TiE Businesscom Plus 24/36/64 Installation Manual
Have a look at the manual TiE Businesscom Plus 24/36/64 Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 13 TiE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Speakerphones 2.16Speakerphones, which can be installed in Standard telephones, permit handsfree CO conversations. The maximum number of speakerphones permitted in each system is as follows: 5.FCC AND TELCO REQUIREMENTS SystemMaximum 2412 3612 6424 5.01 Rules and regulations for the operation and installation of telephone equipment have been established by the Federal Communications Commission (FCC). According to Part 68, “Connection of Terminal Equipment to the Telephone Network” and its amendments, several actions are required before and during the installation of customer-provided telephone equipment. These actions are listed and described in the following paragraphs. 3.SPECIFICATIONSNOTIFICATION TO TELCO 3.01Refer to Tables l-2 and 1-3 for technical specifications pertaining to the Businesscom Plus 24 systems. 4.SITE REQUIREMENTS 5.02 As owner of this telephone system, you must give the following information to the operating telephone company (telco) before connecting or disconnecting it: (1) Sufficient notice of your intention to use privately owned telephone equipment. 4.01 The KSU should be installed in a clean, dry, secure location that prevents access by unauthorized personnel. This location, as detailed in Section 5, should comply with Bell Functional Product Class Criteria of September 1978, in publication PUB 48002 as stated in 3.4.3.2, paragraph C-Indoors With Environmental Control. The room must have adequate ventilation and have a temperature range that does not exceed 32 to 113 degrees F (0 to 45 degrees C) with a 10 to 95% noncondensing, relative humidity. The particular lines to be used (telephone numbers xxx-xxxx through xxx-xxxx). (3) Model: Businesscom Plus FCC Registration Number: Ringer Equivalence: Registered Jack: NOTE: Have telco drop the connectors within 25 feet of the installation. INCIDENCE OF HARM 4.02The installation site should provide ample room to mount the KSU on the wall along with the necessary5.03If customer-provided equipment is causing harm to the telephone network, the telephone company connecting blocks and any ancillary equipment. The installation site should not be located in areas subject to static electricity (e.g., dry copiers), vibration (e.g., heavy machinery), or in areas likely to be (e.g., basement level). 4.03The customer must provide a dedicated NEMA outlet with a and a 15 Ampmust, whenever practical, notify the customer that service may be temporarily discontinued. The company must also attempt to inform the customer before actually disconnecting service. The telephone company must provide customers with an opportunity to correct the problem and must advise customers of their right to bring complaint procedures before the FCC. circuit. A separate earth ground is required in addition to the third-wire ground on the AC circuit. If a music source or optional external paging equipment is installed, it must be connected to an AC circuit other than the system’s dedicated AC line. ONLY THE POWER SUPPLY SHOULD BE CONNECTED TO THE DEDICATED AC OUTLET.
Table SPECIFICATIONS, PLUS 24 GENERAL SPECIFICATIONS System Capacity:MAX. NO.System Capacity:MAX. NO.CO Lines8Speakerphones12Intercom Talkpaths6OPX Telephones12 Key Telephones24 ELECTRICAL SPECIFICATIONS Power Requirements: (AC Supply Must Be Dedicated) KSU/Power Supply Operating Range: 117 VAC 10%60 Hz Hz Power Dissipation: Supply Unit: 340 Watts 2.9 Amp Grounding Requirements:1160 KSU Ground lug, 14 AWG or larger copper wire to cold water pipe or known good earth ground Cable Requirements: Four conductor (two-pair twisted) station wire. 1000 feet (304.8 m) using 24 AWG. 1500 feet (457.2 m) using 22 AWG. Door Chime Box: 500 feet (152.4 m) using 24 AWG. Console: 1000 feet (304.8 m) using 24 AWG or 500 feet (152.4 m) if two consoles are used and one is used as a BLF (Busy Lamp Field) Background Music Specifications: Input Impedance: 600 OHMS Input Level: Nominal 250 Maximum Input: 1 Volt RMSLimit for Alarm Circuit: Loop Resistance: 1000 OHMS Max. Music On Hold Specifications: External Paging Specifications: Input Impedance: 600 OHMS Output Impedance: 600 OHMS Input Level: Nominal 250 Output Level: Nominal 250 Maximum Input: 1 Volt RMS Maximum Output: 400 RMS MECHANICAL SPECIFICATIONS Dimensions and Weights: KSU: Power Supply: Executive/Key Telephone: Door Chime Box: DSS Console:16.8 in. x 21.5 in. x 7.8 in.26.5 Ibs. 430.0 mmx 550.0 mm x 200.0 mm12.0 kg 12.1 in. x 14.2 in. x 4.8 in.12.8 Ibs. 310.0 mmx 363.5 mm x 122.0 mm5.8 kg 3.1 in. x 8.0 in. x 8.6 in.2.2 80.0 mmx 205.0 mm x 221.0 mm1.0 kg 5.1 in. x 3.9 in. x 1.4 in.0.4 131.0 mmx 99.0 mm x 35.0 mm0.2 kg 2.0 in x 7.4 in. x 8.8 in.1.3 Ibs. 52.0 mmx 189.0 mm x 224.0 mm0.6 kg ENVIRONMENTAL SPECIFICATIONS Environmental Operating Conditions: Temperature: KSU and Telephones: 0 to 45 degrees C Door Chime Box: -20 to 60 degrees C Humidity: 10% to 95% noncondensing(32 to 113 degrees F) ( -4 to 140 degrees F)
