Page 21
17 Highway Patrol Scan Hold 1. When scanning stops on a desired frequency, press HOLD/RESUMEto hold on that frequency as long as you like. When in the HOLD mode, press the or key to step up or down the frequency. To step up or down rapidly, press and hold the or key. If you change into a frequency which is a control channel, the scanner may display the Active ID (When TRUNK mode is active). 2. To resume scanning, press HOLD/RESUME. Note: Highway Warning Alert does not work while in the HOLD...
Page 22
•Press MUTEto cancel One Moment Mute. •Press and hold MUTEfor two seconds to cancel Continuous Mute. You hear two beeps and the MUTE LED goes out. •Change states. The MUTE LED goes out after scanning starts. •Turn the scanner off and on. Note: If MUTEis pressed for less than 2 seconds during the Continuous Mute mode, nothing will be changed. Alert Light Adjustment The ALERT Light has three settings: Bright, Dim, and Off. Push FLASHto select Bright, Dim or Off. The ALERT Light flashes and the Alert Tone...
Page 23
19 You will experience a slight in the conversations you hear as the scannerchecks the Priority channels. You can cancel the priority check and the interruptions in the conversations by pressing HOLD/RESUMEto hold on the frequency. Note: The Highway Warning Alert is inoperative while the scanner is on Hold. Remember to press HOLD/RESUMEto return to normal priority-scan operation. Priority channel cannot be changed, but you can lock-out priority channels using L/O. Priority channels have been...
Page 24
Trunked Highway Frequency Trunked Highway frequencies are pre-programmed for each state. When the scanner finds the control channel data, the scanner begins to find any active IDs. If the scanner finds any ID, the active ID appears on the display and you will hear it. If you press the key while monitoring an ID, the scanner will check to see if any other IDs are active. If none are active, scanning resumes. When the scanner finds a control channel, it will stay on that control channel until...
Page 25
21 Private Bank Scanning Programming Frequencies into Channels Before the scanner begins Private Bank scanning, you must program a frequency into at least one channel. Program frequencies you purchased from your dealer, from various free and FCC-based sources on the internet, or from the Frequency guide included in BCT8 package. You will need to program each frequency into the scanner’s channels in order to hear these frequencies. 1. While Private Bank scanning is activated, press HOLD/RESUMEand enter...
Page 26
22 Duplicate Frequency Alert If you enter a frequency which has been stored in another channel, you will hear an error tone and the other channel displays. Press (decimal key) to clear and start again. ––– OR ––– Press Eagain to store the frequency in both channels. Note: The smallest channel appears on the display when you store same frequency in two or more channels. Memory Lock To avoid the accidental programming frequencies and talk group IDs, you can lock the memory with Memory Lock. Press and...
Page 27
23 Hold/Resume If you want to stop on a channel during scanning, press HOLD/RESUME. If you want to resume scanning, press HOLD/RESUME. Direct channel access: There are several ways to access a specific channel quickly. 1. Press HOLD/RESUME. 2. Using the keypad, enter the channel number. 3. Press HOLD/RESUMEagain. Note: You can also use the PVT, or key instead of pressing HOLD/RESUME. Channel Lockout You can lockout any channel so it is not checked during normal scanning. You can also restore the...
Page 28
Restoring All Locked-out Channels You can restore all locked-out channels in a bank only when a bank is selected for scan. If you have deselected a bank and you want to restore all of its locked-out channels using the steps below, you must press PVTuntil “PVT” appears and then enter the number of the bank on your keypad. 1. Press HOLD/RESUME. Note: You must be in Hold mode before restoring all locked-out channels. 2. Press and hold L/Ofor about 2 seconds. You will hear two beeps when all the channels...
Page 29
25 Service Scanning The service scan feature allows you to rotate through the following nine service banks. ➀Local Police and County Sheriffs *1 ➁Fire and Emergency Medical Service ➂News Media ➃Weather (NOAA, weather and Canadian Coast Guard broadcasts) ➄CB Band ➅Aircraft *2 ➆Railroads ➇Marine Band ➈Department of Transportation *1 *1) Frequencies are pre-programmed on every U.S. state. *2) Except Aeronautic Radio Navigation (108-117.9875 MHz) 1. Press SVCto select a Service. The current service bank...
Page 30
26 Band Search Setting a Search Band The BCT8 can search up to 13 separate frequency ranges to help you discover new stations in your area. To set a Search Bands, enter into the Band Search mode. 1. Press SRCH. The upper and lower limits of the Bands currently selected are on the display. 2. Use the or key to select the band you want to search. Wait for about two seconds and the scanner will begin searching that band. Or press HOLD/RESUMEto begin immediately. Notes:•You must set the Search Bands...