Home
>
Toshiba
>
Telephone
>
Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual
Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual
Here you can view all the pages of manual Toshiba Perception E Ex Digital Pbx Installation And Maintenance Manual. The Toshiba manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 341
AlTACHMENT A Tl/DS-1 INTERFACE The DS-1 interface operates at the rate of 1.544 Mbps. This rate is obtained by either one of the following two methods: METHOD 1: l Rate of each channel (time slot) = 64 kbps l 64 kbps * 24 channels = 1.536 Mbps l Rate required for synchronization = 8 kbps l DS-1 rate = 1.536 Mbps + 8 kbps = 1.544 Mbps METHOD 2: l 8 bits per channel * 24 channels = 192 bits l 1 bit for frame synchronization l Total bits in one frame = 193 bits l DS-1 rate = 193 bits * 8000...
Page 342
PERCEPTIONea,, Tl/DS-1 SEPTEMBER 1991 frames within the Super-frame. l The identification is done by verifying the Terminal Framing (FT) bit sequence “101010” (odd frames) and the Signaling Framing (FS) bit sequence “001110” (even frames). (See Figure 2.) 2) Twenty-four frames per Super-frame. This grouping is known as the Extended Super- frame (ESF). l In this arrangement the framing bit is time multiplexed to support three functions, namely, Synchronization, Cyclic Redun- dancy Check...
Page 343
PERCEPTIONeb,, Tl/DS-1 SEPTEMBER1991 tion imposes that in every frame of 8(n+l) bits, where n = 1 - 23, there must be at least an “n” number of “ONE.” There can also be no more than 15 consecutive “ZEROS” present. To comply with these requirements, the Tl/DS-1 interface pro- vides the following two techniques: 1) Zero Code Suppression (ZCS): This tech- nique forces the second least significant bit of any time slot with eight consecutive “ZEROS” to “ONE.” 2) Bipolar Eight Zero Substitution...
Page 344
PERCEPTIONeb,, Tl/DS-1 SEPTEMBER 1991 Loss of Signal (LOS) A Loss of Signal (LOS) condition is specified when the DS-1 signal is absent for more than 150 milli- seconds. Upon detection of LOS, the DS-1 inter- face generates a consecutive sequence of unfra- med all “ONE”signal, in orderto keep the regenera- tive repeaters alive. This condition causes the FALM LED to light. Jitter Jitters are short-term variations of significant in- stants (of a digital signal) from their idle positions in...
Page 345
PERCEPTIONeh, SYSTEM RECORD FEBRUARY 1992 Pdwceptionk 6; ex APPENDIX #I SYSTEM RECORD Version D.05
Page 347
PERCEPTIONeh, SYSTEM RECORD FEBRUARY 1992 SYSTEM DATA BLOCK 2 (DSD2 Program) *Enter the name and access code in this column.
Page 348
PERCEPTIONeh,, SYSTEM RECORD FEBRUARY 1992 CLASS OF SERVICE DATA BLOCK (DCOS Program) NOTE: Use multiple lines as required. AlTENDANT DATA BLOCK (DATT Program) ITEM Attendant Number PROMPT REQ AN0 ENTRY Al-l-0 ATT1 0 1 NOTE: Use a second sheet if Tenant Service is activated. -3-
Page 349
PERCEPTIONeh, SYSTEM RECORD FEBRUARY 1992 ELECTRONIC/DIGITAL TELEPHONE BLOCK (DEKT Program) PCB Location (L 1 PROMPT ENTRY ENTRY ENTRY ENTRY ENTRY ENTRY ENTRY ENTRY ’ _- d , I”U , I I I I I I I MT A I\T t N Button Acsinnmnnts- ““Syy . . I l”. ..“. DN Onlv! KEY 0 1 I I I I I I I Primary , t 1 KEY 1 KEY 2 _--__ ^ KEY 4 KEY 5 KEY 6 KEY 7 KRV 8 I -_-- - 1 KEY 9 1 KEY 10 KEY 11 KEY 12 NOTE: Use multiple sheets as required, Sheet / of 9 -4-
Page 350
STANDARD TELEPHONE DATA BLC ITEM 1 PROMPT Port Number Directory Number Station Set Mix Class of Service Tenant Number Call Pickup Group Hunt Number REQ POR DN SMX cos TEN PUG HNT Dialing Type Speed Dial List Warning Tone Allowed? Call Forward to Trunk Toll Restriction Class DLG SDL WTA CFT TOL Off-hook Call Messaae Waitina Lamo I I Announce Emeraencv Rinadown Station I I I MWL i RDS OCA PERCEPTION,~, SYSTEM RECORD FEBRUARY 1992 CK (DSlT Program) PCB Location (1...