DHS-E Description3-1
DHS-E Description
System Technolog y
Incorporating state-of-the-art digital technology for voice switching and call processing, 
the DHS-E  utilizes Pulse Code Modulation and Time Division Multiplexing (PCM/TDM). 
The DHS-E  family is engineered to allow migration of digital telephones and accessories 
throughout the entire product line (refer to Digital Key Telephones, in Chapter 2, DHS 
Description and Installation). ISDN-like, 2B+D technology complements the system 
architecture...

Page 83

3-2DHS-E Description
DHS-E  is expandable to meet a variety of applications. Regardless of the configuration, 
the system has sufficient resources to allow completely non-blocked access to all facilities 
(intercom and CO lines).
An external music source may be connected to each BGM/MOH Jacks via a 1/8 in. phono 
plug for BGM/MOH listening. All system features are supported by the equipment 
provided in the DHS-E  KSU. The Main Processor Board provides two Dual Tone Multi-
Frequency (DTMF) receivers and...

Page 84

DHS-E Description3-3
System Administration
The systems default customer data base can be entered and changed, under password 
control, from any Executive Key Telephone. All Customer information is protected by an 
internal rechargeable NiCad or NiMh battery. Programmable password protection is 
allowed for each station, system administrator and external (DISA) callers. An optional PC 
Programming Software is available to program the DHS-E Systems. This Software allows 
the user to program OFF/LINE and...

Page 85

3-4DHS-E Description
Power Supply
The power supply circuitry of the DHS-E incorporates a linear design transformer with a 
choice of input voltage taps. The transformer primary windings are shipped wired for 
117V AC applications. Since the power supply is linear in design the output voltage varies 
between 21.6V DC and 32V DC depending on load and stability of the input voltage. The 
output voltage is delivered to the CPU board for distribution and rectified there for logic 
and control voltages.
Two...

Page 86

DHS-E Description3-5
Figure 3-2: Firmware Caution
Figure 3-3: 3 x 8 Module
Although all existing 3 x 8 boards can be used when upgrading an existing DHS system, 
some pre-qualification must be performed. This pre-qualification will prevent noise 
problems on stations that can result from a firmware incompatibility issue. This issue can 
be corrected by obtaining the correct firmware from Vodavi (refer to 
Figure 3-2: Firmware 
Caution
 for further information).
Firmware
MFG Name
TEC9352
TC5649.1XXXX...

Page 87

3-6DHS-E Technical Specification Tables
DHS-E Technical Specification Tables
Table 3-2: Digital Hybrid System Capacities
Component Description
Customer Database memory protection 300 hr on a fully charged battery (the internal 
Nicad/Nimh battery requires 14 hr, of continuous 
system operation power be fully charged.)
Ports:
CO/PBX/Centrex Lines 18 
Digital Stations 48
Standard Single Line Telephones 94 
(Note: one digital port must be reserved for 
digital station operation. One digital station port 
is...

Page 88

DHS-E Technical Specification Tables3-7
Hunt Groups:
Members per group 8
Group Types 24
Pilot Hunt Group, All Ring Group or Voice Mail 
Group
Voice Mail Groups: 1 (Selected as VM type from HG.)
Members (ports) 24
Integration Method: In-band
VM Message Waiting [#] + [96] + station number to turn VM button LED 
ON.
[#] + [✳] + [96] + station number to turn VM 
button LED OFF.
VM Control Codes:
Disconnect Digit(s) 8 digits max.
Prefix for intercom calls 4 digits max.
Prefix for transferred calls 4 digits...

Page 89

3-8DHS-E Technical Specification Tables
Save Number Redial 16 digits per station
User Saved Number Redial 20 digits per station
Callback request per station 1
Camp On by a busy station 1
Stations Camped on to a station 1
Stations Camped on to a busy line 1
Message - Executive Notification: 6 preprogrammed
1 personal per station
Message - Executive Preprogrammed 6 preprogrammed
1 personal per station
Message Waiting 48 simultaneous
Name in Display 1 per station, 7 characters max.
Class Of Service (COS) 8...

Page 90

DHS-E Technical Specification Tables3-9
  
Table 3-3: Electrical Specifications
Component Description
AC Power source: Dedicated 117V AC (+
10%), 60Hz single 
phase
Power consumption: 1.5A max.  at 120V AC (180 W )
Power Supply fuse:
AC input
DC output2A 250V
1A 125V
Idle Channel Noise: -74 dB
Cross Talk Attenuation: 75 dB (at 1kHz)
Ringing Sensitivity: 40v RMS 25 Hz
Ringer Equivalence Number: 1.2B
CO Line Signaling: DTMF amplitude (-5 dB,-7 dB) +- 2 dB, at 
approx. 2 Vpp
Pulse Dialing ratio 60/40 at 10...