    							Mode Definitions
    Data Communications Mode
    Strata DK PC/Data Interface 5/9933
    RPCI/DIU Data Speed (Baud Rate) 
    DIUs pass data at a baud rate of up to 19,200 bits per second (bps), if the call was 
    established by manually dialing from a data telephone. If the call was established with 
    AT commands from a PC or terminal, the DIU passes data at up to 9600 bps. The baud 
    rate of a DIU is transparent when originating calls with the data telephone or when 
    receiving data calls, manually and automatically. When originating data calls with AT 
    commands from a PC or terminal, the DIU speed is the same as the rate of the first AT 
    command. When answering data calls with the ATA command string, the DIU baud 
    rate is the same as the command string; the AT command baud rate is determined by 
    software running the terminal or PC.
    RPCI/DIU Default Communication Parameters
    Default parameters for the DIUs are shown below; however, they are transparent or 
    changed by the first AT commands issued, as described above. A DIU assumes these 
    default parameters when power is initially applied to it, or after the modular cord is 
    disconnected and then reconnected.
    ©Baud rate: 1200 bps
    ©Data bits: 8 bits
    ©Parity: none
    ©Stop bits: 1 stop bit 
    Table 5 DIU AT Command Set 
    CommandDescription
    ATCommand prefix
    ATDY...YVoice call to telephone number (Y…Y = any number of digits), internal or external 
    ATDDXXXXData call to DIU station number XXXX (1~4 digits)
    EnterCarriage return character
    AGo into the answer mode; attempt to go to Communication Mode
    A/Re-execute previous command line; not preceded with AT nor followed by Enter 
    DGo into originate mode; dial number that follows; attempt to go to on-line state 
    						
    							Mode Definitions
    Data Communications Mode
    34Strata DK PC/Data Interface 5/99
    NoteA DIU assumes the V1 default value when power is initially applied to it or 
    when the modular line cord is disconnected and then reconnected.
    EODisable character echo in Command Mode
    E1Enable character echo in Command Mode
    H0Go on-hook (hang up)
    H1Go off-hook
    OGo to Communication Mode
    Q0DIU returns Result Codes
    Q1DIU does not return Result Codes
    SR = nSet Register “R” to value “n” (R = 0~12)
    SR?Display value stored in Register “R” (R = 0~12)
    V0Display Result Codes in numeric form
    V1Display Result Codes in words
    X0Enable features represented by Result Codes 0~4
    X1Enable features represented by Result Codes 0~7, 10~12
    X2Enable features represented by Result Codes 0 ~ 5, 10 ~ 12
    X3Enable features represented by Result Codes 0~7, 10~12
    X4Enable features represented by Result Codes 0~7, 10~12 Table 5 DIU AT Command Set 
    (continued)
    CommandDescription 
    						
    							Mode Definitions
    Data Communications Mode
    Strata DK PC/Data Interface 5/9935
    Table 6 DIU Result Code Set
    No.WordDescription
    0OK Command executed
    1Connect Connection at 0 to 300 bps
    2Ring Ring Signal Detected
    3No Carrier Carrier signal not detected, or lost
    4ErrorInvalid command, checksum. Error in command line, or 
    command line exceeds 255 characters
    5Connect 1200 Connection at 1200 bps
    7Busy Busy signal detected
    10Connect 2400 Connection at 2400 bps
    11Connect 4800 Connection at 4800 bps
    12Connect 9600 Connection at 9600 bps
    Table 7 DIU S-Register Set
    RegisterRangeDescription
    S00~255 rings Select ring to answer on specific number of rings
    S10~255 rings Ring count (increment with each ring)
    S20~127 ASCII Define escape sequence character
    S30~127 ASCII Define carriage return character
    S40~127 ASCII Define line feed character
    S50~32, 0~127 ASCII Define back space character
    S71~255 sec. Select wait time for carrier/dial tone
    S91~255 sec. Select carrier detect response time
    S101~255 sec. Select-delay between carrier loss/hang-up
    S120~255 sec. Define escape sequence guard time 
    						
    							Mode Definitions
    Data Communications Mode
    36Strata DK PC/Data Interface 5/99
    NoteA DIU assumes these default values when power is initially applied to it or 
    when the modular line cord is disconnected and then reconnected.
    Table 8 Default Values
    RegisterVa l ueS-Register Control
    S0Auto ring enabled S0 = 1
    S10 rings S1 = 0
    S2ASCII 43 S2 = 43
    S3ASCII 13 S3 = 13
    S4ASCII 10 S4 = 10
    S5ASCII 08 S5 = 8
    S730 sec. S7 = 30
    S90.6 sec. S9 = 6
    S100.7 sec. S10 = 7
    S121 sec. S12 = 50
    Table 9 DIU Dialing Modifier Set
    ModifierDescription
    0~9*#Digits/characters for dialing
    ABCDDigits/characters for dialing
    PPulse dial
    TTone dial
    ,Delay processing of next character (1 second)
    !Hookflash
    ;Return to Command Mode after dialing 
    						
    							Strata DK PC/Data Interface 5/9937
    Index
    B
    baud rate,7
    C
    call
    data call while on a voice call,
    14, 15
    data device,10
    from data telephone,12
    from the externa PC or terminal,21
    from your PC or terminal,11
    terminate,10
    voice call while on a data call,14
    CO line,15, 26
    CO line access codes,28
    communication parameters,7
    options,7
    connect LED,6
    D
    data bits,8
    data call,3, 10, 12, 14, 24
    data communications
    command mode,
    30
    mode
    (on-line state),
    32
    data communications mode,29
    data release,3, 10, 12, 13, 15, 19, 27
    default values,36
    dial internal modem from your PC or 
    terminal,
    17
    dialing modifiers,30
    DIU dialing modifier set,36
    DIU S-register set,35
    H
    hardware requirements,2
    hold,15
    M
    modem,3, 18, 24
    P
    parity,8
    power LED,6
    R
    ready LED,6
    result codes,30
    RPCI/DIU default communication 
    parameters,
    33 
    						
    							Index
    S ~ V
    38Strata DK PC/Data Interface 5/99
    S
    spkr,16, 27
    s-registers,31
    stop bits,8
    switch between data communications and 
    TAPI modes,
    29
    T
    terminate a call
    data connection state,
    27
    from data telephones,13, 19
    from external PC or terminal,22
    from PC or terminal,13
    voice connection state,27
    voice or data,15
    V
    verify communications,11
    from your external PC or terminal,20
    from your PC or terminal,16 
    						
    All Toshiba manuals Comments (0)

    Related Manuals for Toshiba Strata Dk Personal Computer Data Interface User Guide