Page 82
DHS-E Description3-1 DHS-E Description System Technolog y Incorporating state-of-the-art digital technology for voice switching and call processing, the DHS-E utilizes Pulse Code Modulation and Time Division Multiplexing (PCM/TDM). The DHS-E family is engineered to allow migration of digital telephones and accessories throughout the entire product line (refer to Digital Key Telephones, in Chapter 2, DHS Description and Installation). ISDN-like, 2B+D technology complements the system architecture...
Page 83
3-2DHS-E Description DHS-E is expandable to meet a variety of applications. Regardless of the configuration, the system has sufficient resources to allow completely non-blocked access to all facilities (intercom and CO lines). An external music source may be connected to each BGM/MOH Jacks via a 1/8 in. phono plug for BGM/MOH listening. All system features are supported by the equipment provided in the DHS-E KSU. The Main Processor Board provides two Dual Tone Multi- Frequency (DTMF) receivers and...
Page 84
DHS-E Description3-3 System Administration The systems default customer data base can be entered and changed, under password control, from any Executive Key Telephone. All Customer information is protected by an internal rechargeable NiCad or NiMh battery. Programmable password protection is allowed for each station, system administrator and external (DISA) callers. An optional PC Programming Software is available to program the DHS-E Systems. This Software allows the user to program OFF/LINE and...
Page 85
3-4DHS-E Description Power Supply The power supply circuitry of the DHS-E incorporates a linear design transformer with a choice of input voltage taps. The transformer primary windings are shipped wired for 117V AC applications. Since the power supply is linear in design the output voltage varies between 21.6V DC and 32V DC depending on load and stability of the input voltage. The output voltage is delivered to the CPU board for distribution and rectified there for logic and control voltages. Two...
Page 86
DHS-E Description3-5 Figure 3-2: Firmware Caution Figure 3-3: 3 x 8 Module Although all existing 3 x 8 boards can be used when upgrading an existing DHS system, some pre-qualification must be performed. This pre-qualification will prevent noise problems on stations that can result from a firmware incompatibility issue. This issue can be corrected by obtaining the correct firmware from Vodavi (refer to Figure 3-2: Firmware Caution for further information). Firmware MFG Name TEC9352 TC5649.1XXXX...
Page 87
3-6DHS-E Technical Specification Tables DHS-E Technical Specification Tables Table 3-2: Digital Hybrid System Capacities Component Description Customer Database memory protection 300 hr on a fully charged battery (the internal Nicad/Nimh battery requires 14 hr, of continuous system operation power be fully charged.) Ports: CO/PBX/Centrex Lines 18 Digital Stations 48 Standard Single Line Telephones 94 (Note: one digital port must be reserved for digital station operation. One digital station port is...
Page 88
DHS-E Technical Specification Tables3-7 Hunt Groups: Members per group 8 Group Types 24 Pilot Hunt Group, All Ring Group or Voice Mail Group Voice Mail Groups: 1 (Selected as VM type from HG.) Members (ports) 24 Integration Method: In-band VM Message Waiting [#] + [96] + station number to turn VM button LED ON. [#] + [✳] + [96] + station number to turn VM button LED OFF. VM Control Codes: Disconnect Digit(s) 8 digits max. Prefix for intercom calls 4 digits max. Prefix for transferred calls 4 digits...
Page 89
3-8DHS-E Technical Specification Tables Save Number Redial 16 digits per station User Saved Number Redial 20 digits per station Callback request per station 1 Camp On by a busy station 1 Stations Camped on to a station 1 Stations Camped on to a busy line 1 Message - Executive Notification: 6 preprogrammed 1 personal per station Message - Executive Preprogrammed 6 preprogrammed 1 personal per station Message Waiting 48 simultaneous Name in Display 1 per station, 7 characters max. Class Of Service (COS) 8...
Page 90
DHS-E Technical Specification Tables3-9 Table 3-3: Electrical Specifications Component Description AC Power source: Dedicated 117V AC (+ 10%), 60Hz single phase Power consumption: 1.5A max. at 120V AC (180 W ) Power Supply fuse: AC input DC output2A 250V 1A 125V Idle Channel Noise: -74 dB Cross Talk Attenuation: 75 dB (at 1kHz) Ringing Sensitivity: 40v RMS 25 Hz Ringer Equivalence Number: 1.2B CO Line Signaling: DTMF amplitude (-5 dB,-7 dB) +- 2 dB, at approx. 2 Vpp Pulse Dialing ratio 60/40 at 10...