Page 11
STRATA DK GENERAL DESCRIPTION DECEMBER 1990 TABLE B GENERAL REQUIREMENTS -. Primary power Input AC AC frequency DK24 power supply DK56 power supply DK96 power supply Environmental specifications Operating temperature Operating humidity Storage temperature Power supply DC voltage output specification a5 w 135VAC 50/60 Hz 65 watts 140 watts 230 watts 32 ..a 104°F (0 - 40°C) 20 - 60% relative humidity without condensation - 4 M 158°F (-20 M 70°C) -24VDC: (-26.3 w -27.8VDC) +5VDC:...
Page 12
STRATA DK GENERAL DESCRIPTION DECEMBER 1990 TABLE C RESERVE POWER TIME TYPICAL RESERVE POWER DURATION ESTIMATES * Time is estimated with the following considerations: 1. Batteries have full charge at start of operation. 2. Batteries (2) are connected in series. 8. Batteries are 12VDC, rated at 80 amp/hours each. 4. System is operating at full load traffic with LCD phones. 5. Batteries used for this test are gel-Cell and maintenance-free. Reserve duration will vary &pending upon battery type,...
Page 13
STRATA DK GENERAL DESCRIPTION DECEMBER 1990 can also be upgraded with off-hook call anounce, loud ringing bell, and headset inter- face capability. l Simultaneous Voice and Data: Digital telephones may be upgraded with an inte- grated data interface unit (PDIU-DI) to receive and transmit simultaneous voice and data; data and voice calls can be made independently of each other. The PDIU-DI (Figure 5) is easily installed, replacing the usual digital telephone base. Asynchronous data devices,...
Page 14
It is normally used on systems with a heavy volume of incoming calls. A DDSS console may be used with any digital station connected to the first circuit on the digital telephone inter- face PCB (PDKU). Up to four DDSS consoles can be supported with a PCTU3 PCB. 0 0 0 DDSS consoles are equipped with auto- matic line hold, and voice or tone signaling capability. The consoles have 60 flexible buttons, each with an associated LED (the DDSS button LEDs will light red or green depending on the...
Page 15
STRATA DK GENERAL DESCRIPTION DECEMBER 1990 ” FIGURE 7-IO-button ELECTRONIC TELEPHONE FIGURE 8-20-button ELECTRONIC TELEPHONE l Called Station Messaging l Calling Station Messaging l Busy Station Messagingt l Group/Remote Station Messaging-t l Busy Lamp Field (BLF) Indication l CO Line Identification l Speed Dial Memo l Timed Reminders with Messages l Intercom User Name/Number Display l Call Duration Display System software allows the customer to assign feature buttons on all electronic...
Page 16
the phone’s ring. On voice first intercom calls, the HESB amplifies the caller’s voice announcement. See the External Speaker option. l Most standard headsets plug into the HHEU jack and are compatible with the electronic telephone. l An electronic telephone may use all avail- able upgrade options simultaneously. For example, the same station may be upgrad- ed with a DSS console, OCA, a loud ring- ing bell, and a headset. Direct Station Selection Console: The Direct Station Selection (DSS)...
Page 17
STRATA DK GENERAL DESCRIPTION DECEMBER 1990 TABLED DATA INTERFACE SPECIFICATIONS = ITEM SPECIFICATIONS Terminal Interface Specification RS-232C (EIA) V.24/V.28 (CCITT) Data Transmission Speed Flow Control Automatic Dialing Up to 19.2kbps, asynchronous Half and full duplex, utilizing RTS/CTS/CD control leads Based on AT commands: l Data speed of AT command is 300,600, 1200,2400,4800, or 9600 l Data bit: 7 or 8 bits l Stop bit: 1 or 2 bits . Parity bit: even, odd, or no parity Maximum...
Page 18
STRATA DK GENERALDESCRIPTION DECEMBER1990 one 2B+D station port on a PDKU (see Printed Circuit Boards) and will function on one wire NOTES: 1. The PDIU-DS will function with all slots, except slots 11 u 14 in DK96. 2. Modems, printers, and mainframes are connected to the standard RS-232 DB25 connector on the PDIU-DS (see Table 0). Door Phone: In one of its most popular applica- tions, the door phone (Figure 12) mounts out- side a building, next to a locked door whose entry requires...
Page 19
STRATADK GENERALDESCRIPTION DECEMBER1990 FlGURE14-EXTERNALSPEAKER(HESB) l Amplified Talkback Speaker: When used in conjunction with external page, an HESB can be installed as a talkback device. The HESB is connected to the door phone, which is used as a micro- phone to provide talkback capability. l Loud Ringing Bell: Allows the voice/tone of a paging/ringing call to any digital tele- phone or 6500-series electronic tele- phone to be amplified. When an HESB is connected as a loud ringing...
Page 20
STRATA DK GENERAL DESCRIPTION DECEMBER 1990 TABLE F NETWORK REQUIREMENTS PCB Facility Ringer Interface Code Network Jack Equivalence PCOU (Loop start line) 02LS2 RJ14C 0.2B PEMU (Type I, TIE line) 2-wire TLllM RJ2EX N/A 4-wire TL31 M RJ2GX N/A PESU/PSTU (Off-premises station) OL13A RJ21 X N/A (see note) NOTE: On PEW, circuits I and 2 only provide off-premises capability. Power Failure Transfer Unit: An optional exter- nal power failure transfer unit (DPFT) may be connected to the...