Telecommunication Systems Division May 1999 Digital Business Telephone Systems Personal Computer/Data Interface User Guide
Publication InformationToshiba America Information Systems, Inc., Telecommunication Systems Division, reserves the right, without prior notice, to revise this information publication for any reason, including, but not limited to, utilization of new advances in the state of technical arts or to simply change the design of this document. Further, Toshiba America Information Systems, Inc., Telecommunication Systems Division, also reserves the right, without prior notice, to make such changes in equipment design or components as engineering or manufacturing methods may warrant. DKA-UG-PC/DIUVC 4016165 Version C, May 1999 Version B.1, November 1998 Version B, October 1997 Version A, September 1996 © Copyright 1999 Toshiba America Information Systems, Inc. Telecommunication Systems Division All rights reserved. No part of this manual, covered by the copyrights hereon, may be reproduced in any form or by any means—graphic, electronic, or mechanical, including recording, taping, photocopying, or information retrieval systems—without express written permission of the publisher of this material. Strata is a registered trademark of Toshiba Corporation. Trademarks, registered trademarks, and service marks are the property of their respective owners.
Strata DK PC/Data Interface 5/99i Contents Introduction Organization ............................................................................................................... iv Conventions ................................................................................................................. v Mnemonics ................................................................................................................ vii Related Documents .................................................................................................... vii Chapter 1 – The Grand Tour Hardware Requirements .............................................................................................. 2 Integrated Data Interface Unit (RPCI-DI) ................................................................... 2 RPCI-DI Buttons and LEDs ..................................................................................... 3 Stand-alone Data Interface Unit (PDIU-DS) Connections .......................................... 5 Communication Parameters ......................................................................................... 7 Chapter 2 – Features Data Call to Internal Printer or Other Data Device ..................................................... 9 Data Call to Another Internal Data Telephone’s PC or Terminal ............................. 10 Simultaneous Voice and Data Calls .......................................................................... 14 Voice Call While On Data Call .............................................................................. 14 Data Call While On a Voice Call ........................................................................... 14 Data Call to Data Telephone While on a Voice Call to Another Telephone ......... 15 Outgoing Data Call .................................................................................................... 16 Dialing Through the System Modem Pool ............................................................. 16
Contents Chapter 3 - Mode Definitions iiStrata DK PC/Data Interface 5/99 Incoming Data Call (External) ................................................................................... 20 Switch From Outside Voice Call to Data Call ........................................................... 23 Switch Back to the Voice Call Using Privacy Override ........................................ 25 Switch Back to the Voice Call Using Executive Override ..................................... 26 Personal Computer Dialing of Voice Calls ............................................................... 27 Chapter 3 – Mode Definitions Data Communications Mode ..................................................................................... 29 Switching Between Data Communications and TAPI Modes ............................... 29 Data Communications Command Mode ................................................................ 30 Data Communications Mode (On-line state) .......................................................... 32 Switching Between Data Communication Modes .................................................. 32 RPCI/DIU Data Speed (Baud Rate) ....................................................................... 33 RPCI/DIU Default Communication Parameters .................................................... 33 Index ..............................................................................................................................37
Strata DK PC/Data Interface 5/99iii Introduction This guide provides instructions for the use of the Strata DK Personal Computer (RCPI-DI) and Data Interface Unit (PDIU-DS) features for the Strata DK systems. These systems include: ©DK14 ©DK16e/16 ©DK40i/DK40 ©DK424/DK280 (Release 3.0 or higher) All the features in this guide have practical applications for diverse office environments. Instructions are provided on how to use the RCPIs and DIUs to connect Personal Computers (PCs) together to exchange files, to share a printer or a modem, to access a mainframe, and more. This user guide is not needed to use a TAPI software application. See the user guide for the software application program being used.
Introduction Organization ivStrata DK PC/Data Interface 5/99 Organization This user guide is divided as follows: ©Chapter 1 – The Grand Tour provides an overview of DIU hardware: their function, controls, and applicable indicators. ©Chapter 2 – User Instructions provides descriptions and instructions for each type of voice and data transmission made from the DIUs. ©Chapter 3 – Mode Definitions contains information on various advanced communication modes.
