ViewSonic Vt3200-l Manual
Here you can view all the pages of manual ViewSonic Vt3200-l Manual. The ViewSonic manuals for Display are available online for free. You can easily download all the documents as PDF.
Page 41
Other Information 32 Problem Possible Solution Remote control unit does not operate• Make sure the batteries are inserted correctly. • Batteries could be weak or dead. Replace with new batteries. • H control sensor. • The path of the remote control beam may be blocked. Make sure the path is clear and that the remote control is aimed at the remote control sensor on the TV. • Press on the remote control to see if you can turn on the TV. • Press MENU on the remote control to see if there is an OSD...
Page 42
Other Information 33 6SHFL¿FDWLRQV Model VT3200-L VT4200-L LCD (LED Backlight)Screen Size 32-inch Full HD 60Hz 42-inch Full HD 60Hz Aspect Ratio 16:9 16:9 Television SystemATSC / 64 & 256 QAM / NTSC-MATSC / 64 & 256 QAM / NTSC-M Program Coverage 9+)a8+)aDTV : 02-69 &$79a&$79a Input signalRGB RGB analog (0.7/1.0 Vp-p, 75 ohms) Separate Sync, fh: 31.5-67.5 kHz, fv:59.94-60 Hz RF TV system Antenna / NTSC+ATSC, TV cable system /...
Page 43
Other Information 34 RS232 Protocol 1. Introduction This document describes the hardware interface spec and software protocols of RS232 interface communication between Viewsonic Commercial Display and PC or other control unit with RS232 protocol. The protocol divide into three sections: • Set-Function • Get-Function • Remote control pass-through mode * In below document, “PC” will represents all the control units that can sent or receive the RS232 protocol command. 2. Description...
Page 44
Other Information 35 3. Protocol 3.1 Set-Function Listing 7KH3&FDQFRQWUROWKH790RQLWRUIRUVSHFL
Page 45
Other Information 36 Reply (Hex Format) NameLength ID Command Ty p eCR Hex 0x340x30 0x320x2B0x0D Example2: Set Brightness as 176 for TV-02 and this command is NOT valid. Send (Hex Format) NameLength ID Command Ty p eCommand Value1 Value2 Value3 CR Hex 0x380x30 0x320x730x240x310x370x360x0D Reply (Hex Format) NameLength ID Command Ty p eCR Hex 0x340x30 0x320x2D0x0D Set-function table Set FunctionLength ID Command Type (ASCII)Command Value Range (Three ASCII bytes)Comments Code (ASCII) Code (Hex)...
Page 46
Other Information 37 OSD language8 s 2 32 000: English 001: French 002: SpanishExtend the value for more supported languages Power lock 8 s 4 34 000 : Unlock 001 : Lock Volume 8 s 5 35a Mute 8 s 6 36 000: OFF 001: ON (mute) Button lock 8 s 8 38 000: Unlock 001: Lock TV channel (DTV)8 s < 3C For -0: a $a) a For -k: 1 st and 2nd char are same as -0 3 th char is CHAR[ ASC(3th digi)+ k x 10 ]It’s channel OSD number but not frequency number. TV channel (ATV)8s= 3Da Menu...
Page 47
Other Information 38 [NOTE] 1. Behavior at lock modes Lock Mode Behavior Button Lock 1. Lock all buttons of front panel and RCU, except for “Power” 2. All the SET functions should be workable via RS32, even the ones with according hot key in RCU like Mute,…etc. MENU Lock 1. Lock “MENU’ key of front panel and RCU 2. The Factory and Hospitality modes should not be blocked for the model using MENU-combined key to enter these two modes. Alternative approach will be indicated separately if any limitation by...
Page 48
Other Information 39 Get-Function format: Send: (Command Type= “g”) NameLength ID Command Ty p eCommand Value1 Value2 Value3 CR Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order1a4 5 6789 Reply: (Command Type= “r” or “-”) If the Command is valid, Command Type = “r” NameLength ID Command Ty p eCommand Value1 Value2 Value3 CR Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order1a4 5 6789 If the Command is Not valid, Command Type= “-” NameLength...
Page 49
Other Information 40 Reply (Hex Format) Name Length ID Command Ty p eCR Hex 0x340x30 0x350x2D0x0D Get-function table Get FunctionLength ID Command Ty p eCommand Response Range (Three ASCII bytes)Comments Code (ASCII) Code (Hex) Get-Contrast 8 g a 61a Get-Brightness 8 g b 62a Get-Sharpness 8 g c 63a Get-Color 8 g d 64a Get-Tint 8 g e 65a Get-Volume 8 g f 66a Get-Mute 8 g g 67 000: Off 001: On (muted) Get-Input select 8 g j 6AaSee Set-function...
Page 50
Other Information 41 IR Pass Through-Function format Reply: (Command Type= “p”) NameLength ID Command Ty p eRCU Code1 (MSB)RCU Code2 (LSB)CR Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order1a45 67 Example1: Remote Control pass-through when “VOL+” key is pressed for TV-05 Reply (Hex Format) NameLength ID Command Ty p eRCU Code1 (MSB)RCU Code2 (LSB)CR Hex 0x360x30 0x350x700x310x300x0D Key Code (HEX) 101 202 303 404 505 606 707 808 909 00A -0B RECALL (LAST) 0C 0D 0E ASPECT (ZOOM) 0F...