Operation Vidikron Vision Model 120 Owner’s Operating Manual 59 PREL IMINARY CalibrationUse the Calibration menu to perform advanced picture quality adjustments. This menu should be used by ISF-certified technicians only. To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the ISF Presets menu (see page 58) or use the corresponding buttons on the remote control. ISF Night - Display Color: Use the Display Color settings to adjust the color balance at the projector...
Page 72
Operation 60 Vidikron Vision Model 120 Owner’s Operating Manual PREL IMINARY ISF Night - Input Color: The Input Color controls are similar to those in the Display Color menu (see above), but adjust the color balance of the incoming signal. These settings are also saved independently for each input. • Gain/Offset: Refer to ISF Night - Display Color, above. • Chroma Delay: use the Chroma Delay control to correct a mis-aligned image from a Composite, S-Video or Component video source. Chroma delay in...
Page 73
Operation Vidikron Vision Model 120 Owner’s Operating Manual 61 PREL IMINARY ServiceUse the Service menu to access advanced projector configuration settings. This menu should be used by ISF-certified technicians only. Test Video: Select Test Video from the Service Menu to access the internal test patterns on the Vision 120. Four patterns are available: Horizontal Ramp, Vertical Ramp, Color Bars 1 (solid bars) and Color Bars 2 (SMPTE “checkerboard” pattern). Press MENU to exit test pattern mode....
Page 74
Operation 62 Vidikron Vision Model 120 Owner’s Operating Manual PREL IMINARY Triggers: Select Triggers from the Service menu to configure the 12-volt trigger outputs. You can assign one or more trigger outputs to each aspect ratio. Those triggers are then activated by selecting that aspect ratio. If your projector is equipped with the Vidikron CineWide with AutoScope system, assign at least one trigger output (the same one to which the lens motor is connected) to the Cinema and IntelliWide 2.35...
Page 75
Vidikron Vision Model 120 Owner’s Operating Manual 63 PREL IMINARY 5.1 Lamp Replacement The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs. When you replace a lamp, you should replace the filters as well. For lamp or filter replacement, please contact your nearest Vidikron authorized service center or Vidikron dealer. Do not attempt to replace the lamp yourself! 1. Turn off the projector and unplug the...
Page 76
Maintenance and Troubleshooting 64 Vidikron Vision Model 120 Owner’s Operating Manual PREL IMINARY 6. Install the new lamp module. 7. Replace the lamp cover and re-tighten all screws. 5.2 Filter Replacement Whenever you replace the lamp – or more often if the projector is installed in an extremely dusty environment – you should also replace the filter located at the right side of the projector. 1. Loosen the two screws holding the filter access panel in place. Then, remove the panel. 2. Pull the...
Page 77
Maintenance and Troubleshooting Vidikron Vision Model 120 Owner’s Operating Manual 65 PREL IMINARY 5.3 Troubleshooting Tips Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the Vision 120. If the suggested solutions fail to resolve the problem or if you encounter an issue not described here, please contact Vidikron Technical Support. Table 5-1. Troubleshooting Chart SymptomPossible Cause(s)Solution The projector does not turn on after initial...
Page 78
Maintenance and Troubleshooting 66 Vidikron Vision Model 120 Owner’s Operating Manual PREL IMINARY Notes:
Page 79
Vidikron Vision Model 120 Owner’s Operating Manual 67 PREL IMINARY 6.1 RS-232 Connection and Port Configuration To interface the VHD Controller with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-16. Use a null-modem cable. If you are using a PC to communicate with the VHD Controller: 1. Start a terminal session on your PC using a terminal-emulation program, such as HyperTerminal. 2. Configure the...
Page 80
Serial Communications 68 Vidikron Vision Model 120 Owner’s Operating Manual PREL IMINARY Table 6-1 lists the serial commands supported by the VHD Controller and the responses it sends back to the control system or PC. Table 6-1. Serial Commands and Responses CommandDescriptionResponse offTurns projector offPowering Down onTurns projector onPowering Up Gennum Init Complete revDisplay system firmware version information: > rev * Vidikron Gennum Scaler Board * * Rev 0.28 (T01) 05 Jan 2007 * File Name:...