Page 31
23 1. After programming frequencies, simply press SCANto begin scanning. 2. The bank indicators selected for scanning appear in the display, and the bank being currently monitored flashes. You can deselect banks from active scanning by pressing their number on your keypad. The indicator for each deselected bank turns off, and the banks channels are not scanned. Note: One Bank must always be active. You cannot deactivate all ten banks at the same time. If you try to turn off all the banks, the first bank...
Page 32
24 Still another method of direct access to a specific channel: 1 Press MAN. 2 Press s or tto select the channel. (or press and hold sor tto scroll more quickly.) Lastly to step up through the channels one at a time, repeatedly press MAN. RF Attenuation Feature The BC 780XLT comes with an RF Attenuation feature. If youre near an unusually strong signal source, the signal may overload the scanner. The scanner may stop repeatedly on that signal and miss other transmissions. The RF Attenuation feature...
Page 33
25 5. Press sor tto select one of the delay periods provided and then press E.DLYappears on the display unless no delay has been set. 6. For Search mode, select SEARCH EVENT - DELAY, then set the delay period. Note: The delay periods are as follows: • None: Delay feature off • 1 sec.: Delays for 1 sec. before re-scanning • 2 sec.: Delays for 2 sec. before re-scanning • 4 sec.: Delays for 4 sec. before re-scanning • Infinite: Stays on until SCAN is pressed • -2 sec.: Stays for 2 sec. only before...
Page 34
26 3 . The scanner immediately resumes scanning because the locked out channel is no longer in the scanning sequence. Lockout Tips • Write down your locked-out channels and put in a convenient place in case you need to restore them. Restoring a Locked-out Channel 1. Press MAN. 2. Select a locked out channel. a. Enter the channel number. b. Then press MANagain. 3. Press L/Oto unlock the channel. The L/Oicon goes out. Restoring All Locked-out Channels You can restore all locked-out channels in a bank...
Page 35
27 Changing the Priority Channel You cannot eliminate the Priority Channel, but you can change it to any one of the 50 available channels in each bank. 1. Press MAN. 2. To select a new Priority Channel: a. Enter the channel number. b. Then press MANagain. 3. Press and hold PRIfor two seconds to designate this channel as your new Priority Channel. Two beeps indicate that the Priority channel has been changed. The Picon appears in the display. Note: • Priority in Trunking mode works just the same,...
Page 36
28 Setting a Search Range Note:First you must set the search ranges through the menu screen prior to any searching. The BC780XLT can search up to 10 separate frequency ranges to help you discover new stations in your area. To set a search range, enter into the menu mode. 1. Press MENU. 2. Press s or tto select SEARCH EVENTand then press E. 3. Press s or tto select SEARCH BANKand then press E. 4. Press s or tto select the desired bank number and then press E. 5. Press s or tto select EDIT RANGEand...
Page 37
29 Search Hold Feature 1. Press HOLD/sat anytime to stop the search. 2. Press HOLD/sto move to the next higher frequency. ––– OR ––– Press LIMIT/tto move down to the previous frequency. 3. Press SRCHto resume searching. Data Skip A scanner will normally stop on any transmission it receives. This means the BC780XLT will occasionally stop on data signals and unmodulated transmissions. You can automatically skip many of these types of transmissions during search. To activate the data skip feature, enter...
Page 38
30 Storing Search Frequencies You can quickly store any frequency you find during Search. Caution: You must select the channel in which you will store the frequency before entering the search mode. Otherwise, you may erase a stored frequency that you want to keep. 1. During search, press HOLD/swhen the scanner stops at the frequency you want to store. 2. Press Eto store the frequency in the channel you selected. Note: • If the frequency you want to store exists already, WARNINGappears on the display...
Page 39
31 Squelch (SQ) Mode The scanner can be set to the following SQ modes. • Carrier SQ mode (default setting) The scanner will stop on any transmission or squelch opening, regardless of whether any sub-audible tone has been programmed for the channel or search range. • Tone SQ mode The scanner will stop on any active frequency for which either no sub-audible tone has been programmed or for which the user-programmed sub-audible tone is also active. • Tone Search mode During any transmission, the scanner will...
Page 40
32 Note: • CTCSS: Continuous Tone Coded Squelch System. • DCS: Digital Coded Squelch. • For example, the scanner shows the following displays. • If the delay feature (-2 sec/-5 sec/-10 sec) has been set while in Tone search mode, it resumes scanning according to the delay setting. Additional Menu Options for Searching Each of these additional menu options apply to all banks with search ranges entered. If there is a bank that you do not want an option to apply, then simply press the bank number on the...