    							427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   41 
    MIL-C-26482 Series 1 
    Shell Size  18 
    Insert Arrangement  32 
    Finish  Olive drab chromate over cadmium 
    Contacts Pines 
    Shell Style  Cable plug 
    Insert Position  Keyring 
     
    Break-Out Connector Cable  
    The PTZ-35x140™ also includes a break-out cable that connects to the system interface cable 
    with single terminal connectors. The break-out cable has the MIL-C-26482 Series 1 Connector 
    on one end and 4 pig-tail connectors and power leads as follows: 
     
     
    Figure 8-5: Break-Out Connector Cable 
    1. Four terminal ring leads for power: Input voltage range: 24 VDC ±10 % or 24 VAC ±10 % 
    rms (50/60Hz). Nominal static power consumption is 
    						
    							427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   42 
    9.0   DOCUMENT HISTORY 
     
    Revision Date Comments 
    100  Jan 2007  Initial Release 
    110  Aug 2007  Minor additions and corrections 
    120  Nov 2008  Added information regarding SR model, changed overall format to 
    match other Security cameras 
    130  Dec 2010  Corrected serial cable pin out labels; corrected EAR level to level 
    1; added clarification of location of ground lug 
    Added WEEE label and information 
    140  Aug 2011  Added Ethernet pinouts to system cable 
    Corrected DB-9 pin numbering in Section 3.8 Serial Control 
    Added FCC Regulatory information 
    Removed references to Nexus Console software 
    Added information regarding installation and use of FSM 
     
      
    						
    							427-0011-00-10 Revision 140     Copyright © FLIR Systems, Inc.   43 
    10.0 USER CONTROLS FOR KBD300A      
      
      
      
      
    Keystrokes  Function  Toggle Values (default to first value)
     
    Near button  Focus Near    
    Far button  Focus Far    
    CW Joystick  Zoom In   Increments from Wide to Tele  
    CCW Joystick  Zoom Out   Increments from Tele to Wide  
    1, Aux On IR Polarity to Black 
    Hot   
    1, Aux Off IR Polarity to White 
    Hot   
    2, Aux On  Set DLTV as active 
    For both commands and video  
    2, Aux Off  Set IR as active  For both commands and video 
    3, Aux On Toggle:  Plateau 
    Values  
    3, Aux Off  Toggle: AGC Type   
    4, Aux On  Autofocus 
    One shot Autofocus  
    4, Aux Off  IR FFC  Internal calibration 
    5, Aux Off  Toggle: LUT Palette  White, Black  
    6, Aux On  Toggle: DDE Gain  Dynamic Detail Enhancement 
    6, Aux Off  Toggle: AGC ROI  Full, Horizon, Sky, Ground, Center 
    7, Aux Off Toggle: Max Gain 
    Values  
    Note: the appropriate camera must be active to use associated camera functions. 
    To start, enter the Pelco Address then press CAM   
    						