Page 1
RT-PRC014H-E4 Voyager™ II Rooftop Units Cooling-only TKD-TKH 155-175-200-250-265-290-340 Heat pump WKD-WKH 125-155-200-265-290-340 Cooling-only with gas-fi red heating YKD-YKH 155-175-200-250 Heat pump with gas-fi red heating DKD/DKH 125-155-200-265-290-340 R410A Refrigerant
Page 2
RT-PRC014H-E4 2 © 2014 Trane Table of Contents Features and Benefits ....................................................................................... 4 Compressors ...................................................................................................................4 ReliaTel™ Micro Controls ............................................................................................... 4 Drum And Tube Heat Exchanger...
Page 4
Compressors Voyager contains the best Scroll compressor technology available, in order to achieve the highest performance possible. The Trane Voyager™ rooftop has among the best COP in its class. All performances are Eurovent certi ed which provides the assurance of accurate performance and common comparison criteria ReliaTel™ Micro Controls The Micro provides unit control for heating, cooling and ventilating utilizing input from sensors that measure outdoor and indoor temperature. The Micro...
Page 5
Quality And Reliability The fan and idler arm assembly designs have been tested to over 300,000 cycles each. All of Voyager’s designs were rigorously rain tested at the factory to ensure water integrity. We perform a 100% coil leak test at the factory. The evaporator and condenser coils are leak tested at 1.4 MPa and pressure tested to 3.1 MPa. Every unit and its options receive a 100% unit run test before leaving the production line to make sure it lives up to Trane r equirements. Ease Of...
Page 6
One Zone Sensor option has central control panel lights which indicate the mode the unit is in and possible diagnostic information (dirty lters for example). Figure 3 – RTRM (ReliaTel™ Refrigeration Module) Standardized Components Components are placed in the same location for all Voyager units. Easy Access Lo w Voltage Terminal Board The thermostat wires must be connected to the terminals located on the main board. Single Point Power A single electrical connection powers the unit. Figure 4 –...
Page 7
RT-PRC014H-E4 7 Indoor Air Quality Filters - all rooftops are shipped with throwaway lters to be used during the rst days of operation (usually the job site is not completely clean, and high ef ciency lters would get dirty in a few hours - this would be a waste of money) or G4/EU4 lters for regular operation.Panels in the indoor air section have a re- resistant (MO) aluminum foil-faced insulation. There is no more insulation paticules carried in the air. It can be cleaned which is paricuarly...
Page 8
RT-PRC014H-E4 8 Options and Accessories Table 1 TKD TKH WKD WKH YKD YKH DKD DKH Application Description Incompatible with FRESH AIR OPTIONS 0-25% manual fresh air hoodAAAAAAAAFresh air needed in the building, up to 25% of the nominal airfl ow.Manually sets a permanent amount of fresh air in the unit, between 0-25% of the nominal airfl ow.Economizer, 0-50% motorized hood, CO 2 sensor, remote potentiometer. 0-50% motorized fresh air hoodOOOOOOOOFresh air needed in the buil- ding, up to 50% of...
Page 9
RT-PRC014H-E4 9 Options and Accessories TKD TKH WKD WKH YKD YKH DKD DKH Application Description Incompatible with VENTILATION EU4 fi lters OOOOOOOOTo fi lter the air.Washable media, treat the return and fresh air, 90% gravimetrical effi ciency. EU4+EU7 fi ltersOOOOOOOOTo fi lter the air.50mm+50mm Galvanized steel frame fi lters. Washable media for EU4 pre-fi lter, EU7 provides 85% opacimetric effi ciency. Clogged fi l- ter detectorOOOOOOOOTo facilitate maintenance of the fi lters.When the pressure drop of...
Page 10
RT-PRC014H-E4 10 TKD TKH WKD WKH YKD YKH DKD DKH Application Description Incompatible with CONTROL Reliatel™ Options Module (RTOM)OOOOOOOORequired for some optional ReliaTel™ devices (frostat, clogged fi lter switch, fan failure switch, discharge air sensor (DAS) used for supply air tempering and ICS input data, smoke detector, exter- nal on/off switch).Communication interface between the ReliaTel™ Refrigeration Module (RTRM) and some options. TCI-R OOOOOOOOTo communicate with Trane Integrated...