    							COMPLETING THE EQUIPMENT LIST
    This section provides instructions for completing the
    Equipment List (Table  located at the end of this
    part.Use the Equipment List to make a record of the
    required equipment.
    Item 1 
     Major Components
    KSU
    Each BUSINESSCOM PLUS System requires a KSU and a
    power supply 
    two major components of every 
    NESSCOM PLUS  System.
    The KSU is the cabinet containing the printed circuit
    boards  necessary to operate the system. The
    following types of 
     are available for the
    BUSINESSCOM PLUS 
     Systems:
    o The BUSINESSCOM 
     KSU (P/N 15000 or P/N 15001)
    for the BUSINESSCOM PLUS 
     System, shown in
    Figure l-l,includes one of each of the following
    0
    0
    0
    o The BUSINESSCOM 24 KSU-B (P/N 15101)
    which can be used instead of the BUSINESSCOM 24
    KSU (P/N 
     described below.
    o The BUSINESSCOM 36 KSU-B (P/N 15201)
    for the BUSINESSCOM PLUS 
     which can be
    used instead of the BUSINESSCOM 36 KSU (P/N 15200)
    described below.
    o The BUSINESSCOM 64 EXP-CAB (P/N 15301)
    is the expansion cabinet which increases the
    capacity of the BUSINESSCOM 36 KSU-B (P/N 15201)
    to 24 lines and 64 stations. It uses a 
     to
     power cable.
    o The BUSINESSCOM 24 KSU (P/N 15100)
    for the BUSINESSCOM PLUS 24 accommodates 12
    lines and 24 stations. The base cabinet is
    identical to the BUSINESSCOM 36 KSU (P/N 15200)
    except that it can support fewer lines and stations. 
    The KSU includes the power supply cable used to 
    connect the KSU to the  Supply.
    l-2 
    						
    							COMPLETING THE EQUIPMENT LIST
    KSU 
    0The BUSINESSCOM 36 KSU (P/N 15200)
    for the BUSINESSCOM PLUS 36 System accommodates
    12 lines and 36 stations.The KSU includes the
    power supply cable used to connect the KSU to
    the 
     Supply.
    o The BUSINESSCOM 64 KSU (P/N 
    for the BUSINESSCOM PLUS 64 System accommodates
    24 lines and 64 stations. The KSU includes a short
    18-pin-to-18-pin power supply cable used to connect
    the KSU to the 
     Supply.
    On the Equipment List (Table 
     indicate the KSU
    for your system.
    l-3 
    						
    							COMPLETING THE EQUIPMENT LIST
     
    Power
    OFF ON. . . . . .
    FIGURE l-l THE BUSINESSCOM PLUS KSU AND POWER SUPPLY
    l-4 
    						
    							COMPLETING THE EQUIPMENT LIST
    Item 1  Major Components 
    Power Supply
    The following power supplies are available for
    BUSINESSCOM PLUS Systems:
    Battery
    Backup Power
    SystemCondition Supply
    P/N
    BUSINESSCOM PLUS 
    without62505 or
    15420
    BUSINESSCOM PLUS 
    without15120
    BUSINESSCOM PLUS 
    with
    BUSINESSCOM PLUS 64without15320
    BUSINESSCOM PLUS 64with
    15320H
    or 
    Power Supply
    CordsThe following power supply cords are also available:
    P/N
    15101 or 15201
    15301
    15100 or 15200
    15300
       P. 
    (18-pin)
    10821 10822
    N/A 10822
    15121
    15141
    N/A 15321
    On the EquipmentList,indicate the power supply for
    your BUSINESSCOMPLUS System.
      
    						
    							COMPLETING THE  LIST
    Item   Printed Circuit Boards
    The 
     installed in the KSU are as follows:
     FOR THE BUSINESSCOM PLUS 
    The following  control the operation of a
    BUSINESSCOM PLUS 
    Main Processing
    Unit and Station  PCB
    The  PCB (P/N 15060) is the central
    processor and eight key station interface PCB which
    is included in the P/N 15000 KSU. It provides 
    control and contains:
    0System Main Processor Unit 
    0System  memory: one 8K x 8 RAM
    0An OPX-enable strap (JO)
    0A power-on reset circuit to restart the MPU
    0One memory backup battery *
    0Various timers for program control
    0Three power  and  a   clock generation
    confirmation LED
    0400 Hz interrupted tone for Paging splash tones,
    Intercom dial tone, Intercom busy tone, and
    Intercom fast-busy tone
    0800 Hz tone for splash tones and alarm tones
    0Two tune internal Music On Hold 
    0A switch to select between internal MOH and
    external MOH
    0External Background Music  input
    0External MOH relay contact
    0External Zone Paging output and relay contacts
    0Two Internal Zone Paging amps, one for each
    Intercom port.Paging is selected by the MPU and
    the crosspoints for each station.
    0Interface circuits for eight key telephones and
    crosspoint matrix for five lines, two Intercom
    ports,and two page amplifiers
    0Outputs for three power failure bells for lines 1,
    2 and 3
    0Three adjustment potentiometers: VR-0 MOH adjust,
    VR-1 page zone output adjust, BR-2 BGM adjust
    050-pin connector  for installer connections
    The 
     PCB is compatible with daughter boards
     and  PCB.
     