Table 1-2SPECIFICATIONS, PLUS 36 GENERAL SPECIFICATIONS System Capacity:MAX. NO.System Capacity:MAX. NO.CO Lines12Speakerphones12 Intercom Talkpaths6OPX Telephones18 Stations 3 6 ELECTRICAL SPECIFICATIONS Power Requirements: (AC Supply Must Be Dedicated) Supply Operating Range: 117 VAC 10% Power Dissipation:60 Hz Hz Supply Unit: 480 Watts 4.1 Amps Grounding Requirements:1638 KSU Ground lug, 14 AWG or larger copper wire to cold water pipe or known good earth ground Cable Requirements: Four conductor (two-pair twisted) station wire. 1000 feet (304.8 m) using 24 AWG. 1500 feet (457.2 m) using 22 AWG. Door Chime Box: 500 feet (152.4 m) using 24 AWG. Console: 1000 feet (304.8 m) using 24 AWG or 500 feet (152.4 m) if two consoles are used and one IS used as a BLF (Busy Lamp Field) Background Music Specifications: Input Impedance: 600 OHMS Input Level: Nominal 250 Maximum Input: 1 Volt RMSLimit for Alarm Circuit: Loop Resistance: 1000 OHMS Max. Music On Hold Specifications:External Paging Specifications: Input Impedance: 600 OHMS Output Impedance: 600 OHMS Input Level: Nominal 250 Output Level: Nominal 250 Maximum Input: 1 Volt RMS Maximum Output: 400 RMS MECHANICAL SPECIFICATIONS Dimensions and Weights: KSU: Power Supply: Executive/Key Telephone: Door Chime Box: DSS Console:16.8 in. x 21.5 in. x 7.8 in.33.9 Ibs. 430.0 mm x 550.0 mm x 200.0 mm14.0 kg 12.1 in. x 14.2 in. x 4.8 in.12.8 Ibs. 310.0 mm x 363.5 mm x 122.0 mm5.8 kg 3.1 in. x 8.0 in. x 8.6 in.2.2 Ibs. 80.0 mmx 205.0 mm x 221.0 mm1.0 kg 5.1 in. x 3.9 in. x 1.4 in.0.4 Ibs. 131.0 mmx 99.0 mm x 35.0 mm0.2 k g 2.0 in. x 7.4 in. x 8.8 in.1.3 Ibs. 52.0 mm x 189.0 mmx 224.0 mm0.6 kg ENVIRONMENTAL SPECIFICATIONS Environmental Operating Conditions: Temperature: KSU and Telephones: 0 to 45 degrees C Door Chime Box: -20 to 60 degrees C Humidity: 10% to 95% noncondensing(32 to 113 degrees F) ( -4 to 140 degrees F)
Table H-3 SPECIFICATIONS, PLUS 64 GENERAL SPECIFICATIONS System Capacity:MAX. NO.CO Lines 2 4 Intercom Talkpaths 6Stations64 System Capacity: Speakerphones OPX TelephonesMAX. NO.24 32 ELECTRICAL SPECIFICATIONS Power Requirements: (AC Supply Must Be Dedicated) KSU/Power Supply Operating Range: 117 VAC 10% Power Dissipation: 60 Hz Hz Supply Unit: 870 Watts 7.4 Amps Grounding Requirements:2968 BTU/HI=. KSU Ground lug, 14 AWG or larger copper wire to cold water pipe or known good earth ground Cable Requirements: Four conductor (two-pair twisted) station wire. 1000 feet (304.8 m) using 24 AWG. 1500 feet (457.2m) using 22 AWG. Door Chime Box: 500 feet (152.4 m) using 24 AWG.Console: 1000 feet (304.8) using 24 AWG or 500 feet (152.4 m) if two consoles are used and one is used as a BLF (Busy Lamp Field) Background Music Specifications: Input Impedance: 600 OHMSInput Level: Nominal 250 Maximum Input: 1 Volt RMSLimit for Alarm Circuit: Loop Resistance: 1000 OHMS Max. Music On Hold Specifications: Input Impedance: 600 OHMS Input Level: Nominal 250 Maximum Input: 1 Volt RMS External Paging Specifications: Output Impedance: 600 OHMS Output Level: Nominal 250 Maximum Output: 400 RMS MECHANICAL SPECIFICATIONS Dimensions and Weights: KSU:27.8 in. x 26.1 in. x 8.5 in.81.6 Ibs.713.0 mm x 670.0 mm x 219.0 mm37.0 kg Power Supply:13.3 in. x 19.0 in. x 4.8 in.19.4 Ibs.340.0 mm x 488.5 mm x 122.0 mm8.8 kg Executive/Key Telephone:3.1 in. x 8.0 in. x 8.6 in.2.2 Ibs. 80.0 mm x 205.0 mm x 221.0 mm1.0 kg Door Chime Box:5.1 in. x 3.9 in. x 1.4 in.0.4 Ibs.131 .O mm x 99.0 mm x 35.0 mm0.2 kg DSS Console: 2.0 in.x 7.4 in. x 8.8 in.1.3 Ibs. 52.0 mm x 189.0 mm x 224.0 mm0.6 kg ENVIRONMENTAL SPECIFICATIONS Environmental Operating Conditions: Temperature: KSU and Telephones: 0 to 45 degrees C Door Chime Box: -20 to 60 degrees C Humidity: 10% to 95% noncondensing (32 to 113 degrees F) ( -4 to 140 degrees F)
