Page 51
47 PL1 (plan 1): This plan is the most common. Use Plan 1 if the last three digits of ALL the frequencies in use end in one of the following three digits: 125, 375, 625, or 875 (example: 856.1125, 860.7375, 859.6625, 855.8875). PL2 (plan 2): If the last three digits of frequencies are less than 860.000 and end in one of the following three digits (125, 375, 625, or 875) and if ANY other frequencies end in (000, 250, 500, or 750) use Plan 2. PL3 (plan 3): If the last three digits of ALL the frequencies in...
Page 52
Remote Interface You can communicate and program your BCT8 in numerous ways with peripheral devices using a Remote Interface Cable port. This radio offers the following modes: ❖PC Control mode Program and control your scanner from a PC using Uniden’s BCT8 Scanner Software. ❖Clone mode Clone all the frequencies, trunking talkgroups, and fleet maps programmed into your scanner to another BCT8 scanner or another BCT8. PC Control Mode To connect Scanner to PC: Plug the scanner end of the RS232C straight...
Page 53
49 Start Remote Mode and Change Transfer Speed: 1. Press and hold RMTfor 2 seconds to activate the Remote mode. 2. Select the transfer speed except for , then press Eand the scanner will start Remote mode. A unique feature of the BCT8 is that all the front panel keys on the radio remain operational in Remote mode. For information on purchasing BCT8 Scanner software to program and control your BCT8, you can contact the following: Uniden Parts Department (800) 554-3988 (Hours are from 8:00 a.m. to...
Page 54
50 To connect the Scanner to Scanner: Plug the male end of the RS232C straight interface cable into the remote port on the rear of one of the two scanners. Then connect the DB-9 to DB-9 null modem adapter to the cable. Plug the other end of the null modem adapter into the other scanner (DB9 Gender Changers are also available at your local electronics store.). You can clone all of the programming of one BCT8 into another, including frequencies, talkgroup IDs, delay settings, etc. After connecting the two...
Page 55
51 5. The data transfer begins from the First Unit to the Clone Unit. During the data transfer, both scanners show the following displays. When the data transfer is complete, displays. If the data transfer is not successful, the following error message will appear. Note:•To clear , press (decimal key). Note•Once you have completed the cloning of the scanners, reset the scanners by turning the scanners OFF and then ON again. This is particularly important to know if you wish to clone another scanner...
Page 56
Care and Maintenance General Use •Turn the scanner OFF before disconnecting the power. •Always write down the programmed frequencies in the event of memory loss. •If memory is lost, simply reprogram each channel. The display shows 000.0000 in all channels when there has been a memory loss. Location •Do not use the scanner in high-moisture environments such as the kitchen or bathroom. •Avoid placing the unit in direct sunlight or near heating elements or vents. •If the scanner receives strong...
Page 57
53 Troubleshooting If your BCT8 is not performing properly, try the following steps. Problem Suggestion 1. Make sure you are scanning in Highway Mode. 2. Check antenna connections. 3. Conditions to activate the alarm are variable and depend upon the timing of the dispatcher transmissions and proximity of patrol car to your vehicle. Also, terrain and other factors may be involved. 4. Officer has the ability to turn off the mobile extender when off-duty, or when going to court, etc., but will normally...
Page 58
If you experience difficulty while in TrunkTracker mode, try the following steps. If you still cannot get satisfactory results while using your scanner or if you want additional information, please call or write the Uniden Parts and Service Division. The address and phone number is listed in the warranty at the end of this manual. If you would like immediate assistance, please call Customer Service at (800)297-1023. If you have internet access, you can visit scanner.uniden.comfor additional information....
Page 59
55 Specifications Certified in accordance with FCC Rules and Regulations Part 15, Subpart C, as of date of manufacture. Channel: 250 Banks: 5 (50 channels each) Service Bands: 9 preprogrammed search bands (including the NOAA and Canada Weather Service band) Frequency Range: 25.0-28.0 MHz Petroleum Prod., CB Class D channels, Business and Forest Products 28.0-30.0 MHz 10 Meter Amateur Band 30.0-50.0 MHz VHF Low Band 50.0-54.0 MHz 6 Meter Amateur Band 108-137 MHz Aircraft Band 137-144 MHz Military Land...
Page 60
Appendix State Code Order 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32AK AL AR AZ CA CO CT DC DE FL GA IA ID IL IN KS KY LA MA MD ME MI MN MO MS MT NC ND NE NH NJ NMAlaska Alabama Arkansas Arizona California Colorado Connecticut District of Columbia Delaware Florida Georgia Iowa Idaho Illinois Indiana Kansas Kentucky Louisiana Massachusetts Maryland Maine Michigan Minnesota Missouri Mississippi Montana North Carolina North Dakota Nebraska New Hampshire New...