ViewSonic Va1916w2 Service Manual
Have a look at the manual ViewSonic Va1916w2 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 617 ViewSonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
10 Control Explanation Information displays the timing mode (video signal input) coming from the graphics card in the computer, the LCD model number, the serial number, and the ViewSonic® website URL. See your graphics card’s user guide for instructions on changing the resolution and refresh rate (vertical frequency). NOTE: VESA 1440 x 900 @ 60Hz (recommended) means that the resolution is 1440 x 900 and the refresh rate is 60 Hertz. Manual Image Adjust displays the Manual Image Adjust menu. H./V. Position (Horizontal/Vertical Position) moves the screen image left or right and up or down. H. Size (Horizontal Size) adjusts the width of the screen image. Fine Tune sharpens the focus by aligning text and/or graphics with pixel boundaries. NOTE: Try Auto Image Adjust first. Sharpness adjusts the clarity and focus of the screen image. Aspect ratio Selects the image size for 4:3 and full screen. ECO Mode provides the lower power consumption by reducing the brightness. Standard: The default brightness setting Optimize: Decreases the brightness by 25 % Conserve: Decreases the brightness by 50 % NOTE: When the ECO Mode is set to Optimize or Conserve, the Brightness, Contrast, and Dynamic Contrast cannot be adjusted.
11 Control Explanation Setup Menu displays the menu shown below: Language Select allows the user to choose the language used in the menus and control screens. Resolution Notice advises the optimal resolution to use. OSD Position allows the user to move the OSD menus and control screens. OSD Timeout sets the length of time the OSD screen is displayed. For example, with a “15 second” setting, if a control is not pushed within 15 seconds, the display screen disappears. OSD Background allows the user to turn the OSD background On or Off. Memory Recall returns the adjustments back to factory settings if the display is operating in a factory Preset Timing Mode listed in the Specifications of this manual. Exception: This control does not affect changes made with the User Color control, Language Select or Power Lock setting.
15 5. Adjustment Procedure 1. All Modes Reset You should do “All Model Reset” (Refer to Chap 3. Hot Keys for Function Controls) first. This action will allow you to erase all end-user’s settings and restore the factory defaults. 2. Auto Image Adjust The Auto Adjust is aimed to offer a best screen quality by built-in ASIC. For optimum screen quality, the user has to adjust each function manually. A.Turn the computer and LCD monitor on. B. Press the ‘Auto’ button on monitor keypad to Auto Adjust. C. The LCD monitor will start the Auto Adjust process automatically and run for 10 consecutive seconds, during which time you will notice the image change. 3. Firmware Test Patten: Burn in Model (Refer to Chap3. Hot Keys for Function Control) -Make sure the F/W is the latest version. 4. DCC Test Patten: EDID program -Make sure it can pass test program. 5. Window Shut Down Test Signal: 1280*1024@60Hz Test Pattern: Checkered Pattern Every One Pixel (50%Green & 50%Blue) Inspection Item: Flicker, Mura 6. Window BG Test Signal: 1280*1024@60Hz Test Pattern: Window standard pattern Inspection Item: Line Defect, Function Defect & Mura
16 7. 25 Gray Test Signal: 1280*1024@60Hz Test Pattern: Full Screen 25% White (Gray) Inspection Item: Particle, Line Defect & Mura 8. 50 Gray Test Signal: 1280*1024@60Hz Test Pattern: Full Screen 50% White (Gray) Inspection Item: Bright Dot, Particle, Line Defect & Mura 9. White Box Test Signal: 1280*1024@60Hz Test Pattern: Window standard pattern Inspection Item: Particle, Line Defect, Power, Image Remain & Mura 10. Black Box Test Signal: 1280*1024@60Hz Test Pattern: Window standard pattern Inspection Item: Bright Dot, Line Defect & Power 11. RED Test Signal: 1280*1024@60Hz Test Pattern: Full Screen Red Inspection Item: Bright Dot, Partial & Line Defect
17 12. Green Test Signal: 1280*1024@60Hz Test Pattern: Full Screen Green Inspection Item: Bright Dot, Partial & Line Defect 13. Blue Test Signal: 1280*1024@60Hz Test Pattern: Full Screen Green Inspection Item: Bright Dot, Partial & Line Defect 14. Gray_Scale_0-100_V64 Test Signal: 1280*1024@60Hz Test Pattern: Vertical 64 (256) Gray Scale (Right → Left,From 0 to 100% White) Inspection Item: Line Defect & Function Defect 15. Function Test Display pattern Item Pattern Description Remark 1 Gray_Scale_0-100_V Vertical 64 (256) Gray Scale (右→左,From 0 to 100% White) Figure 1 2 Gray_Scale_0-100_H Horizontal 64 (256) Gray Scale (上→下,From 0 to 100% White) Figure 2 3 Black Full Screen Black Figure 3 4 Red Full Screen 50% Red Figure 4 5 Green Full Screen 50% Green Figure 5 6 Blue Full Screen 50% Blue Figure6 7 White Full Screen White Figure7 8 Black_Tile Black Tile Under White Background Figure 8
18 Figure 1 Figure 2 Figure 5 Figure 4 Figure 6 Figure 3 Figure 5
19 Factory Defaults Item Defaults Item Defaults Contrast 70% Input Priority N/A Brightness 100% Resolution Notice On Color Temperature 6500K Volume N/A Sharpness 100% Balance N/A OSD H. Position 50% Treble N/A OSD V. Position 50% Bass N/A OSD Time Out 15 720x400 / 640x400 720x400 OSD Background On DCR ON ECO Mode Standard Aspect Ratio Full screen RTD2120 ISP user flow Software : RTD ISP Ver3.0 Hardware : Print to D-Sub and DVI-D Converter Figure 8 Figure 7
20 Step 1. Update BIOS Flow: Execute ISP.exe Step2. Click【64K】, Select the first file name xxxxxxxxxx_1.hex and Click【64~96】, Select the second file name xxxxxxxx_2.hex Step 3. Select【Both】and 【Auto】.