4/00, Tecra Toshiba TRRPage 22Tecra 750 Series Disassembly Overview, (cont.) To remove the fan, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, HDD pack, optional memory module, modem board, backup and RTC batteries, keyboard, membrane switch, top cover with display assembly, and system board. 3.Turn the system board upside down and remove the tape securing the fan cable. 4.Disconnect the fan cable from PJ550 on the system board. 5.Turn the system board right side up and remove two M2.5x4 screws. 6.Lift out the fan. To remove the middle frame, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, HDD pack, optional memory module, modem board, backup and RTC batteries, keyboard, membrane switch, top cover with display assembly, and system board. 3.Remove two M2.5x4 screws and one M2.5x8 screw securing the Selectable Bay top cover to the middle frame. 4.Two positioning pins fit into holes on the Selectable Bay top cover. Pry the cover free of the pins then lift off the cover. 5.Disconnect two secondary battery cables from the I/O board. 6.Remove six M2.5x8 screws and one M2.5x4 screw securing the middle frame to the bottom cover. 7.Pull out the Selectable Bay release lever and set the Selectable Bay lock to the lock position. CAUTION: If you remove the middle frame while the Selectable Bay lock is unlocked, the I/O board will be damaged. NOTE: Make sure the screw in the memory slot has been removed. 8.Lift off the PC card slot cover and lift out the middle frame. 9.Remove one M2x3 screw securing the bracket over the probe pin harness. 10.Remove two M2x5 screws securing the probe pin harness to the middle frame. 11.Lift out the probe pin harness and note how the cables are threaded.ê
Toshiba TRR4/00, Tecra Page 23Tecra 750 Series Disassembly Overview, (cont.) To install the middle frame, follow the steps below. 1.Reroute the cables and replace the probe pin harness. 2.Secure the probe pin harness to the middle frame with two M2x5 screws. 3.Secure the bracket over the probe pin harness with one M2x3 screw. 4.Make sure the Selectable Bay release lever is extended and the Selectable Bay lock is in the lock position. 5.Seat the middle frame and make sure a small tongue on the middle frame’s Selectable Bay locking mechanism fits into a corresponding notch on the external Selectable Bay lock. 6.Secure one M2.5x8 screw next to the Selectable Bay lock arm, then secure the other five M2.5x8 screws. 7.Secure the middle frame to the bottom cover with one M2.5x4 screw. 8.Seat the PC card slot cover. 9.Secure the Selectable Bay top cover with two M2.5x4 screws and one M2.5x8 screw. 10.Connect two secondary battery cables to the I/O board. 11.Install the battery pack, HDD pack, optional memory module, modem board, backup and RTC batteries, keyboard, membrane switch, top cover with display assembly, and system board. 5.Lift out the I/O board. 6.Lift out the base shield assembly. 4.Remove one M2x6 screw securing the I/O board to the bottom cover. To remove the I/O board, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, HDD pack, optional memory module, modem board, backup and RTC batteries, keyboard, membrane switch, top cover with display assembly, system board, and middle frame. 3.Remove the battery pack jumper as follows: (a)From the bottom of the battery pack slot, push up on the battery jumper contact and slide it forward. (b)Press down on the jumper as shown in the Figure below and slide the jumper out to remove it.î
4/00, Tecra Toshiba TRRPage 24Tecra 750 Series Disassembly Overview, (cont.) To remove the display mask, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack. 3.Remove two rubber seals at the bottom corners of the display assembly. 4.Remove two M2.5x6 screws that were covered by the rubber seals. NOTE: Support the display with your hand when you remove the screws. 5.Release 18 latches along the edges of the display mask. Begin at the top (six latches), continue along the sides (four latches on each side) and the bottom (four latches). 6.Remove the display mask.î To remove the FL inverter board, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, and the display mask. 3.Lay the display panel on its back and remove one M2x4 screw securing the microphone and its ground cable. 4.Remove two M2.5x6 screws securing the FL inverter board and its ground cable. 5.Rotate out the top end of the FL inverter board and disconnect the FL cable from CN2. 6.Disconnect the FL inverter cable from CN1 and lift out the FL inverter board.î
