Page 101
101 Searching and Storing Custom Search Custom Search lets you program and search 10 custom search ranges. You can search any of these ranges simultaneously and select each custom search range you set. During custom search, the scanner searches starting with the lowest frequency in the search range you select to the highest frequency in the range. Notes: • Search ranges are preset. See “Editing a Custom Search Range” on Page 102 to change the range. • You cannot turn off all custom search...
Page 102
102 Editing a Custom Search Range You can edit up to 10 custom search ranges. The names of the custom search ranges appear on the display. The default custom search range names appear as Custom 1, Custom 2, and so on. J 4 Search for ... J L 4 Edit Custom L Select your setting, then press the scroll control. Edit Name - lets you edit the custom search range’s name Edit Srch Limit - lets you view and select the frequency ranges to search. The scanner prompts you to enter the upper and lower...
Page 103
103 Searching and Storing Notes: • You can also lock and unlock a search range by pressing , selecting the search range then pressing + L/O. • If you select 0, the scanner then searches the entire range one time. • The default setting is 2 seconds for each search range. • The scanner moves to the next system or search range after the hold time expires, any current transmission ends, and the channel delay time expires. Editing a Service Search You can change the way service search...
Page 104
104Notes: • Turn on this setting if you are near other strong signal sources. Attenuation sometimes helps to reduce interference and desensitization that strong signals create. • Even if ATT appears, attenuation might not work if the bar antenna is turned on and the tuned fre- quency is from 0.1 to 1.7 MHz. •Search with Scan - sets whether the scan- ner includes the service search during scan- ning. If unlocked, the scanner first scans all selected systems, then searches the selected service...
Page 105
105 Searching and Storing Selecting a System To store frequencies or talk group ID’s you find during Auto Store, you must first select a system where the frequencies or talk group ID’s will be stored. J 4 Search for ... J L 4 Search and Store L 4 Select the system where you want to store the fre- quencies or talk group IDs J L If no systems are programmed, No System Stored appears. If you have already stored too many systems, Over Limit appears. Storing a Conventional System You can store...
Page 106
106 Storing a Trunked System You can store talk group ID’s into the system you selected in “Selecting a System”. Otherwise, the scanner stores talk group ID’s in a new group it creates. Note: Trunked system search and store does not work if an EDACS SCAT system is selected, a system with no frequency is selected, the selected system is locked out or the quick key to which the system belongs is turned off, and the group you selected to store found talk group ID’s contains more talk group ID’s...
Page 107
107 Using the Close Call Feature Using the Close Call FeatureYour scanners Close CallTM feature lets you set the scanner so it detects, displays the frequency of, and lets you hear a nearby strong radio transmission. You can set the scanner so the Close Call feature works in the background while you are scanning other frequencies, turn off normal scanning while the Close Call feature is working, or turn off the Close Call feature and use the scanner normally. You can set the scanner so it alerts...
Page 108
108 Setting Close Call Options J 4 Close Call J L Select your setting, then press the scroll control. Then turn the scroll control to select an option. •Close Call Only: Lets you set the scanner only for Close Call searching. The scanner does not scan frequencies or channels when this option is turned on. To select this option, press E. •CC Auto Store: Lets you select whether the scanner automatically stores Close Call hits into channels. If you turn this option on, the scanner starts Close...
Page 109
109 Using the Close Call Feature hit. The scanner displays CC Found! Press Any Key. When you press a key, the frequency appears. Turn the scroll control to display an option, then press the scroll control. •Set CC Alert: Lets you select how the scanner alerts you when it receives a Close Call signal. You can select any of the following options. Select Mode • Beep (the scanner beeps when it receives a Close Call signal) • Light (the backlight turns on when it receives a Close Call signal) •...
Page 110
11 0•Set CC Bands: Lets you select the Close Call band settings. You can turn the following bands on or off. VHF Low (25.000 - 107.900 MHz) Air Band (108.000 - 136.975 MHz) VHF High (137.000 - 317.950 MHz) UHF1 (318.000 - 511.9875 MHz) UHF2 (512.000 - 763.950 MHz) 800MHz+ (764.0000 - 823.9875 MHz, 849.0125 - 868.9875 MHz, 894.0125 - 1300.0000 MHz) Use the scroll control to select a band, press the scroll control, then use the scroll control to select On or Off and...