Page 201

01 GENERAL 
01 .Ol Thus section describes the maintenance 
procedures used for the diagnosis of faults in this 
electronic key telephone system. Faults are clas- 
sified and then cleared by replacing the apparatus 
and performing operational tests in the se- 
quences prescribed by the fault clearing flow- 
charts in Paragraph 05. 
02 FAULT CLASSIFICATION 
02.01 
A Fault Classification Flowchart is pro- 
vided to ensure that fault clearing is pursued in a 
logical sequence (Chart No. 1). 
02.02 An...

Page 202

FAULT FIBJDING 
SECTION 500-036-500 
JANUARY 1988 
DO NOT: 
l Drop a PCB. 
l Stack one PC6 on top of another. 
l Handle a PCB wrthout discharging any static 
electrrcity from your person by touching the 
grounded HKSU. 
l Touch PCB contacts with your fingers. 
IMPORTANT! 
If the fault is not cleared by substituting a 
PCB, the original PC6 must be reinstalled in 
the HKSU before trying another PCB. 
04 
DEFECTIVE APPARATUS RETURNS 
04.01 When a defective system apparatus is 
shtpped for repair, the...

Page 203

4) For the MDF-to-EKT cable, a more precise 
check IS made using an ohmmeter. 
TABLE B 
STATION CABLE CONTINUITY CHECK 
USING VOLTMETER 
FROM TO VOLTAGE* 
Pair Wire COb Pair Wwe CC&Or 
1 T Green 
2 T Black 24 
1 R Red 2 T Black 24 
1 T Grl??i- 2 R Yellow 24 
1 R Red 2 R Yellov: 24 
1 T 
Green 1 .R Red 0 
2 T 
Red 
2 R Yellow 
0 
3 T While 3 R 
Blue 0 
3 T Whffe 1 R Red 0 
3 3 Blue 1 R Red 0 
3 T Wh!lE 1 T Green 0 
3 R Blue 1 T Green 0 
3 T Whsre 2 T 
Black 0 
,3 R Blue 2 T Black 0 
3 T Whlre 2 A Yellow 0...

Page 204

CHART NO. 1 
FAULT CLASSIFICATION 
Please read 
General Malnrenance 
Informalton before 
proceeding. 
1 
( ST?“‘) 
/ Does  
/-  
YES 
NO ------. 
To 
A 
STA 
FAULT FINDING 
SECTION 500-036-500 
JANUARY 1988 
Uoes the 
taulr affecr all 
Lnecn 
CI breakers 
power fndl  

Page 205

CHART NO. 1 
FAULT CLASSIFICATION 
(cont.) 
F ram 
1 NO 
f 
To 
To 
To 
NO 
To 
c2 
0 
Page 6 
-5- FAULT FINDING 
SECTION 500~D36-500 
JANUARY 1988  

Page 206

FAULT FINDING 
SECTION 500-036-500 
JANUARY 1988 
CHART NO. 1 
FAULT CLASSIFICATION 
(cont.) 
From 
I NO 
1 NO 
1 NO 
1 NO 
Fault should have 
been classified. 
Return to Page 4. 
-6-  

Page 207

CHART NO. 2 
From POWER FAULTS 
Go to Page 4 
Is the HKSU 
l Power swatch off. l Operate the 24V 
circuit breaker 
on the HKSU. 
l Power switch on. . Replace HKSU. 
l Tag defective 
HKSU and returr 
for repaIr. 
I 1 YES  . Power switch off. 
. Operate the 24V 
i 
c!rcuIt breaker 
on the HKSU. 
l Power switch on 
FAULT FINDING 
SECTION 500-036-500 
JANUARY 1988 
Input IO the HKS’L 
23.2- 20.2V7 
NO 
the HKSU 23.2 
l Power switch off. 
. Remove PCBs 
except the SMAUI 
VMAU. 
l Operate circuit 
breakers. 
l...

Page 208

From 
Pl 
0 Page 7 
NO 
Replace the 
HKSU. 
FAULT FINDING 
SECTION 500-036-500 
JANUARY 1988 
CHART NO. 2 
POWER FAULTS (cont.1 
From 
one at a time. 
l Take note of 
failure If it 
occurs and replace 
l Be sure to 
switch power 
Tag defectwe 
PCBIsl and return 
for repaw. return for repalr. 
l Check power 
supply fuses and 
AC source. 
l Replace or repajr 
as necessary. 
23 END 
-8- 
l Replace power 
,.’ SUPPlY. 
l Tag defectwe 
unit and return 
for repair. 
c-4 END  

Page 209

From 
STA 
c Page 4 
_c-c 
CHART NO. 3 
STATION FAULTS 
HVSU in EKT 
F ram 
To 
Tag the 
defectwe unltls) ~ YES 
and return 
for repalr. 
YES 
END Verify statton 
cable per Tables Stallon port 
on another 
FAULT FINDING 
SECTION MO-036490 
JANUARY 1988 
To 
Replace 
Replace 
aPP:oprlatr 
svcu. awromare 
SSTU. 
YES J 
v 
END  

Page 210

1 
FAULT FINDING 
SECTION 500-036-500 
JANUARY 1988 
CHART NO. 4 
H KSU FAULTS 
From 
Remove’ 
scou!vcou. 
SEPU, SMOU. 
i- . Reinstall all 
I 
Replace HKSU. Tag defective 
PCBkl and 
return for repair. 
Tag defective 
H KSU and 
return for 
repair. 
-lO-  