Home > TiE > Communications System > TiE Businesscom Plus 24/36/64 Installation Manual

TiE Businesscom Plus 24/36/64 Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual TiE Businesscom Plus 24/36/64 Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 13 TiE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							    Console 
    						
    							Speakerphones
    2.16Speakerphones, which can be installed in Standard
    telephones, permit handsfree CO conversations. The
    maximum number of speakerphones permitted in each
    system is as follows:
    5.FCC AND TELCO REQUIREMENTS
    SystemMaximum
    2412
    3612
    6424
    5.01 Rules and regulations for the operation and
    installation of telephone equipment have been
    established by the Federal Communications Commission
    (FCC). According to Part 68, “Connection of Terminal
    Equipment to the Telephone Network” and its amendments,
    several actions are required before and during the installation
    of customer-provided telephone equipment. These actions
    are listed and described in the following paragraphs.
    3.SPECIFICATIONSNOTIFICATION TO TELCO
    3.01Refer to Tables  l-2 and 1-3 for technical
    specifications pertaining to the Businesscom Plus
    24   systems.
    4.SITE REQUIREMENTS
    5.02 As owner of this telephone system, you must give the
    following information to the operating telephone
    company (telco) before connecting or disconnecting it:
    (1) Sufficient notice of your intention to use privately owned
    telephone equipment.
    4.01 The KSU should be installed in a clean, dry, secure
    location that prevents access by unauthorized
    personnel. This location, as detailed in Section 5, should
    comply with Bell Functional Product Class Criteria of
    September 1978, in publication PUB 48002 as stated in
    3.4.3.2, paragraph C-Indoors With Environmental Control.
    The room must have adequate ventilation and have a
    temperature range that does not exceed 32 to 113 degrees
    F (0 to 45 degrees C) with a 10 to 95% noncondensing,
    relative humidity.
     The particular lines to be used (telephone numbers
    xxx-xxxx through xxx-xxxx).
    (3) Model: Businesscom Plus 
    FCC Registration Number: 
    Ringer Equivalence: 
    Registered Jack: 
    NOTE: Have telco drop the  connectors within 25 feet
    of the installation.
    INCIDENCE OF HARM
    4.02The installation site should provide ample room to
    mount the KSU on the wall along with the necessary5.03If customer-provided equipment is causing harm to
    the telephone network, the telephone company
    connecting blocks and any ancillary equipment. The
    installation site should not be located in areas subject to static
    electricity (e.g., dry copiers), vibration (e.g., heavy
    machinery), or in areas likely to be  (e.g., basement
    level).
    4.03The customer must provide a dedicated NEMA
     outlet with a    and a 15 Ampmust, whenever practical, notify the customer that service
    may be temporarily discontinued. The 
     company
    must also attempt to inform the customer before actually
    disconnecting service. The telephone company must provide
    customers with an opportunity to correct the problem and
    must advise customers of their right to bring complaint
    procedures before the FCC.
    circuit. A separate earth ground is required in addition to the
    third-wire ground on the AC circuit. If a music source or
    optional external paging equipment is installed, it must be
    connected to an AC circuit other than the system’s dedicated
    AC line. ONLY THE POWER SUPPLY SHOULD BE
    CONNECTED TO THE DEDICATED AC OUTLET. 
    						
