Page 31
31 What to do when these messages are displayed Message Cause (Details) No device is connected to the DVI terminal. The terminal is connected but there is no signal output. ➝ Input the video signals. When lamp time reaches 1000 hours ➝ A message indicating “1000 h” will be displayed on the screen. • Press the [EXIT ] button to clear the display. At the moment when the accumulated lamp time reaches 1900 hours, a “Lamp replacement” message will be displayed. In addition, when the accumulated lamp...
Page 32
32 Warning Indication About warning indicators If an abnormality occurs in this unit during projection, the warning mode will be triggered and the type of abnormality will be indicated by a combination of indicators displayed on the control panel. This unit will then automatically stop projection and run the cooling fan for about 90 seconds. No. Indicator Warning [LAMP] [TEMP] [STAND BY] [OPERATE] 1 Blinking Blinking Lamp does not light up and unit is unable to project 2 Blinking Blinking...
Page 33
33 Troubleshooting Before sending the unit to your Vidikron dealer for repair, check the following points. Symptom Probable Cause Corrective Action Reference Page Power is not supplied. • Is the power cord disconnected? • Insert the power cord (plug) fi rmly. 4 – 6, 20 • Is the lamp cover properly shut? • Contact your Vidikron dealer for service.29 • Is the fi lter cover properly shut? • Contact your Vidikron dealer for service.30 • Has the lamp life expired? (Has the lamp usage time reached 2000...
Page 34
34 Terminal Description Pin Arrangement Pin No. Signal Name Pin No. Signal Name 1 N/C 6 N/C 2 RD 7 N/C 3 TD 8 N/C 4 N/C 9 N/C 5 GND Pin No. Signal Name Pin No. Signal Name 1 TMDS data 2- 13 N/C 2 TMDS data 2+ 14 TMDS +5 V power supply 3 TMDS data 2/4 shield 15 Earth (+5 V ) 4 N/C 16 Hot plug detection 5 N/C 17 TMDS data 0- 6 DDC clock 18 TMDS data 0+ 7 DDC data 19 TMDS data 0/5 shield 8 N/C 20 N/C 9 TMDS data 1- 21 N/C 10 TMDS data 1+ 22 TMDS clock shield 11 TMDS data 1/3 shield 23 TMDS clock + 12 N/C 24...
Page 35
35 RS-232C External Control Control of this unit via an automation control system is possible by connecting it to this unit with a RS-232C cross cable (D-sub 9 pins). The commands to control this unit and the response data format against the received commands are explained here. For details, please consult your authorized dealer. 1. Communication Specifi cations Communication specifi cation for this unit are as follows: Baud Rate 9600/19200 bps Data Length 8 bit Parity None Stop Bit 1 bit Flow Control...
Page 36
36 2-3. Parameters used for the data format The following 3 types of parameters are used for command and response data: 1 Numeric value 2 ON/OFF 3 Special parameters Each parameter is as follows: 1 Numeric value A 2-byte hexadecimal value (sign included) is represented by a set of 4-digit (4-byte) characters. Assignable range: 8000H to 7FFFH 2 ON/OFF Shows the status (ON or OFF) of the unit, such as POWER and HIDE. Character Hex Meaning 0 30 OFF 131ON 3 Special...
Page 37
37 Specifi cations Projection Type:D-ILA, 3-chip, 0.82 in. diagonal Native Resolution:1920 x 1080 (16:9) Aspect Ratio: 4:3, Letterbox,16:9 Anamorphic DTV Compatibility:480p, 720p, 1080i, 1080p Picture Size (16:9 screen):Recommended Width: 72 – 96 in. Maximum Width: 240 in. Light Output: CSMS* Specifi cations: Home Theater Calibration: 491 ANSI Lumens; 18.1 Foot-Lamberts (fL); 1050 ANSI Lumens Contrast Ratio:2100:1 ANSI Lamp:250 W UHP Estimated Lamp Life:2000 Hours @ 6500 Kelvin Inputs:(1) DVI w/HDCP,...
Page 40