARATION
    AE00856
    Fuel
    9Fuel is highly flammable and poisonous. Check
    “SAFETY INFORMATION”(See page 2) careful-
    ly before filling.
    9Do not overfill the fuel tank, otherwise it may
    overflow when the fuel warms up and expands.
    9After fill the fuel, make sure the fuel tank cap is
    tightened securely.
    9Immediately wipe off spilled fuel with a clean,
    dry, soft cloth, since fuel may deteriorate paint-
    ed surfaces or plastic parts.
    9Use only unleaded gasoline. The use of leaded
    gasoline will cause severe damage to internal
    engine parts.
    NOTICE
    WARNING
    Recommended fuel:
    Unleaded gasoline
    Fuel tank capacity:
    Total:
    4.2 L (1.11 US gal, 0.92 Imp gal)
    4“F”Full
    5“E”Empty
     7DK-9-11_a  11.3.21 15:19  Page 12 
    						
    							– 13– 1Upper level
    5. Install the cover and tighten the screws.
    7DK-031
    1
    7DK-033
    700-119
    1
    AE00222
    Engine oil
    The generator has been shipped without engine oil.
    Do not start the engine until you have filled it with
    the sufficient engine oil.
    1. Place the generator on a level surface.
    2. Remove the screws 1, and then remove the cover
    2.
    NOTICE
    
    
    7DK-030
    4. Fill the specified amount of the recommended
    engine oil, and then install and tighten the oil filler
    cap.
    Recommended engine oil:
    åYAMALUBE 4 (10W-40), 
    SAE 10W-30 or 10W-40
    ∫SAE #30çSAE #20∂SAE 10W
    Recommended engine oil grade:
    API Service SE type or higher
    Engine oil quantity:
    0.4 L (0.42 US qt, 0.35 lmp qt)0°C
    å
     YAMALUBE 4 (10W-40)
    ∂
     SAE 10Wç
     SAE #20∫
     SAE #30
    32°F25°C
    80°F
    3. Remove the oil filler cap 1.
     7DK-9-11_a  11.3.21 15:19  Page 13 
    						
    							– 14–
    AE00845
    PRE-OPERATION CHECK
    If any item in the Pre-operation check is not work-
    ing properly, have it inspected and repaired before
    operating the generator.
    The condition of a generator is the owners responsibil-
    ity. Vital components can start to deteriorate quickly
    and unexpectedly, even if the generator is unused.
    TIP
    Pre-operation checks should be made each time the
    generator is used.
    Pre-operation check
    Fuel (See page 12)
    9Check fuel level in fuel tank.
    9Refuel if necessary.
    Fuel line
    9Check fuel hose for crack or damage.
    9Replace if necessary.
    Engine oil (See page 13)
    9Check oil level in engine.
    9If necessary, add recommended oil to specified
    level.
    9Check generator for oil leakage.
    The point where abnormality was recognized by
    use
    9Check operation.
    9If necessary, consult a Yamaha dealer.
    WARNING
     7DK-9-11_a  11.3.21 15:19  Page 14 
    						
    							– 15–
    7DK-047
    1
    7DK-038
    AE00846
    OPERATION
    9Never operate the engine in a closed area or it
    may cause unconsciousness and death within
    a short time. Operate the engine in a well venti-
    lated area.
    9Before starting the engine, do not connect any
    electric devices.
    9Clean dusts, dirt or water off the receptacle
    before use.
    The generator has been shipped without engine oil.
    Do not start the engine until you have filled it with
    the sufficient engine oil.
    NOTICE
    WARNING
    Starting the engine
    1. Turn the economy control switch (Black) to “OFF”
    1.
    13“OFF”1
    7DK-034
    1
    7DK-035
    3. Turn the fuel cock knob to “ON”1.
    1“ON”
    2. While holding the fuel tank cap so that it will not
    move, turn the air vent knob to “ON”1.
    1“ON”
     7DK-9-11_a  11.3.21 15:19  Page 15 
    						
    All Yamaha manuals Comments (0)