    l-6 
    						
    							COMPLETING THE EQUIPMENT LIST
    ----------------------------------------------------------------------
    Item 2 Printed Circuit Boards 
     FOR THE BUSINESSCOM PLUS  
    Main Processing
    Unit PCB
    ROM PCB
    ROM PCB
    ROM PCB
    Three-Circuit
    Line 
    The  PCB (P/N 15061) is similar to the 
     PCB in system memory,but it has a 
    PCB daughter board installed. The  PCB is
    included in the P/N 15001 KSU.
    The 
     PCB (P/N 150701, which is included in
    the P/N 15000 KSU, is a daughter board compatible
    with the 
     PCB that provides three 16K x 8 ROM
    for the basic system-operating software.
    The 
     PCB (P/N  is a daughter board
    compatible with the 
     PCB that provides three
    16K 
    x 8 ROM, one 4K x 8 ROM, and one 2K x 8 ROM. This
    memory is used for the basic system-operating software
    and for Station Message Detail Recording 
    The  PCB (P/N 150711, which is included in
    the P/N 15001 KSU, is a daughter board compatible
    with the 
     PCB. I t  provides three 16K x 8
    ROMs and one 
     x 8 RAM.This memory is used for the
    basic system-operating software and for SMDR.
    Note that the optional SMDR Interface PCB, B-SMDR-SA,
    requires the 
     or the  PCB.
    The 
     PCB (P/N  is a CO/PBX/DIAL-IN
    interface included in either 
     KSU, and it
    provides:
    0Interface circuits for three  lines. Each of
    the interface circuits contains a ring detect
    circuit,a seize detect circuit, an electronic
    dial pulse circuit,
    a muting relay for dial pulse
    signaling and a negative impedance circuit to
    compensate for losses on the line
    0One DTMF generator
    0Crosspoints for MOH
    0Six l-amp fuses for tip and ring power cross
    protection
    0Nine Metal Oxide Varistors  for secondary
    lightning protection
    0LED for in-use indication
    0Six straps for Power Failure Cut-Through operation
    l-7 
    						
    							COMPLETING THE EQUIPMENT LIST
    Item  Printed Circuit Boards 
    BUSINESSCOM  FOR THE BUSINKSSCOM PLUS  
    Two-Line CO PCB
    The  PCB (P/N 15020) is similar to the
     PCB,but it incorporates only:
    0Two interface circuits for  lines
    0Four l-amp fuses for tip and ring power cross
    protection
    0Six  for secondary lightning protection
    0Four straps for Power Failure Cut-Through
    operation
    0All other functions of the  PCB
    Four-station
    Interface PCB
    The B-QSTU-A PCB (P/N 15025) is a station interface
    which provides:
    0Interface for four key telephones
    0Crosspoint matrix for five lines, two Intercom
    ports, BGM,and two page ports
    0Output for external zone paging amplifier
    0Two Power Failure External Bell outputs for line 4
    and line 5
    0 connector  for installer connections
    1-8 
    						
