Page 1
OPERATING MANUAL VERTEX STANDARD CO., LTD.4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARDUS Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V.P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD.Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. VERTEX STANDARD HK LTD.Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong
Page 2
Introduction.......................................... 1 Supplied Accessories .................................. 1 Available Option ......................................... 1 Front Panel Controls & Switches ........ 2 Rear Panel Connections....................... 6 Installation............................................. 8 Power connections ...................................... 8 Antenna considerations ............................... 9 Basic Operation .................................. 14...
Page 3
VR-5000 OPERATING MANUAL1 The VR-5000 is a communications receiver providing general coverage reception from 100 kHz to 2600 MHz on the CW, SSB (LSB and USB), AM, and FM (Wide and Narrow bandwidths) modes (this coverage includes the AM and FM broadcast bands, HF Short- wave Bands up to 16 MHz, VHF and UHF TV bands, the VHF AM aircraft band, and a wide range of commercial and public safety frequencies!). Installation of the VR-5000 for everyday operation is may be accomplished in minutes. However, care...
Page 4
VR-5000 OPERATING MANUAL2 PS1 7 42 8 53 9 6ENT 0. MODE COPY DSP BANK CLR PMS SCAN B S M/SSUB SET PWR BS SET BS STEP M-S SCAN PMS SET PRI CLR DIMVCS SPL ADRSATT PRI LOCK BEEPSET S.CALL S.SRCH N B TIMER RF TUNE STEP V / MM W REC PLAY Front Panel Controls & Switches MAIN VOL/SQL Knob MAIN VOL Knob The inner MAIN VOL knob adjusts the audio volume of the MAIN receiver in the speaker or headphones. SQL Knob The outer SQL knob sets the signal level threshold at which MAIN receiver audio is muted (and the...
Page 5
VR-5000 OPERATING MANUAL3 Front Panel Controls & Switches PWR Knob This is the main on/off switch for the VR-5000. Press and hold this switch for one second to toggle the receiver’s power on and off. LCD (Liquid Crystal Display) The upper half of the display consists of a dot-matrix display for frequency readout, plus various icons representing enabled receiver features. The lower half contains a dot-matrix display for Band Scope viewing, menu pro- gramming, and alpha numeric name display, etc. Main...
Page 6
VR-5000 OPERATING MANUAL4 [ WIDTH( BS STEP)] Key Press this key momentarily to select the Band Scope sweep width. Press this key after [F] key is pressed (when the Band Scope is activated) to select the Band Scope sweeping step size. [ SCAN( M-S SCAN)] Key Press this key momentarily to activate the scanning function. Press this key after [F] key is pressed to activate the “M-S Scanning” feature. M-S Scan: The scanner hops back and forth between the MAIN VFO frequency and SUB VFO frequency. [ PMS( PMS...
Page 7
VR-5000 OPERATING MANUAL5 [ STEP( PLAY)] Key Press this key momentarily to select the synthesizer steps to be used during VFO op- eration. Press this key after [F] key is pressed to initiate playback on the voice recorder. [ V/M( MW)] Key Press this key momentarily to change the frequency control method between the VFO and the Memory systems. Press this key after [F] key is pressed to initiate the memory storage process. [ BANK] Key Press this key momentarily to select the desired memory bank. (...
Page 8
VR-5000 OPERATING MANUAL6 DC 13.5V Jack This is the DC power supply connection for the VR-5000. Connect the Supplied PA - 28 AC adapter to this jack. MUTE Jack If using the VR-5000 with a transceiver, shorting this jack during transmit will mute receiver output and attenuate the RF signal input. Check the information provided with your particular transceiver for details regarding proper connection. ANT B Terminal Use these spring-loaded terminal connectors to connect a high-impedance antenna. ANT...
Page 9
VR-5000 OPERATING MANUAL7 EXT SP Jack This 2-contact mini phone jack provides receiver audio for an external loudspeaker with an impedance of 4 ~ 16 Ω. Inserting a plug in this jack disables the loudspeaker. REC Jack This jack provides a constant level (8 mV @ 1 kΩ) audio output, which is unaffected by the VOL and TONE controls. This audio can be used for tape-recording purposes, and for connection to data demodulator/decoder equipment. +8V Jack This output jack provides 8V DC at up to 100 mA for...
Page 10
VR-5000 OPERATING MANUAL8 Installation PHYSICAL LOCATION OF THE RECEIVER The VR-5000 should be located in a place that allows unobstructed ventilation around the cabinet. Although the VR-5000 does not produce significant amounts of heat, as with any electronic device a well-ventilated location will ensure that heat does not build up inside the cabinet. Do not place the VR-5000 on top of another heat-generating device, and keep its top cover free of books, papers, and other objects which might impede...