BUSINESSCOM PLUS ELECTRONIC KEYTELEPHONESYSTEMS SECTION 2,FEWTURES CONTENTSPAGECONTENTSPAGE 1.INTRODUCTION..................... 2-2 2. DESCRIPTION...................... Automatic Intercom Answer........... Background Music (BGM)............. 2-2 Call Duration Timer................. 2-2 Call Forward With Follow-Me.......... Call Monitor....................... 2-3 Call Pickup....................... Call Announced.............. 2-4 Call Transfer Unannounced............ 2-4 Call Waiting....................... 2-4 Callback......................... Camp-On......................... 2-5 CO Lines.......................... 2-5 Common Use Line.................. Component Commonality............. 2-6 Conference, Add-On................. 2-6 Conference, Meet-Me................ Conference, Multi-Line............... 2-7 Conference, Unsupervised............. 2-7 Confirmation Tone.................. 2-8 Dial Pulse To Tone (DTMF) Conversion...................... Direct Inward System Access (DISA)..... 2-8 Direct Station Selection (DSS)......... Direct Station Selection (DSS) Console........................ Do Not Disturb ............... Do Not Disturb (DND) Override By DSS Console.................. Door Chime Box................... Dual Handsfree Hotline............ 2-10 Excluded System Features............ 2-11 Executive Call Forward.............. Executive Override (Barge In).........2-12 External Alarm Signals To Stations........................ 2-12 Flash........................... Flexible Line Appearance............ Flexible Station No. Assignment....... Group Hunt...................... Group Hunt ................2-14 Handsfree Reply On Intercom......... Hold............................2-15 Intercom........................ Last Number Dial.................. Line .................... Message Waiting...................2-16 Microphone On/Off................ Music On Hold .............. Night Class Of Service...............2-17 Night Transfer..................... Off-Premises Extension..............2-18 Paging, All Call....................2-19 Paging, All External Zone............2-19 Paging, External Zone...............2-19 Paging, Internal Zone............... Paging, Meet-Me.................. Private Line......................2-20 Recall Line Preference............... 2-21 Release Of Abandoned Calls ...................... Remote Busy Line Indication..........2-21 Ring .....................2-22 Ringing Line Preference.............2-22 Room Monitor.................... Save............................2-23 Single Step Access................. Speed Dial.......................2-23 Step Calling......................2-24 Tenant Service ....................2-24 Three Minute Warning Tone..........2-24 Toll Restriction....................2-25 Transfer Recall Display..............2-25
1.INTRODUCTION 1.01This section lists and details the features available in the Businesscorn Plus Both permanent and programmable features are discussed. This section should be used in conjunction with Section 4, SOFTWARE CONFIGURATION, when preparing the Program Record Form. 2.DESCRIPTION 2.01This section is formatted in the following manner: Description: discusses the basic elements of the feature. Conditions: lists and describes conditions that limit or enhance the feature under discussion. Basic Programming: lists required programming, i.e., programming necessary for feature operation. Programming: lists programs that limit or enhance feature operation. Feature Interactions: lists features that directly affect the feature under discussion. AUTOMATIC INTERCOM ANSWER Description: This feature permits single-step answer of an internal call. Conditions: None Basic Programming: None Related Programming: None Feature Interactions: Intercom BACKGROUND MUSIC (BGM) Description: This feature permits station speakers and external zones to receive Background Music. Conditions: (a) BGM is a customer supplied item. (b) BGM can serve as a source of Music On Hold. (c) BGM is interrupted at a zone and/or station by an incoming call, and at a station by an outgoing call. (d) BGM is interrupted at stations utilizing Room Monitor. (e) BGM utilizes one Intercom link. Basic Programming: Program 26-Background Music Related Programming: Program l&External Paging Output Feature Interactions: CO Lines Hold Intercom Music On Hold (MOH) Room Monitor CALL DURATION TIMER Description: This feature permits a user to time the duration of an outgoing CO call. Conditions: (a) This feature is available only on Executive Display telephones. (b) The timer starts from 0 to 255 seconds after CO line seizure depending upon programming. (c) This feature can be manually started. (d) If a Hold is implemented during a CO call, the timer is disabled and the display returns to its normal condition.