Toshiba TRR4/00, Tecra Page 25Tecra 750 Series Disassembly Overview, (cont.) NOTE: Be careful not to apply pressure to the ICs along the edge of the LCD module. The ICs are easily damaged. To remove the LCD module, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, display mask, and FL inverter board. 3.Remove four M2.5x8 screws securing the LCD module to the display assem- bly. 4.Carefully rotate out the top of the LCD module enough to access the display cable, remove the tape, and disconnect the cable. 5.Lift out the LCD Module. CAUTION: The FL cable, FL inverter cable, and microphone cable will only fit one way. Be certain you note how the cables are routed so they can be replaced accurately. To remove the microphone, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, display mask, FL inverter board, and LCD module. 3.Lift the microphone holder out of its seat. Remove the microphone from the microphone holder. 4.Lay the top cover and display assembly down so that the bottom of the top cover lies flat and faces up. 5.Remove one M2x4 screw, under the cable, securing the hinge cover and one M2.5x6 screw securing the plastic cable guide. 6.Remove the tape and release the plastic cable guide, covering the FL inverter insulator, microphone cable, and Fl inverter cable, from the top cover at the top right corner of the left speaker cable groove. 7.Press on the small end of the cable guide, toward the case, to free it. 8.Lift the cable guide straight up, pull the microphone cable out of the cable guide, and remove the microphone. NOTE: Grasp the top cover by the sides when you rotate it up. Do not pull at the center.ê
4/00, Tecra Toshiba TRRPage 26Tecra 750 Series Disassembly Overview, (cont.) CAUTION: When you remove the FL, be careful not to let any dust or other foreign matter contaminate the LCD panel. Any contamination can affect the performance of the unit. To remove the FL, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, display mask, FL inverter board, LCD module, and microphone. 3.Remove the tape covering the FL cable. 4.Remove one thin-head silver screw and two M2x4 silver screws securing the metal FL cover. 5.Carefully slide the metal FL cover about 2 mm away from the FL cables and lift it up. 6.Lift out the FL cable and the FL.î í CAUTION: When you remove the FL, be careful not to let any dust or other foreign matter contaminate the LCD panel. Any contamination can affect the performance of the unit. To remove the FL, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, display mask, FL inverter board, LCD module, and microphone. 3.Remove two strips of tape securing the FL cable and metal FL cover. 4.Remove two thin-head screws securing the metal FL cover. 5.Slide the metal FL cover forward about 2 mm and lift it off. 6.Lift out the FL cable and the FL holder. 7.Remove the FL tube from the FL holder.í è
Toshiba TRR4/00, Tecra Page 27Tecra 750 Series Disassembly Overview, (cont.) CAUTION: When you remove the FL, be careful not to let any dust or other foreign matter contaminate the LCD panel. Any contamination can affect the performance of the unit. To remove the FL, follow the steps below. 1.Turn off the power to the computer. Disconnect the AC adapter and all external cables connected to the computer. 2.Remove the battery pack, display mask, FL inverter board, LCD module, and microphone. 3.Remove one strip of tape securing the FL cable to the LCD frame and lift the FL cable. 4.Remove two M2x4 thin-head silver screws, one M2x1 thin-head black screw, and four thin-head silver screws. 5.Carefully peel up the insulator adhered to the circuit boards and ICs. 6.Disconnect the flexible cable from the larger board and press down the connector flap to avoid damage. 7.Lift up the center of the metal FL cover until two latches are released. 8.Insert a thin object such as the end of tweezers under the metal FL cover until the cover is freed. 9.Lift up on the metal projections and pull the FL cover slightly forward, slide it left, and lift it out. 10.Carefully lift up the white sheet covering the FL. 11.Lift out the pink FL cable connector. 12.Lift the white FL cable out of its groove to remove the FL with cables.î ê í Images continued on the next pageî
4/00, Tecra Toshiba TRRPage 28Tecra 750 Series Disassembly Overview, (cont.)ê Removing the FL, continued.