Have a look at the manual Toshiba Strata Dk Personal Computer Data Interface User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 566 Toshiba manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Mode Definitions Data Communications Mode Strata DK PC/Data Interface 5/9933 RPCI/DIU Data Speed (Baud Rate) DIUs pass data at a baud rate of up to 19,200 bits per second (bps), if the call was established by manually dialing from a data telephone. If the call was established with AT commands from a PC or terminal, the DIU passes data at up to 9600 bps. The baud rate of a DIU is transparent when originating calls with the data telephone or when receiving data calls, manually and automatically. When originating data calls with AT commands from a PC or terminal, the DIU speed is the same as the rate of the first AT command. When answering data calls with the ATA command string, the DIU baud rate is the same as the command string; the AT command baud rate is determined by software running the terminal or PC. RPCI/DIU Default Communication Parameters Default parameters for the DIUs are shown below; however, they are transparent or changed by the first AT commands issued, as described above. A DIU assumes these default parameters when power is initially applied to it, or after the modular cord is disconnected and then reconnected. ©Baud rate: 1200 bps ©Data bits: 8 bits ©Parity: none ©Stop bits: 1 stop bit Table 5 DIU AT Command Set CommandDescription ATCommand prefix ATDY...YVoice call to telephone number (Y…Y = any number of digits), internal or external ATDDXXXXData call to DIU station number XXXX (1~4 digits) EnterCarriage return character AGo into the answer mode; attempt to go to Communication Mode A/Re-execute previous command line; not preceded with AT nor followed by Enter DGo into originate mode; dial number that follows; attempt to go to on-line state
Mode Definitions Data Communications Mode 34Strata DK PC/Data Interface 5/99 NoteA DIU assumes the V1 default value when power is initially applied to it or when the modular line cord is disconnected and then reconnected. EODisable character echo in Command Mode E1Enable character echo in Command Mode H0Go on-hook (hang up) H1Go off-hook OGo to Communication Mode Q0DIU returns Result Codes Q1DIU does not return Result Codes SR = nSet Register “R” to value “n” (R = 0~12) SR?Display value stored in Register “R” (R = 0~12) V0Display Result Codes in numeric form V1Display Result Codes in words X0Enable features represented by Result Codes 0~4 X1Enable features represented by Result Codes 0~7, 10~12 X2Enable features represented by Result Codes 0 ~ 5, 10 ~ 12 X3Enable features represented by Result Codes 0~7, 10~12 X4Enable features represented by Result Codes 0~7, 10~12 Table 5 DIU AT Command Set (continued) CommandDescription
Mode Definitions Data Communications Mode Strata DK PC/Data Interface 5/9935 Table 6 DIU Result Code Set No.WordDescription 0OK Command executed 1Connect Connection at 0 to 300 bps 2Ring Ring Signal Detected 3No Carrier Carrier signal not detected, or lost 4ErrorInvalid command, checksum. Error in command line, or command line exceeds 255 characters 5Connect 1200 Connection at 1200 bps 7Busy Busy signal detected 10Connect 2400 Connection at 2400 bps 11Connect 4800 Connection at 4800 bps 12Connect 9600 Connection at 9600 bps Table 7 DIU S-Register Set RegisterRangeDescription S00~255 rings Select ring to answer on specific number of rings S10~255 rings Ring count (increment with each ring) S20~127 ASCII Define escape sequence character S30~127 ASCII Define carriage return character S40~127 ASCII Define line feed character S50~32, 0~127 ASCII Define back space character S71~255 sec. Select wait time for carrier/dial tone S91~255 sec. Select carrier detect response time S101~255 sec. Select-delay between carrier loss/hang-up S120~255 sec. Define escape sequence guard time
Mode Definitions Data Communications Mode 36Strata DK PC/Data Interface 5/99 NoteA DIU assumes these default values when power is initially applied to it or when the modular line cord is disconnected and then reconnected. Table 8 Default Values RegisterVa l ueS-Register Control S0Auto ring enabled S0 = 1 S10 rings S1 = 0 S2ASCII 43 S2 = 43 S3ASCII 13 S3 = 13 S4ASCII 10 S4 = 10 S5ASCII 08 S5 = 8 S730 sec. S7 = 30 S90.6 sec. S9 = 6 S100.7 sec. S10 = 7 S121 sec. S12 = 50 Table 9 DIU Dialing Modifier Set ModifierDescription 0~9*#Digits/characters for dialing ABCDDigits/characters for dialing PPulse dial TTone dial ,Delay processing of next character (1 second) !Hookflash ;Return to Command Mode after dialing
Strata DK PC/Data Interface 5/9937 Index B baud rate,7 C call data call while on a voice call, 14, 15 data device,10 from data telephone,12 from the externa PC or terminal,21 from your PC or terminal,11 terminate,10 voice call while on a data call,14 CO line,15, 26 CO line access codes,28 communication parameters,7 options,7 connect LED,6 D data bits,8 data call,3, 10, 12, 14, 24 data communications command mode, 30 mode (on-line state), 32 data communications mode,29 data release,3, 10, 12, 13, 15, 19, 27 default values,36 dial internal modem from your PC or terminal, 17 dialing modifiers,30 DIU dialing modifier set,36 DIU S-register set,35 H hardware requirements,2 hold,15 M modem,3, 18, 24 P parity,8 power LED,6 R ready LED,6 result codes,30 RPCI/DIU default communication parameters, 33
Index S ~ V 38Strata DK PC/Data Interface 5/99 S spkr,16, 27 s-registers,31 stop bits,8 switch between data communications and TAPI modes, 29 T terminate a call data connection state, 27 from data telephones,13, 19 from external PC or terminal,22 from PC or terminal,13 voice connection state,27 voice or data,15 V verify communications,11 from your external PC or terminal,20 from your PC or terminal,16