INSTALLING OPTIONAL EQUIPMENT -------------------------------- Audio Source Audio outputI Shielded Cable M C B M C B B-LBR-A Box Amp Enable (If required) FIGURE 2-11 USING THE B-LBR-A PCB TO CONTROL AN AUDIO LOUD BELL 2-29
INSTALLING OPTIONAL EQUIPMENT Installing MusicThis section provides information on installing Background Music in the BUSINESSCOM PLUS System. Specifications BGM (all systems) Input Impedance: 600 ohms Input Level: Nominal 250 Maximum Input: 1 Vrms BGM Installation, BUSINESSCOM PLUS Refer to Figure 2-12 Installation of Background Music,BUSINESSCOM PLUS 1. Connect BGM source inputs to clips of the Block.(If BGM source is also used as a source for MOH,cross connect clips to clips 45, 46, respectively. 2. Adjust BGM level with VR2, on the PCB. 3. Program required information in Programs 18 and 26. Block To Power Failure Line To Power Failure Line 2 To Power Failure Line 3 To Door Chime Box 1 To Door Chime Box 2 To BGM Source MOH External Source Amplifier-External Speaker External Paging Contacts FIGURE 2-12 INSTALLATION OF BACKGROUND MUSIC, BUSINESSCOM PLUS 2-30
INSTALLING OPTIONAL EQUIPMENT BGM Installation, BUSINESSCOM PLUS Refer to Figure 2-13 Installation of Background Music,BUSINESSCOM PLUS 1. Connect inputs from BGM source to clips of the Block. If the BGM source is not used as a source for MOH,proceed to step 3. 2. If BGM source is also used as a source for MOH: a.Overlap approximately four inches of wire, and punch down the wire approximately four inches from the end. Punch down overlap from wire connected at clip 21 to clip 9. C.Punch down overlap from wire connected at clip 22 to clip 10. 3. Adjust the BGM level with on the B-HBU-A PCB. 4. Program required information in Program 26. WHT-BLU Block 4 BLU-WHT WHT-ORN To DSS 2 To Door Chime Box 1 To Door Chime Box 2 To External MOH Source To MOH Contacts To External Zone 1 To External Zone 1 Contacts To External Zone 2 To External Zone 2 Contacts , To Alarm Input 1 FIGURE 2-13 INSTALLATION OF BACKGROUND MUSIC, BUSINESSCOM PLUS 2-31
INSTALLING OPTIONAL EQUIPMENT Installing External Music On Hold External MOH An external music source can serve as a substitute for the internally-synthesized MOH that is available. Specifications BGM (all Impedance: 600 ohms Input Level: Nominal 250 Maximum Input: 1 Vrms MOH Installation, BUSINESSCOM PLUS Refer to Figure 2-14Installation of External Source of Music On Hold,BUSINESSCOM PLUS 1. Connect inputs from an external MOH source to clips on the Block. 2. Move switch 2 on the PCB in the KSU to opposite the 2 designation. Use SW1 on switch 2 to select either internal MOH or external MOH. 3. Adjust the MOH level with VRO on the PCB. To BGM Source MOH External Source ,Amplifier-External External Contacts Block FIGURE 2-14 INSTALLATION OF EXTERNAL SOURCE OF MUSIC ON HOLD, BUSINESSCOM PLUS 2-32
INSTALLING OPTIONAL EQUIPMENT MOH Installation, BUSINESSCOM PLUS Refer to Figure 2-15Installation of External Source of Music On Hold in a BUSINESSCOM PLUS 1. Connect inputs from external MOH to clip on the Block. 2. To select external MOH, move SW1 on the B-TSU-A PCB to the opposite position of that marked 1. (The 1 position is used to select internal MOH.) 3. Adjust the audio level of MOH with on the B-TSU-A PCB. Block WHT-BLU To DSS To Door Chime Box To External MOH Source 2-15INSTALLATION OF EXTERNAL SOURCE OF MUSIC ON HOLD, BUSINESSCOM PLUS 2-33
INSTALLING OPTIONAL EQUIPMENT Installing Music On Hold Contacts MOH Contacts, BUSINESSCOM PLUS This section provides information on installing an external device to MOH Contacts. The B-HBU-A PCB has an auxiliary relay for MOH that is energized when a call is placed on Hold. The energized relay provides a closure for control of an audio source. Specifications MOH Contacts Current Rating: 1.25 amps for 24 VDC resistive loads Installation Refer to Figure 2-16 Music On Hold Contacts Wiring: 1. Connect wires to clips on the Block. 2. Connect the other ends of the wires to the device. Block To DSS 1 To DSS 2 To Door Chime Box 1 To Door Chime Box 2 To External MOH Source BLU-RE To External To External To ExternalZone Zone Zone Contacts Contacts FIGURE 2-16 MUSIC ON HOLD CONTACTS WIRING 2-34