    							Table SPECIFICATIONS,  PLUS 24
    GENERAL SPECIFICATIONS
    System Capacity:MAX. NO.System Capacity:MAX. NO.CO Lines8Speakerphones12Intercom Talkpaths6OPX Telephones12
    Key Telephones24
    ELECTRICAL SPECIFICATIONS
    Power Requirements: (AC Supply Must Be Dedicated)
    KSU/Power Supply Operating Range: 117 VAC 
     10%60 Hz  Hz
    Power Dissipation:
     Supply Unit: 340 Watts  2.9 Amp
    Grounding Requirements:1160 
    KSU Ground lug, 14 AWG or larger copper wire to cold water pipe or known good earth ground
    Cable Requirements:
    Four conductor (two-pair twisted) station wire. 1000 feet (304.8 m) using 24 AWG. 1500 feet (457.2 m)
    using 22 AWG.
    Door Chime Box: 500 feet (152.4 m) using 24 AWG.
    Console: 1000 feet (304.8 m) using 24 AWG or 
    500 feet (152.4 m) if two consoles are used and one is
    used as a BLF (Busy Lamp Field)
    Background Music Specifications:
    Input Impedance: 600 OHMS
    Input Level: Nominal 250 
     Maximum Input: 1 Volt RMSLimit for Alarm Circuit:
    Loop Resistance: 1000 OHMS Max.
    Music On Hold Specifications: External  Paging  Specifications:
    Input Impedance: 600 OHMS Output Impedance: 600 OHMS
    Input Level: Nominal 250 
     Output Level: Nominal 250  Maximum Input: 1 Volt RMS Maximum Output: 400  RMS
    MECHANICAL SPECIFICATIONS
    Dimensions and Weights:
    KSU:
    Power Supply:
    Executive/Key Telephone:
    Door Chime Box:
    DSS Console:16.8 in.
    x 21.5 in. x 7.8 in.26.5 Ibs.
    430.0 mmx 550.0 mm
    x 200.0 mm12.0 kg
    12.1 in.
    x 14.2 in.
    x 4.8 in.12.8 Ibs.
    310.0 mmx 363.5 mm x 122.0 mm5.8 kg
    3.1 in.
    x 8.0 in. x 8.6 in.2.2 
    80.0 mmx 205.0 mm x 221.0 mm1.0 kg
    5.1 in.
    x 3.9 in. x 1.4 in.0.4 131.0 mmx 99.0 mm x 35.0 mm0.2 kg
    2.0 in
    x 7.4 in. x 8.8 in.1.3 Ibs.
    52.0 mmx 189.0 mm x 224.0 mm0.6 kg
    ENVIRONMENTAL SPECIFICATIONS
    Environmental Operating Conditions:
    Temperature:
    KSU and Telephones: 0 to 45 degrees C
    Door Chime Box: -20 to 60 degrees C
    Humidity: 10% to 95% noncondensing(32 to 113 degrees F)
    ( -4 to 140 degrees F) 
    						
    							Table 1-2SPECIFICATIONS,  PLUS 36
    GENERAL SPECIFICATIONS
    System Capacity:MAX. NO.System Capacity:MAX. NO.CO Lines12Speakerphones12
    Intercom Talkpaths6OPX Telephones18
    Stations 3 6
    ELECTRICAL SPECIFICATIONS
    Power Requirements: (AC Supply Must Be Dedicated)
     Supply Operating Range: 117 VAC  10%
    Power Dissipation:60 Hz  Hz
     Supply Unit: 480 Watts  4.1 Amps
    Grounding Requirements:1638 
    KSU Ground lug, 14 AWG or larger copper wire to cold water pipe or known good earth ground
    Cable Requirements:
    Four conductor (two-pair twisted) station wire. 1000 feet (304.8 m) using 24 AWG. 1500 feet (457.2 m)
    using 22 AWG.
    Door Chime Box: 500 feet (152.4 m) using 24 AWG.
    Console: 1000 feet (304.8 m) using 24 AWG or 500 feet (152.4 m) if two consoles are used and one 
    IS
    used as a BLF (Busy Lamp Field)
    Background Music Specifications:
    Input Impedance: 600 OHMS
    Input Level: Nominal 250 
     Maximum Input: 1 Volt RMSLimit for Alarm Circuit:
    Loop Resistance: 1000 OHMS Max.
    Music On Hold Specifications:External Paging Specifications:
    Input Impedance: 600 OHMS Output Impedance: 600 OHMS
    Input Level: Nominal 250 
     Output Level: Nominal 250  
    Maximum Input: 1 Volt RMS Maximum Output: 400  RMS
    MECHANICAL SPECIFICATIONS
    Dimensions and Weights:
    KSU:
    Power Supply:
    Executive/Key Telephone:
    Door Chime Box:
    DSS Console:16.8 in.
    x 21.5 in. x 7.8 in.33.9 Ibs.
    430.0 mm
    x 550.0 mm x 200.0 mm14.0 kg
    12.1 in.
    x 14.2 in. x 4.8 in.12.8 Ibs.
    310.0 mm
    x 363.5 mm x 122.0 mm5.8 kg
    3.1 in.
    x 8.0 in. x 8.6 in.2.2 Ibs.
    80.0 mmx 205.0 mm x 221.0 mm1.0 kg
    5.1 in.
    x 3.9 in. x 1.4 in.0.4 Ibs.
    131.0 mmx 99.0 mm x 35.0 mm0.2 k g
    2.0 in.
    x 7.4 in. x 8.8 in.1.3 Ibs.
    52.0 mm
    x 189.0 mmx 224.0 mm0.6 kg
    ENVIRONMENTAL SPECIFICATIONS 
    Environmental Operating Conditions:
    Temperature:
    KSU and Telephones: 0 to 45 degrees C
    Door Chime Box: -20 to 60 degrees C
    Humidity: 10% to 95% noncondensing(32 to 113 degrees F)
    ( -4 to 140 degrees F) 
    						