Introduction Conventions Strata DK PC/Data Interface 5/99v Conventions NoteElaborates specific items or references other information. Important!Calls attention to important instructions or information. Letters in [brackets] represent buttons which have Directory Numbers on them. For example: NoteThroughout this guide, RPCI-DI-equipped digital telephones that are connected to ASCII terminals or PCs are referred to as data telephones. [PDN] represents a Primary Directory Number (also known as an Extension Number for your telephone). [SDN] represents a Secondary appearance of a [PDN]. A [PDN] which appears on another telephone is considered an [SDN]. [PhDN] represents a Phantom Directory Number button (an additional Directory Number). [DN] represents a Directory Number button (also known as an Extension or Intercom Number). Whenever [DN] is used in this guide, it means the user can use any [PDN], [SDN], or [PhDN]. [DSS] represents the directory number of another station which is accessed from a DADM or DSS Console when this button is pressed. ([WUDEROG represents buttons on a telephone. ~means “through” + is used for multiple key entries. ä denotes the step in a one-step procedure. represents text that appears on a PC or terminal screen. ATDDYYY CONNECTXXXX
Introduction Mnemonics viStrata DK PC/Data Interface 5/99 Mnemonics Mnemonics appearing in this user guide are defined below: BPSBits Per Second DIUData Interface Unit LCDLiquid Crystal Display LEDLight Emitting Diode PCPersonal Computer DPIU-DSStand-alone Data Interface Unit RPCI-DIPersonal Computer/Data Interface Unit Related Documents The following user guides are available for Strata DK telephones: ©Strata DK Digital Telephone User Guide, which includes instructions for LCD Telephones, Add-on Modules, and Digital Direct Station Selection (DDSS) Consoles. ©Strata DK Installation and Maintenance Manual provides installation instructions and requirements for RPCI-DIs and Data Interface Units connecting to a Strata DK system. See the chapter on Peripherals. ©Strata DK Programming Manual provides programming instructions and record sheets for RPCI-DIs and Data Interface Units.
Strata DK PC/Data Interface 5/991 The Grand Tour1 Toshiba provides two interface units that integrate the Strata DK telephone system with PCs, printers, and modems for a variety of applications. The Stand-alone Data Interface Units (PDIU-DS) normally connects to printers and modems so that they can be shared by all users via data calls through the DK telephone system. The telephone PC Interface Unit (RPCI-DI) is built into the base of the digital telephone and connects to the COM port of a PC. There are two operating modes: ©Telephone Application Program Interface (TAPI) mode ©Data communication mode The PC TAPI software program automatically controls the operation mode (TAPI or Data Communications) of the RPCI. A 2B+D ISDN-type digital link in conjunction with the RCPIs and DIUs enable digital telephones to participate in simultaneous voice and data calls. Voice and data calls are transmitted over the same digital telephone wire pair. This offers you several calling options. For example, a digital telephone user can place a voice call while in the middle of a data call to a printer or host computer, etc. This chapter lists all the equipment required to originate or receive a data call. In addition, it explains the function and configuration of the Data Interface Units (DIUs), both the RPCI-DI and PDIU-DS types.
The Grand Tour Hardware Requirements 2Strata DK PC/Data Interface 5/99 Hardware Requirements The following hardware is required to originate a data call: ©A RPCI-DI (replaces digital telephone base) ©A PC or ASCII Terminal ©One of the following Toshiba 2000- or 1000-Series Digital Telephones: ©DKT2010-H (10-button model) ©DKT2010-SD (10-button model with a LCD and speakerphone) ©DKT2020-S (20-button model) ©DKT2020-SD (10-button model equipped with LCD and speakerphone) ©DKT1010-H (10-button model) ©DKT1020-SD (10-button model equipped with LCD and speakerphone) A data call can be made to a device connected to a DIU (RPCI-DI or PDIU-DS), such as mainframe computers, printers, modems, PCs, and ASCII terminals. Integrated Data Interface Unit (RPCI-DI) A telephone within the Strata DK system that participates in a data call must be a Toshiba digital telephone equipped with an integrated DIU (RPCI-DI). A label reading “MODEL RPCI-DI” on the bottom of the telephone and an RS-232 connector on the back of the telephone both indicate that a telephone is equipped with a RPCI- DI. See Figure 1. NoteThroughout this guide, RPCI-DI-equipped digital telephones that are connected to ASCII terminals or PCs are referred to as data telephones.