Page 71
— 64 — 4. Unlock the lamp cover. 5. Pull up and remove the cover. 6. Use a screwdriver to remove the screws from the lamp module. 7. Pull out the lamp module.
Page 72
– 65 – 8. Reverse steps 1 to 7 to install the new lamp module. While installing, align the lamp module with the connector and ensure it is level to avoid damage. Note: The lamp module must sit securely in place and the lamp connector must be connected properly before tightening the screws. 9. Turn on the projector and reset the lamp after the lamp module is replaced. Lamp Reset: Press Menu > Select SYSTEM SETUP >> Advanced > Select Lamp Settings > Select Reset Lamp Timer > Press...
Page 73
— 66 — Cleaning the Projector Cleaning the projector to remove dust and grime will help ensure trouble-free operation. Warning: 1. Be sure to turn off and unplug the projector at least 30 minutes before cleaning. Failure to do so could result in a severe burn. 2. Use only a dampened cloth when cleaning. Do not allow water to enter the ventilation openings on the projector. 3. If a little water gets into the projector interior while cleaning, leave unplugged in a well-ventilated room for...
Page 74
– 67 – Cleaning the Air Filter Refer to the following to clean the air filter. 1. Open the latch to open the filter door. 2. Remove the filter.
Page 75
— 68 — 3. Use a vacuum cleaner to vacuum the dust inside. Note: 1. Use the soft brush attachment when you vacuum the filter to avoid damage it. 2. Do not wash the filter with water. Doing so can result in filter clogging. 4. Put the filter back.
Page 76
– 69 – 5. Close the filter door and lock the latch. 6. Turn on the projector and reset the lamp after the lamp module is replaced. Lamp Reset: Press MENU > Select SYSTEM SETUP >> Advanced and select Air Filter Timer Reset. Press ENTER to reset timer. Important: The Filter LED lights when the filter service time is on (1000 hours). If the filter is broken, please use a new one.
Page 77
— 70 — Using the Physical Lock Using the Kensington® Security Slot If you are concerned about security, attach the projector to a permanent object with the Kensington slot and a security cable. Note: Contact your vendor for details on purchasing a suitable Kensington security cable. The security lock corresponds to Kensington’s MicroSaver Security System. If you have any com- ment, contact: Kensington, 2853 Campus Drive, San Mateo, CA 94403, U.S.A. Tel: 800-535-4242, http://www.Kensington.com....
Page 78
– 71 – TROUBLESHOOTING Common Problems and Solutions These guidelines provide tips to deal with problems you may encounter while using the projector. If the problem remains unsolved, contact your dealer for assistance. Often after time spent troubleshooting, the problem is traced to something as simple as a loose connection. Check the following before proceeding to the problem-specific solutions. Use some other electrical device to confirm that the electrical outlet is working. Ensure the...
Page 79
— 72 — LED Error Messages ERROR CODE MESSAGES POWER LED LAMP LED TEMP LED FILTER LED Lamp Ready ON Start Flashing Cooling Flashing Over Temperature ON Thermal Break Sensor error 4 blinks Lamp Re-Strike 6 times Failed 5 blinks Lamp Temperature shut down (Ballast Temp) 5 blinks 1 blinks Lamp Short circuit in output detected (Ballast circuit short) 5 blinks 2 blinks Lamp End of lamp life detected 5 blinks 3 blinks Lamp did not ignite 5 blinks 4 blinks Lamp...
Page 80
– 73 – Image Problems Problem: No image appears on the screen 1. Verify the settings on your notebook or desktop PC. 2. Turn off all equipment and power up again in the correct order. Problem: The image is blurred 1. Adjust the Focus on the projector. 2. Press the Auto button on the remote control or projector. 3. Ensure the projector-to-screen distance is within the 10-meter (33-feet) specified range. 4. Check that the projector lens is clean. Problem: The image is wider at the top or...