    							Table H-3 SPECIFICATIONS,  PLUS 64
    GENERAL SPECIFICATIONS
    System Capacity:MAX. NO.CO Lines 2 4
    Intercom Talkpaths
    6Stations64
    System Capacity:
    Speakerphones
    OPX TelephonesMAX. NO.24
    32
    ELECTRICAL SPECIFICATIONS
    Power Requirements: (AC Supply Must Be Dedicated)
    KSU/Power Supply Operating Range: 117 VAC 
     10%
    Power Dissipation:
    60 Hz  Hz
     Supply Unit: 870 Watts  7.4 Amps
    Grounding Requirements:2968 BTU/HI=.
    KSU Ground lug, 14 AWG or larger copper wire to cold water pipe or known good earth ground
    Cable Requirements:
    Four conductor (two-pair twisted) station wire. 1000 feet (304.8 m) using 24 AWG. 1500 feet (457.2m) using 22 AWG.
    Door Chime Box: 500 feet (152.4 m) using 24 AWG.Console: 1000 feet (304.8) using 24 AWG or 500 feet (152.4 m) if two consoles are used and one
    is used as a BLF (Busy Lamp Field)
    Background Music Specifications:
    Input Impedance: 600 OHMSInput Level: Nominal 250  Maximum Input: 1 Volt RMSLimit for Alarm Circuit:
    Loop Resistance: 1000 OHMS Max.
    Music On Hold Specifications:
    Input Impedance: 600 OHMS
    Input Level: Nominal 250 
     Maximum Input: 1 Volt RMS
    External Paging Specifications:
    Output Impedance: 600 OHMS
    Output Level: Nominal 250  Maximum Output: 400  RMS
    MECHANICAL SPECIFICATIONS
    Dimensions and Weights:
    KSU:27.8 in.
    x 26.1 in. x 8.5 in.81.6 Ibs.713.0 mm x 670.0 mm x 219.0 mm37.0 kg
    Power Supply:13.3 in.
    x 19.0 in. x 4.8 in.19.4 Ibs.340.0 mm x 488.5 mm x 122.0 mm8.8 kg
    Executive/Key Telephone:3.1 in.
    x 8.0 in. x 8.6 in.2.2 Ibs.
    80.0 mm
    x 205.0 mm x 221.0 mm1.0 kg
    Door Chime Box:5.1 in.
    x 3.9 in. x 1.4 in.0.4 Ibs.131 .O mm x 99.0 mm x  35.0  mm0.2 kg
    DSS Console: 2.0 in.x 7.4 in. x 8.8 in.1.3 Ibs.
    52.0 mm
    x 189.0 mm x 224.0 mm0.6 kg
    ENVIRONMENTAL SPECIFICATIONS
    Environmental Operating Conditions:
    Temperature:
    KSU and Telephones: 0 to 45 degrees C
    Door Chime Box: -20 to 60 degrees C
    Humidity: 10% to 95% noncondensing
    (32 to 113 degrees F)
    ( -4 to 140 degrees F) 
    						
