    Have a look at the manual Telrad Digital DIGITAL Family Of Systems Administration, Installation And Upgrade Addendum Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 22 Telrad Digital manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							76-110-0175/G, Issue 2
    3-14 3.6.2SMDR Screen [YC-IS-F9]
    There is a new field in this screen:
    DID report to SMDR
    A new field has been added to designate whether or not DID num-
    bers are printed out in SMDR reports, in the ACC field.
    Legal values: Y (Yes), N (No).
    Default: N.
    3.6.3GENERAL PARAMETERS Screen [SP-PR]
    There are two new fields in this screen:
    ACD-IQ version
    In this field you designate which version of ACD-IQ is connected to 
    the system. If the version is 3.0 or higher, CID and DID numbers are 
    sent to ACD-IQ.
    Legal values: 0.0 - 15.15.
    Default: 0.0
    Send Directory Softkey
    Designate whether you want the idle display of Avanti 3025 stations 
    to show a Directory softkey or a Phone book icon. If you set this field 
    to Y, a Directory softkey appears. If you set this field to N, a Phone 
    book icon appears.
    Legal values: Y (Yes), N (No).
    Default: N.
    3.6.4PRIVATE TRUNK FEATURES Screen [PT-TF-F9]
    There is a new field in this screen:
    Disconnect Supervised
    If the trunk sends a signal to the DIGITAL system when the far end 
    disconnects, enter a Y in this field. If the trunk does not send a signal 
    when the far end disconnects enter N in this field.
    When Y is programmed in this field, the system allows this trunk to 
    connect to Meet Me Conference.
    Legal values: Y (Yes), N (No).
    Default: Y.
    3.6.5DID ROUTING Screen [RD]
    A new legal value has been added for each of the parameters Day 
    Routing and Night Routing. You can now enter DISA in either of 
    these fields.
    3.6.6TRUNK LIST Screen [GR-AG-F9]
    The new field in this screen is the same as in Section 3.6.4. 
    						
    							4-1 Section 4
    UPGRADE PROCEDURES4.1GENERAL
    You can upgrade an existing DIGITAL system from:
    •DIGITAL KEY BX Release SB3, SBU5, or SB6 to Release SB7;
    •DIGITAL 400 Release DB3, DBU5, or DB6 to Release DB7;
    •DIGITAL KEY BX to DIGITAL 400.
    The upgrade procedures are identical to those for upgrading from 
    Release 5 DIGITAL KEY BX AND DIGTAL 400 systems to Release6 
    systems and are described in the Release 6 Upgrade Manual, Cata-
    log No. 76-110-0455/F.
    There is only one minor change, as described below in Section 4.2.4.2DIGITAL KEY BX  CONFIGURATION FILE NAME CHANGE
    When upgrading DIGITAL KEY BX Release SB3, SBU5, or SB6 sys-
    tems to SB7, the original Release SB3, SBU5, or SB6 configuration 
    file is changed after the conversion. 
    The original file name with a .cfg extension, is changed to cfg.bak.4.3MANDATORY AND RECOMMENDED PROGRAMMING
    4.3.1Mandatory programming
    In the DIGITAL KEY BX Release SB7 and the DIGITAL 400 Release 
    DB7 systems, it is mandatory that the parameter Disconnect 
    Supervised be properly defined for every trunk in the system. This 
    field is found on the following screens:
    •TRUNK LISTS Screen (for trunk groups) -- path [GR-AG-F9];
    •ADDITIONAL TRUNK FEATURES Screen  (for private trunks) -- 
    path [PT-TF-F9].
    The Disconnect Supervised field should be programmed as Y if the 
    trunk sends a signal to the DIGITAL system when the far end discon-
    nects. If the trunk does not send a signal enter N in this field. 
    						
