Page 31
2-8DHS General Description Enhanced Key Telephone The Enhanced Key Telephone is fully equipped for hands-free, speakerphone operation. This key telephone is expanded to 28 buttons. Eight fixed function buttons remain consistent with those of the Basic Key Telephone. Twenty buttons are user-programmable feature buttons equipped and dual color LED with pre-assigned default settings for quick power up operation. These buttons are arranged in five rows and four columns. Beginning at the top left button...
Page 32
DHS General Description2-9 Executive Key Telephone The Executive Key Telephone model has a 2 x 16, 32-character Super Twist LCD display, with three interactive Soft Buttons to enhance system features operation. The Super Twist LCD eliminates the need for contrast adjustment and enhances angled viewing position clarity of displayed data. A visual reference to call progress and call duration, as well as time and date information, is displayed. The display also enables the Executive Key Telephone user...
Page 33
2-10DHS General Description Direct Station Selector (DSS) Console Previously only available on the DHS-E, the Direct Station Selector (DSS) Console is now also available on the DHS. One DSS Console may be assigned to a station. Each DSS Console uses one Digital Station Port. Up to 12 DSS Consoles can be installed on a system. The DSS Console buttons are programmed by the Station User using the FEAT + # + 5 command, then pressing the button on the DSS to be programmed. All system feature codes may...
Page 34
DHS General Description2-11 2-Port Analog Adapter A 2-Port Analog Adapter is optionally available which will support most auxiliary equipment within a business environment such as fax machines, answering devices and Single Line Telephones (SLT). Each adapter requires an unused digital station port and will yield two analog device interfaces. The 2-Port Analog Adapter is a wall mount apparatus that is powered from the KSU. The adapter receives both voice channels and data control from the KSU, over...
Page 35
2-12DHS General Description Two-Port Analog Expander A 2-Port Analog Expander module is optionally available and is designed to be installed inside the 2-Port Analog Adapter housing. The 2-Port Analog Expander provides the same interface capabilities of the 2-Port Analog Adapter and is in fact comprised of the same circuit board used inside the 2-Port Analog Adapter. Loop disconnect and message waiting lamps are not supported by the analog adapter. Figure 2-11: 2-Port Analog Expander The 2-Port...
Page 36
DHS Technical Specification Tables2-13 DHS Technical Specification Tables Table 2-2: Digital Hybrid System Capacities Component Description System Programming Memory Protection 300 Hours on a fully-charged battery (internal Nicad/Nimh battery requires 14 continuous- powered hours of system operation to become fully charged.) Ports: CO/PBX/Centrex Lines 12 (Note: 16 stations max. with this configuration.) Digital Stations 24 (Note: 9 CO lines max. with this configuration.) Standard SLTs 46 (Note: one...
Page 37
2-14DHS Technical Specification Tables System Attendants 1 + 1 Alternate position for overflow call handling. Hunt Groups 8 Members per Group 24 Group Types Pilot Hunt Group (HG), All Ring Group, or Voice Mail ( VM) Group Voice Mail Groups: 1 (Selected as VM type from HG) Members (ports) 24 Integration Method: In-band VM Message Waiting [#] + [96] + station number to turn VM button LED on. [#] + [✳] + [96] + station number to turn VM button LED off. VM Control codes: Disconnect Digit(s) 8 digits...
Page 38
DHS Technical Specification Tables2-15 Callback Request Per Station 1 Camp On By A Busy Station 1 Stations Camped On To Station 1 Stations Camped On To Busy Line 1 Message - Executive Notification 6 Preprogrammed; 1 Personal per station Message - Executive Preprogrammed 6 Preprogrammed; 1 Personal per station Message Waiting 32 Simultaneous Name in Display 1 Per station, 7 characters max. Class Of Service (COS) 8 (0-7) per Day, 8 (0-7) per Night Toll Restriction To/From Tables 100 Entries, 10 digits per...
Page 39
2-16DHS Technical Specification Tables Table 2-3: Electrical Specifications Component Description AC Power Source Dedicated 117/230V AC + 15% (47-63 Hz single phase) Power consumption 1.5A max. at 120V AC (180 W ) Power Supply fuse: AC input DC output2A 250V 1A 125V Idle Channel Noise -74 dB Cross Talk Attenuation 75 dB (at 1 kHz) Ringing Sensitivity 40V RMS 25 Hz Ringer Equivalence Number 1.0B CO Line Signaling DTMF amplitude (-5, -7 dB) +- 2 dB, at approx. 2 Vpp Pulse Dialing ratio 60/40 at 10 Pps...
Page 40
DHS Technical Specification Tables2-17 Table 2-4: Environmental Specifications Requirements In Operation In Storage Temperature KSU 32 to 104o F 0 to 40o C-40 to 185 o F -40 to 85o C Recommended Operating Te m p e ra t u re70 to 78 o F Temperature Station Instruments 32 to 113o F 0 to 45o C-40 to 185 o F -40 to 85o C Relative Humidity (non-condensing)5 to 90% 5 to 90% Heat Dissipation (BTU) 300 Altitude Up to 10,000 ft. (3,048 m)Up to 40,000 ft. (12,192 m)