    							BUSINESSCOM PLUS 
    ELECTRONIC KEYTELEPHONESYSTEMS
    SECTION 2,FEWTURES
    CONTENTSPAGECONTENTSPAGE
    1.INTRODUCTION..................... 2-2
    2. DESCRIPTION......................
    Automatic Intercom Answer...........
    Background Music (BGM)............. 2-2
    Call Duration Timer................. 2-2
    Call Forward With Follow-Me..........
    Call Monitor....................... 2-3
    Call Pickup.......................
    Call  Announced.............. 2-4
    Call Transfer Unannounced............ 2-4
    Call Waiting....................... 2-4
    Callback.........................
    Camp-On......................... 2-5
    CO Lines..........................
    2-5
    Common Use Line..................
    Component Commonality............. 2-6
    Conference, Add-On................. 2-6
    Conference, Meet-Me................
    Conference, Multi-Line............... 2-7
    Conference, Unsupervised............. 2-7
    Confirmation Tone..................
    2-8
    Dial Pulse To Tone (DTMF)
    Conversion......................
    Direct Inward System Access (DISA)..... 2-8
    Direct Station Selection (DSS).........
    Direct Station Selection (DSS)
    Console........................
    Do Not Disturb ...............
    Do Not Disturb (DND) Override
    By DSS Console..................
    Door Chime Box...................
    Dual Handsfree Hotline............ 2-10
    Excluded System Features............
    2-11
    Executive Call Forward..............
    Executive Override (Barge In).........2-12
    External Alarm Signals To
    Stations........................
    2-12
    Flash...........................
    Flexible Line Appearance............
    Flexible Station No. Assignment.......
    Group Hunt......................
    Group Hunt ................2-14
    Handsfree Reply On Intercom.........
    Hold............................2-15
    Intercom........................
    Last Number Dial..................
    Line ....................
    Message Waiting...................2-16
    Microphone On/Off................
    Music On Hold ..............
    Night Class Of Service...............2-17
    Night Transfer.....................
    Off-Premises Extension..............2-18
    Paging, All Call....................2-19
    Paging, All External Zone............2-19
    Paging, External Zone...............2-19
    Paging, Internal Zone...............
    Paging, Meet-Me..................
    Private Line......................2-20
    Recall Line Preference...............
    2-21
    Release Of Abandoned Calls
    ...................... 
    Remote Busy Line Indication..........2-21
    Ring 
    .....................2-22
    Ringing Line Preference.............2-22
    Room Monitor....................
    Save............................2-23
    Single Step Access.................
    Speed Dial.......................2-23
    Step Calling......................2-24
    Tenant Service ....................2-24
    Three Minute Warning Tone..........2-24
    Toll Restriction....................2-25
    Transfer Recall Display..............2-25 
    						
    							1.INTRODUCTION
       
    1.01This section lists and details the features available
    in the Businesscorn Plus  Both
    permanent and programmable features are discussed. This
    section should be used in conjunction with Section 4,
    SOFTWARE CONFIGURATION, when preparing the
    Program Record Form.
    2.DESCRIPTION
    2.01This section is formatted in the following manner:
    Description: discusses the basic elements of the feature.
    Conditions: lists and describes conditions that limit or
    enhance the feature under discussion.
    Basic Programming: lists required programming, i.e.,
    programming necessary for feature operation.
     Programming: lists programs that limit or enhance
    feature operation.
    Feature Interactions: lists features that directly affect the
    feature under discussion.
    AUTOMATIC INTERCOM ANSWER
    Description:
    This feature permits single-step answer of an internal call.
    Conditions: None
    Basic Programming: None
    Related Programming: None
    Feature Interactions:
    Intercom
    BACKGROUND MUSIC (BGM)
    Description:
    This feature permits station speakers and external zones to
    receive Background Music.
    Conditions:
    (a) BGM is a customer supplied item.
    (b) BGM can serve as a source of Music On Hold.
    (c) BGM is interrupted at a zone and/or station by an
    incoming call, and at a station by an outgoing call.
    (d) BGM is interrupted at stations utilizing Room Monitor.
    (e) BGM utilizes one Intercom link.
    Basic Programming:
    Program 26-Background Music
    Related Programming:
    Program l&External Paging Output
    Feature Interactions:
    CO Lines
    Hold
    Intercom
    Music On Hold (MOH)
    Room Monitor
    CALL DURATION TIMER
    Description:
    This feature permits a user to time the duration of an
    outgoing CO call.
    Conditions:
    (a) This feature is available only on Executive Display
    telephones.
    (b) The timer starts from 0 to 255 seconds after CO line
    seizure depending upon programming.
    (c) This feature can be manually started.
    (d) If a Hold is implemented during a CO call, the timer is
    disabled and the display returns to its normal condition. 
    						
