Page 11
10 Control Explanation Information displays the timing mode (video signal input) coming from the graphics card in the computer, the LCD model number, the serial number, and the ViewSonic® website URL. See your graphics card’s user guide for instructions on changing the resolution and refresh rate (vertical frequency). NOTE: VESA 1440 x 900 @ 60Hz (recommended) means that the resolution is 1440 x 900 and the refresh rate is 60 Hertz. Manual Image Adjust displays the...
Page 12
11 Control Explanation Setup Menu displays the menu shown below: Language Select allows the user to choose the language used in the menus and control screens. Resolution Notice advises the optimal resolution to use. OSD Position allows the user to move the OSD menus and control screens. OSD Timeout sets the length of time the OSD screen is displayed. For example, with a “15 second” setting, if a control is not pushed within 15 seconds, the display screen...
Page 14
15 5. Adjustment Procedure 1. All Modes Reset You should do “All Model Reset” (Refer to Chap 3. Hot Keys for Function Controls) first. This action will allow you to erase all end-user’s settings and restore the factory defaults. 2. Auto Image Adjust The Auto Adjust is aimed to offer a best screen quality by built-in ASIC. For optimum screen quality, the user has to adjust each function manually. A.Turn the computer and LCD monitor on. B. Press the ‘Auto’ button on monitor keypad to Auto...
Page 15
16 7. 25 Gray Test Signal: 1280*1024@60Hz Test Pattern: Full Screen 25% White (Gray) Inspection Item: Particle, Line Defect & Mura 8. 50 Gray Test Signal: 1280*1024@60Hz Test Pattern: Full Screen 50% White (Gray) Inspection Item: Bright Dot, Particle, Line Defect & Mura 9. White Box Test Signal: 1280*1024@60Hz Test Pattern: Window standard pattern Inspection Item: Particle, Line Defect, Power, Image Remain & Mura 10. Black Box Test Signal: 1280*1024@60Hz Test...
Page 16
17 12. Green Test Signal: 1280*1024@60Hz Test Pattern: Full Screen Green Inspection Item: Bright Dot, Partial & Line Defect 13. Blue Test Signal: 1280*1024@60Hz Test Pattern: Full Screen Green Inspection Item: Bright Dot, Partial & Line Defect 14. Gray_Scale_0-100_V64 Test Signal: 1280*1024@60Hz Test Pattern: Vertical 64 (256) Gray Scale (Right → Left,From 0 to 100% White) Inspection Item: Line Defect & Function Defect 15. Function Test Display pattern Item...
Page 18
19 Factory Defaults Item Defaults Item Defaults Contrast 70% Input Priority N/A Brightness 100% Resolution Notice On Color Temperature 6500K Volume N/A Sharpness 100% Balance N/A OSD H. Position 50% Treble N/A OSD V. Position 50% Bass N/A OSD Time Out 15 720x400 / 640x400 720x400 OSD Background On DCR ON ECO Mode Standard Aspect Ratio Full screen RTD2120 ISP user flow Software : RTD ISP Ver3.0 Hardware : Print to D-Sub and DVI-D Converter Figure 8 Figure...
Page 19
20 Step 1. Update BIOS Flow: Execute ISP.exe Step2. Click【64K】, Select the first file name xxxxxxxxxx_1.hex and Click【64~96】, Select the second file name xxxxxxxx_2.hex Step 3. Select【Both】and 【Auto】.