INSTALLING OPTIONAL EQUIPMENT Installing Paging Equipment External Paging ContactsExternal zones have normally open contacts. If a zone is activated,the contacts close. When a zone receives BGM,the contacts become continually closed. The relays for each zone are energized when Paging amplifiers are in use,including CO audible and BGM (if programmed).The relay is on the PCB in the BUSINESSCOM PLUS The relays are on the B-GCU-A PCB,a daughter board on the tone sender PCB (B-TSU-A) in the BUSINESSCOM PLUS SpecificationsCurrent Rating:1.25 amps for 24 VDC resistive loads Installation, BUSINESSCOM PLUS Refer to Figure 2-17External Paging Contacts Wiring on a BUSINESSCOM PLUS 1. Connect wires to clips on the Block. 2. Connect the other ends of the wires to the device. ORN-YEL To Power Failure 1 To Power Failure Line 2 To Power Failure 3 To Door Chime Box 1 To Door Box 2 To BGM Source MOH External Source Speaker External Paging Contacts Block FIGURE 2-17 EXTERNAL PAGING CONTACTS WIRING, BUSINESSCOM PLUS 2-35
INSTALLING OPTIONAL EQUIPMENT Installation BUSINESSCOM Refer to Figure 2-18External Paging Contact Wiring, BUSINESSCOM PLUS 1. Connect wires to clips on the Block for the first set of External Paging Contacts 2. Connect the other ends to the device. 3. Connect wires to clips on the Block for the second set of External Paging Contacts, and connect the other ends to the device. Block To ToDSS 1 DSS 2 To To ToDoor Chime Box 1 Door Chime Box 2 External MOH Source ToMOH Contacts To External Zone 1 To External Zone 1 Contacts To External Zone 2 To To To To External Zone 2 Contacts BGM Source Alarm Input 1 Alarm Input 2 FIGURE 2-18 EXTERNAL PAGING CONTACTS WIRING, BUSINESSCOM PLUS 2-36
INSTALLING OPTIONAL EQUIPMENT Installing External Paging Output This section provides information on the installation of external devices to the external zone(s). Each zone can receive CO Audible,BGM, External Alarm Signals, and Paging.Speakers can be used to broadcast these signals at the zone.External page zones can be used to provide talk-back paging. SpecificationsOutput Impedance: 600 ohms Output Level: Nominal 250 Maximum Output:400 RMS Installation of External Devices, BUSINESSCOM PLUS Refer to Figure 2-19External Paging Output Wiring, BUSINESSCOM PLUS 1. Connect wires from clips on the Block to an amplifier.The amplifier inputs must match the above specifications.Attach the speaker to the amplifier. 2. Program required information in Programs 2, 18, 26, and 28. 3. Adjust the zone volume level with on the PCB. T o Power Failure Line 1 To Power Failure Line 2 ToPower Failure Line 3 ToDoor Chime Box 1 MOH External Source External Paging Output 1External Paging Contacts Block FIGURE EXTERNAL PAGING OUTPUT WIRING, BUSINESSCOM PLUS 2-37
INSTALLING OPTIONAL EQUIPMENT Installation of External Devices, BUSINESSCOM PLUS Refer to Figure 2-20,External Paging Output Wiring on a BUSINESSCOM PLUS 1. Connect wires from clips on the Block to an amplifier for External Zone 1. The amplifier inputs must match the specifications above. Attach the speaker to your amplifier. 2. Connect wires from clips on the Block to an amplifier for External Zone 2. The amplifier inputs must match specifications above. Attach the speaker to your amplifier. 3. Program the necessary information on Programs 2, 26, and 28. 4. Adjust the volume level of External Zone 1 with on the B-GCU-A PCB. 5. Adjust the volume level of External Zone 2 with VR2 on the B-GCU-A PCB. Block To Door Chime Box To Door Chime Box To External MOH S To MOH Contacts To External Zone To External Zone 1 To External Zone To External Zone 2 To BGM Source To Alarm Input 1 : 1 1 Contacts 2 Contacts FIGURE 2-20 EXTERNAL PAGING OUTPUT WIRING, BUSINESSCOM PLUS 2-38