    							Basic Programming:
    Program  Duration Timer
    Related Programming:
    Program  Duration Start Timer
    Feature Interactions:
    CO Lines
    Hold
    CALL FORWARD  FOLLOW-ME
    Description:
    This feature permits the automatic transfer of an incoming
    Intercom call to a second station (Call Forward). The
    destination of the forwarded call can be changed to yet a third
    station and so on (Follow-Me).
    Conditions:
    (a) The originating station can change the destination of the
    Call Forward.
    (b) Only the originating station can cancel a Call Forward.
    (c) The destination station can change the destination of the
    Follow-Me.
    (d) Program 49 (Excluded System Features) can disable this
    feature.
    (e) A call cannot be forwarded to a station that has invoked
    DND.
    (f) Executive Call Forward overrides Call Forward With
    Follow-Me.
    Basic Programming: None
    Related Programming:
    Program 49-Excluded System Features
    Feature Interactions:
    CO Lines
    Executive Call Forward
    Intercom
    CALL MONITOR
    Description:
    This feature permits the on-hook dialing of an Intercom or
    CO telephone number.
    Conditions:
    (a) Telephones without speakerphones must lift the handset
    to engage in a two-way conversation once the call is
    established.
    (b) The user can also monitor a CO call if placed on Hold.
    Basic Programming: None
    Related Programming: None
    Feature Interactions:
    CO Lines
    Intercom
    CALL PICKUP
    Description:
    This feature permits a station user to intercept an Intercom
    call intended for another station.
    Conditions:
    (a) Program 49 (Excluded System Features) can disable this
    feature.
    Basic Programming: None
    Related Programming:
    Program 49-Excluded System Features
    Feature Interactions:
    Intercom
    2-3 
    						
    							 
     
    CALL TRANSFER ANNOUNCED
    Description:
    Thisfeature permits the voice announced transfer of an
    established CO call.
     
    Voice Announce must be programmed.
    Program 49 (Excluded System Features) can disable this
    feature.
    If the transferred call is not answered within a
    programmed period of time, the call reverts back to the
    transferring station.
    This feature is accessible from a key telephone or DSS
    Console.
    Basic Programming:
    Program 24-Voice Announce /Tone Signal Call
    Related Programming:
    Program  Console Port Assignment
    Program 
     Transfer Timer
    Program 39-DSS Transfer Timer
    Program 49-Excluded System Features
     Feature Interactions:
    CO Lines
    Direct Station Selection (DSS) Console
    Intercom
    CALL TRANSFER UNANNOUNCED
    Description:
    This feature permits the transfer of an established CO call,
    with ringing, to a second station.
    Conditions:
      :
    (a) If the transferred call is not answered within a
    programmed period of time, the call reverts back to the
    transferring station.
    (b) Program 49 (Excluded System Features) can disable this
    feature.
    (c) This feature is accessible from a key telephone or a DSS
    Console.
    (d) Tone Signal must be programmed.
    Basic Programming:
    Program  Announce /Signal Tone Call
    Related Programming:
    Program  Console Port Assignment
    Program 
      Timer
    Program 39-DSS 
     Timer
    Program 49-Excluded System Features
    Feature Interactions:
    CO Lines
    Direct Station Selection (DSS) Console
    CALL WAITING
    Description:
    This feature permits two types of Call Waiting:
    (a) CO Call Waiting.
     Intercom Call Waiting.
    CO Call Waiting allows a station with a seized CO line to
    receive ringing for another incoming call on another line.
    Intercom Call Waiting allows a station with a seized Intercom
    link to receive ringing for another incoming Intercom call.
    Conditions:
    Intercom Call Waiting is unavailable at stations using
    Handsfree Reply On Intercom.
    ‘Iwo levels of Intercom Call Waiting are available through
    programming:
    (1) User-controlled: allows user to initiate the Call
    Waiting signal.
    (2) Automatic: the Call Waiting signal is automatically
    initiated.
    Callback and Camp-On are unavailable when the
    automatic mode of Intercom Call Waiting is in use.
    Call Waiting (CO) signals are blocked by all levels of Do
    Not Disturb when Do Not Disturb is in use. Intercom Call
    Waiting signals are blocked by Do Not Disturb (level 2
    and level 3 where LED lights steadily) when Do Not
    Disturb is in use.
    This feature is permanent for Intercom calls with respect
    to the DSS Console, i.e., the DSS Console has
    permanent override capabilities.
    Basic Programming:
    Program 16-CO Call Waiting
    Program 23-Intercom Call Waiting
    Related Programming ,
    Program  Console Port Assignment 
    						
    All TiE manuals Comments (0)

    Related Manuals for TiE Businesscom Plus 24/36/64 Installation Manual