Basic Programming: Program Duration Timer Related Programming: Program Duration Start Timer Feature Interactions: CO Lines Hold CALL FORWARD FOLLOW-ME Description: This feature permits the automatic transfer of an incoming Intercom call to a second station (Call Forward). The destination of the forwarded call can be changed to yet a third station and so on (Follow-Me). Conditions: (a) The originating station can change the destination of the Call Forward. (b) Only the originating station can cancel a Call Forward. (c) The destination station can change the destination of the Follow-Me. (d) Program 49 (Excluded System Features) can disable this feature. (e) A call cannot be forwarded to a station that has invoked DND. (f) Executive Call Forward overrides Call Forward With Follow-Me. Basic Programming: None Related Programming: Program 49-Excluded System Features Feature Interactions: CO Lines Executive Call Forward Intercom CALL MONITOR Description: This feature permits the on-hook dialing of an Intercom or CO telephone number. Conditions: (a) Telephones without speakerphones must lift the handset to engage in a two-way conversation once the call is established. (b) The user can also monitor a CO call if placed on Hold. Basic Programming: None Related Programming: None Feature Interactions: CO Lines Intercom CALL PICKUP Description: This feature permits a station user to intercept an Intercom call intended for another station. Conditions: (a) Program 49 (Excluded System Features) can disable this feature. Basic Programming: None Related Programming: Program 49-Excluded System Features Feature Interactions: Intercom 2-3
CALL TRANSFER ANNOUNCED Description: Thisfeature permits the voice announced transfer of an established CO call. Voice Announce must be programmed. Program 49 (Excluded System Features) can disable this feature. If the transferred call is not answered within a programmed period of time, the call reverts back to the transferring station. This feature is accessible from a key telephone or DSS Console. Basic Programming: Program 24-Voice Announce /Tone Signal Call Related Programming: Program Console Port Assignment Program Transfer Timer Program 39-DSS Transfer Timer Program 49-Excluded System Features Feature Interactions: CO Lines Direct Station Selection (DSS) Console Intercom CALL TRANSFER UNANNOUNCED Description: This feature permits the transfer of an established CO call, with ringing, to a second station. Conditions: : (a) If the transferred call is not answered within a programmed period of time, the call reverts back to the transferring station. (b) Program 49 (Excluded System Features) can disable this feature. (c) This feature is accessible from a key telephone or a DSS Console. (d) Tone Signal must be programmed. Basic Programming: Program Announce /Signal Tone Call Related Programming: Program Console Port Assignment Program Timer Program 39-DSS Timer Program 49-Excluded System Features Feature Interactions: CO Lines Direct Station Selection (DSS) Console CALL WAITING Description: This feature permits two types of Call Waiting: (a) CO Call Waiting. Intercom Call Waiting. CO Call Waiting allows a station with a seized CO line to receive ringing for another incoming call on another line. Intercom Call Waiting allows a station with a seized Intercom link to receive ringing for another incoming Intercom call. Conditions: Intercom Call Waiting is unavailable at stations using Handsfree Reply On Intercom. ‘Iwo levels of Intercom Call Waiting are available through programming: (1) User-controlled: allows user to initiate the Call Waiting signal. (2) Automatic: the Call Waiting signal is automatically initiated. Callback and Camp-On are unavailable when the automatic mode of Intercom Call Waiting is in use. Call Waiting (CO) signals are blocked by all levels of Do Not Disturb when Do Not Disturb is in use. Intercom Call Waiting signals are blocked by Do Not Disturb (level 2 and level 3 where LED lights steadily) when Do Not Disturb is in use. This feature is permanent for Intercom calls with respect to the DSS Console, i.e., the DSS Console has permanent override capabilities. Basic Programming: Program 16-CO Call Waiting Program 23-Intercom Call Waiting Related Programming , Program Console Port Assignment