53 Motorola Reception Motorola Tracking There are really two types of Motorola trunking systems. These are usually referred to as Type I and Type II systems. Type I only occurs on some 800 MHz systems. All VHF, UHF and 900 MHz trunking systems use Type II. One important distinction between these two systems is the amount of data transmitted by each radio when its push-to-talk button (PTT) is pressed. Every radio in a trunked system is assigned a unique ID so the central site computer can identify it when...
Page 62
54 Fleet Map Programming If you have programmed a trunk tracking bank for Motorola type and press TRUNKto start Multi-Track, you will see user IDs display on your screen. Since the BC780XLT defaults to Type II systems, all the IDs will appear as numbers. However, if you notice a mix of odd and even user IDs, for example 6477, 2560, 6481, 6144, 1167, etc., then you are probably monitoring either a Type I or Hybrid systems. You may also notice that you are missing responses when you hold on an active ID....
Page 63
55 3. Select the size code for the first block using s, t, or VFO. 4. Press E, SELECT,or VFO. The next available block displays. 5. Repeat step 3 and 4 until you have selected a size code for each block. For details about each size code, see Fleet Map Size Codes in the Appendix. Programming a Hybrid System A Hybrid system is simply a Type I system with some blocks designated as Type II blocks. To program a Hybrid system, follow the steps listed in Programming a Fleet Map in the previous section....
Page 64
56 7. Enter a new offset channel with the keypad. Note: You can only input within a range of 380-759. 8. Press E. The display changes for entering the next base frequency. 9. To exit from this mode, press MENUrepeatedly. Note: • If the system is not tracking properly, you may need to try a new base frequency or offset channel or you may be missing frequencies from the system. • You can set up to three base, spacing and offsets for Motorola VHF/UHF trunked systems. 10. The offset channel for the first...
Page 65
57 Control Channel Only Mode When this function is activated, trunking is performed using control channel data only. Voice channel (also known as working channel) frequencies do not have to be programmed into memory. When using this feature, the scanner will display CC and channel activity indicator bars will not operate. This feature only applies to Motorola 800 MHz and 900 MHz systems. To turn this function on, choose Motorola Type-2 800 MHz or 900 MHz or TYPE 1 by selecting TRUNK DATA - BANK NO. -...
Page 66
58 Disconnect Tone Detect Option (End Code) When this function is disabled, the radio looks for squelch before returning to the control channel instead of waiting for the disconnect tone. Only in rare instances will you need to adjust the default settings. The condition to return to control channels depends on whether the signal is present or not. To set this function on/off, enter TRUNK DATA - BANK NO. - END CODE. BC780XLT1.qxd 10/08/2000 5:03 PM Page 58
Page 67
59 Remote Interface You can communicate and program your BC780XLT in numerous ways with peripheral devices using the Remote Interface Cable port. This radio offers the following modes: vSMARTSCAN MODE Automatically load frequencies, trunking talkgroups and fleetmaps from the Uniden National Frequency Database server into your scanner using an external modem or an internal modem included with a personal computer (PC). vREMOTE (PC Control) MODE Program and control your scanner remotely from a PC using...
Page 68
60 To connect Scanner to External Modem: Plug the scanner end of the RS232C straight interface cable into the remote port on the rear of your scanner. Plug the other end of the cable (DB-9 serial connector) into the external modem. You may need a DB-9 to DB-25 (or DB-9) null modem adapter, available at most computer stores. Of course, make sure your external modem is turned on. Make sure that you have a phone line plugged into the modem jack on the back. To perform the SmartScan Download: You can...
Page 69
61 6. After clearing, the DIAL STARTmessage appears. Press 1to start dialing. 7. If the connection is successful, the scanner starts frequency downloading. COMPLETEwill be displayed when your downloading is completed. 8. To start the scanner, turn the unit off then on. If downloading is not successful, one of the following error messages will appear. Modem Access Error: No Carrier: Telephone Line Busy: No Answer: Server Connect Error Data Idle Time Out Note: If the scanner does not display DOWNLOAD...
Page 70
62 Menu for SmartScan In the menu mode (SYSTEM DATA - SMART SCAN), you can change several parameters used for SmartScan. • Bank lock • Transfer speed • Flow control setting • Dial type Bank Lock SmartScanner will overwrite frequencies that you have already programmed into your scanner. To save the previously programmed frequencies, you can lock out specific banks prior to calling the database as follows: To turn on this feature, enter into the menu mode. 1. Press MENU. 2. Select SYSTEM DATAusing s, tor...