Home > Yaesu Musen > Communications receiver > Yaesu Musen Yaesu Vr 5000 Communications Reciever Operating Manual

Yaesu Musen Yaesu Vr 5000 Communications Reciever Operating Manual

Here you can view all the pages of manual Yaesu Musen Yaesu Vr 5000 Communications Reciever Operating Manual. The Yaesu Musen manuals for Communications receiver are available online for free. You can easily download all the documents as PDF.

Page 1

OPERATING MANUAL
VERTEX STANDARD CO., LTD.4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARDUS Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong 

Page 2

Introduction.......................................... 1
Supplied Accessories .................................. 1
Available Option ......................................... 1
Front Panel Controls & Switches ........ 2
Rear Panel Connections....................... 6
Installation............................................. 8
Power connections ...................................... 8
Antenna considerations ............................... 9
Basic Operation .................................. 14...

Page 3

VR-5000 OPERATING MANUAL1
The VR-5000 is a communications receiver providing general coverage reception from
100 kHz to 2600 MHz on the CW, SSB (LSB and USB), AM, and FM (Wide and Narrow
bandwidths) modes (this coverage includes the AM and FM broadcast bands, HF Short-
wave Bands up to 16 MHz, VHF and UHF TV bands, the VHF AM aircraft band, and a
wide range of commercial and public safety frequencies!).
Installation of the VR-5000 for everyday operation is may be accomplished in minutes.
However, care...

Page 4

VR-5000 OPERATING MANUAL2
PS1
7 42
8 53
9 6ENT
0.
MODE
COPY
DSP
BANK
CLR PMS SCAN
B S M/SSUB SET PWR
BS SET BS STEP M-S SCAN PMS SET PRI CLR DIMVCS SPL
ADRSATT
PRI LOCK
BEEPSET
S.CALL S.SRCH
N B TIMER RF TUNE
STEP
V / MM W
REC
 PLAY
Front Panel Controls & Switches
 MAIN VOL/SQL Knob
MAIN VOL Knob
The inner MAIN VOL knob adjusts the audio volume of the MAIN receiver in the
speaker or headphones.
SQL Knob
The outer SQL knob sets the signal level threshold at which MAIN receiver audio is
muted (and the...

Page 5

VR-5000 OPERATING MANUAL3
Front Panel Controls & Switches
 PWR Knob
This is the main on/off switch for the VR-5000. Press and hold this switch for one
second to toggle the receiver’s power on and off.
 LCD (Liquid Crystal Display)
The upper half of the display consists of a dot-matrix display for frequency readout,
plus various icons representing enabled receiver features.
The lower half contains a dot-matrix display for Band Scope viewing, menu pro-
gramming, and alpha numeric name display, etc.
Main...

Page 6

VR-5000 OPERATING MANUAL4
[
WIDTH(
BS STEP)]
 Key
Press this key momentarily to select the Band Scope sweep width.
Press this key after [F] key is pressed (when the Band Scope is activated) to select
the Band Scope sweeping step size.
[
SCAN(
M-S SCAN)]
 Key
Press this key momentarily to activate the scanning function.
Press this key after [F] key is pressed to activate the “M-S Scanning” feature.
M-S Scan: The scanner hops back and forth between the MAIN VFO frequency and
SUB VFO frequency.
[
PMS(
PMS...

Page 7

VR-5000 OPERATING MANUAL5
[
STEP(
PLAY)]
 Key
Press this key momentarily to select the synthesizer steps to be used during VFO op-
eration.
Press this key after [F] key is pressed to initiate playback on the voice recorder.
[
V/M(
MW)]
 Key
Press this key momentarily to change the frequency control method between the VFO
and the Memory systems.
Press this key after [F] key is pressed to initiate the memory storage process.
[
BANK]
 Key
Press this key momentarily to select the desired memory bank.
	 (...

Page 8

VR-5000 OPERATING MANUAL6
 DC 13.5V Jack
This is the DC power supply connection for the VR-5000. Connect the Supplied PA -
28 AC adapter to this jack.
 MUTE Jack
If using the VR-5000 with a transceiver, shorting this jack during transmit will mute
receiver output and attenuate the RF signal input. Check the information provided with
your particular transceiver for details regarding proper connection.
 ANT B Terminal
Use these spring-loaded terminal connectors to connect a high-impedance antenna.
 ANT...

Page 9

VR-5000 OPERATING MANUAL7
 EXT SP Jack
This 2-contact mini phone jack provides receiver audio for an external loudspeaker
with an impedance of 4 ~ 16 Ω. Inserting a plug in this jack disables the loudspeaker.
 REC Jack
This jack provides a constant level (8 mV @ 1 kΩ) audio output, which is unaffected
by the VOL and TONE controls. This audio can be used for tape-recording purposes,
and for connection to data demodulator/decoder equipment.
 +8V Jack
This output jack provides 8V DC at up to 100 mA for...

Page 10

VR-5000 OPERATING MANUAL8
Installation
PHYSICAL LOCATION OF THE RECEIVER
The VR-5000 should be located in a place that allows unobstructed ventilation around the
cabinet. Although  the VR-5000 does not produce significant amounts of heat, as with any
electronic device a well-ventilated location will ensure that heat does not build up inside
the cabinet.
Do not  place the VR-5000 on top of another heat-generating device, and keep its top
cover free of books, papers, and other objects which might impede...
Start reading Yaesu Musen Yaesu Vr 5000 Communications Reciever Operating Manual

Related Manuals for Yaesu Musen Yaesu Vr 5000 Communications Reciever Operating Manual

All Yaesu Musen manuals