    							COMPLETING THE EQUIPMENT LIST
    Item 2 
    Printed Circuit Boards 
     FOR THE  PLUS  
    Two Key Telephone,
    Two Single Line OPX
    Interface PCB
    The  PCB (P/N  is a station interface
    between the KSU and single line telephones. It
    provides:
    0Interface circuits for two key telephones and two
    single line Off-Premises Extension 
    telephones*
    0An OPX circuit that can be assigned by programming
    as a dial-in station for Direct Inward System
    Access 
    0Crosspoint matrix for five CO lines, BGM, two
    Intercom links,and two page ports
    0Six option straps for OPX/DISA and internal or
    external battery
    0Six  for secondary lightning protection
    0Control of the ringing signal provided by an
    external ringing generator to the OPX
    The 
     PCB is required for OPX and DISA. The
     PCB can be used with either DTMF or dial
    pulse type telephones,but DISA lines must be served
    by a DTMF instrument.
    A single line telephone installed using an
    interface PCB (e.g.,the 
     or the B-STU-D
     will be referred to as an Off-Premises
    Extension 
    Single line telephones may be
    installed on-premises or as 
    Multi-Frequency
    Receiver Unit PCB
    The B-MFRU-B PCB (P/N  is a DTMF receiver
    daughter board for the 
     or the B-STU-D PCB.
    The B-MFRU-B provides interface circuits to detect
    and decode DTMF signals from DTMF 
     and DISA
    calls.
    One B-MFRU-B PCB is required to accept DTMF from each
    single line (2500 type) telephone or DISA port.
    Door Chime Box
    Interface PCB
    The  PCB (P/N 15045) is used with Door Chime
    Box (P/N 
     It provides:
    0Interface circuits for two Door Chime Boxes
    0VR-1 to adjust the audio volume level to the Door
    Chime 
    l-9 
    						
    							COMPLETING THE EQUIPMENT LIST
    Item 
      Printed Circuit Boards 
     FOR THE  PLUS  
    SMDR
    Interface PCB
    (B-SMDR-SA)SMDR on a BUSINESSCOM PLUS 
     requires the following
    equipment:
    0Installation of the B-SMDR-SA PCB (P/N 15075)
    0The correct B-5ROU PCB:
    0 for systems with a  PCB
    0 for systems with a  PCB
    0A customer-provided RS-232-C compatible serial
    printer configured  as follows:
    0ASCII format
    01 start bit, 7 data bits, no parity, and
    1 stop bit
     FOR THE BUSINESSCOM PLUS 
    Main processing
    Unit PCB
    The
    0
    0
    B-MPU-A PCB (P/N 15165) contains:
    The System Main Processing Unit
    System memory:three 16K x 8 ROMs
    two 8K x 8 
    Sixteen station-enable leads
    One write-protect circuit
    Six line-enable  leads
    Two expansion leads
    One 16  Hz generator
    One power-on reset circuit to restart MPU
    Battery for memory backup *
    Several timers
    One LED for confirmation of clock generation
    A 3V non-rechargeable, replaceable lithium
    battery,installed for power failure memory
    backup,supports memory for 
     one
    month after  a  power failure.
    Main Processing
    Unit PCB
    (B-MPU-B)The B-MPU-B PCB (P/N 15166) is similar to the B-MPU-A
    PCB except that it provides three 16K x 8 ROMs, one 8K
    x 8 ROM,and three 8K x 8 
     of memory for the basic
    system-operating software and SMDR.
    The B-MPU-B PCB is compatible with the B-SMDR-LA PCB.
    l-10 
    						
    							COMPLETING  EQUIPMENT LIST
    Item 2 Printed Circuit Boards 
     FOR THE BUSINESSCOM PLUS  
    Main Processing
    Unit PCB
    The  B-MPU-C PCB (P/N 15167) is similar to the B-MPU-A
    PCB except that it provides two 32K x  8 ROMs and three
     x 8  of memory for the basic system-operating
    software and for SMDR. It also:
    0Provides Enhancement Software Package 
    features
    0Is compatible with the Busy Lamp Field 
    telephone
    Like the B-MPU-B,
    the B-MPU-C PCB is compatible with
    B-SMDR-LA PCB.
    Tone Sender PCB
    (B-TSU-A) T h e
    0
    0
    0
    0
    0
    0
    0
    0
    ..0
    Four-Station
    Interface PCB
    (B-STU-A) T h e
    0
    0
    Two-Station
    Interface PCB
    (B-STU-B) T h eB-TSU-A PCB (P/N 15155) provides the following:
    Paging splash tones and DSS preemption tones
    Intercom busy tone
    Intercom fast busy tone
    Splash and alarm tones
    Internal MOH generator
    Switch SW1 to select between internal and external
    MOH
    Volume control potentiometer to adjust the level on
    internal or external  MOH
    Six internal zone paging amplifiers, one for each
    port
    A daughter board for external Music On Hold, BGM
    Interface 
     and External Page Interface
    PCB 
    B-STU-A PCB (P/N 15125) provides:
    Interface for four key telephones
    Crosspoint matrix for 12 lines, six Intercom
    ports,and six page ports
    B-STU-B PCB (P/N 15135) is similar to the B-STU-A
    PCB,but it provides an interface in the first two
    ports only for up to two key telephones. 
    						
    All TiE manuals Comments (0)

    Related Manuals for TiE Businesscom Plus Hardware Manual