    							76-110-0175/G, Issue 2
    4-2 4.3.2Recommended programming
    It is recommended that for every loop-start or group-start analog cen-
    tral office outside line, the LENGTH field be defined as: Long. This 
    applies whether the outside line is connected to an MPD (DIGITAL 
    KEY BX systems only), COL, CHL, or COG card. 
    The LENGTH field appears on the following screens 
    (path [YC-SC-F9]):
    •MPD CARD UNITS DEFINITION Screen;
    •COL CARD UNITS DEFINITION Screen;
    •CHL CARD UNITS DEFINITION Screen;
    •COG CARD UNITS DEFINITION Screen.
    From the CARD CONFIGURATION Screen: 
    1.Place the cursor on the appropriate card (MPD, COL, CHL, or 
    COG).
    2.Press F9 to access the appropriate CARD UNITS DEFINITION 
    Screen.
    3.Move the cursor to the LENGTH field.
    4.Type: L.
    WARNING
    Only in special cases where the voice quality of
    the outside line has been successfully tested may
    the LENGTH field be programmed as S (Short) or
    V (Very long). 
    						
    							A-1 Appendix A 
    SUMMARY OF PROGRAMMING CHANGESA.1GENERAL
    This appendix provides a summary of the new fields and new values 
    used in programming the configuration file for the Release 7 
    DIGITAL KEY BX, DIGITAL 400, and DIGITAL 1000 systems.A.2NEW PROGRAMMING FIELDS AND VALUES
    Table A-1 provides a list of the new fields and new legal values in 
    found the configuration programming the Release 7 DIGITAL sys-
    tems. 
    Table A-1 New fields and values on the programming screens 
    PathFieldLegal valuesNotes
    YC-SC
    (see Sections 
    3.2.1 and 3.4.1)Card typeNew values: ULD, UHD, N24, N30
    YC-SC-F9
    (ULD or UHD 
    cards) -- see 
    Section 3.2.2DNUp to four digits including *, #
    StationE30, D30, S30, B30, M30, ATT
    PathS (Single Audio Path), D (Dual Audio Path)
    Add on 1
    DSS1 - DSS8 (Direct Station Select console), 
    VRC (voice recognition card), TAPI (DATALync data card), 
    PCAPP (APPLync data card) Add on 2
    Add on 3
    Add on 4
    YC-SC-F9
    (N24 or N30 
    cards) -- see 
    Section 3.4.2DNUp to four digits including *, #
    Public DNUp to 20 digits including *, # 
    						
    							76-110-0175/G, Issue 2
    A-2YC-CP-UP 
    (for N24 card)
    -- see Section 
    3.4.3 ProtocolDPNS, QSIG (default DPNS)
    Layer 2 sidefor DPNSS: A (A-side), B (B-side)
    for QSIG: M (master), S (slave)
    Layer 3 sidefor DPNSS: X (X-side), Y (Y-side)
    for QSIG: M (master), S (slave)
    Signaling channelfor N24 card D-channel for signaling: 1 - 24
    or N30 card D-channel for signaling: 1 - 31
    Back-to-back 
    connectionY (direct to peer), N (via CO)
    YC-CP-EP 
    (for N30 card) 
    -- see Section 
    3.4.3 Protocolfor N24 and N30 network cards: DPNS, QSIG (default 
    DPNS)
    Layer 2 sidefor DPNSS: A (A-side), B (B-side)
    for QSIG: M (master), S (slave)
    Layer 3 sidefor DPNSS: X (X-side), Y (Y-side)
    for QSIG: M (master), S (slave)
    Signaling channelfor N24 card D-channel for signaling: 1 - 24
    or N30 card D-channel for signaling: 1 - 31
    Back-to-back 
    connectionY (direct to peer), N (via CO)
    YS-IS-F9
    (with the cursor 
    on SMDR, press 
    F9) -- (see Sec-
    tion 3.6.2)DID report to 
    SMDRY (yes), N (no)
    SP-TM 
    (see Section 
    3.6.1)ISDN timer 302
    (for ISDN trunks)1 - 20 (seconds)
    Waiting tone time-
    out3 - 60 (seconds)
    Time for waiting 
    for next char.2 - 10 (seconds) Table A-1 New fields and values on the programming screens (continued)
    PathFieldLegal valuesNotes 
    						
    							Appendix A: SUMMARY OF PROGRAMMING CHANGES
    A-3 SP-FN 
    (see Section 
    3.5.1)Call Account 
    Monitor (FLNP 
    code and Fea-
    ture code)
    Up to four digits including *, # CLIR - Caller ID 
    Presentation 
    (FLNP code and 
    Feature code)
    Drop from confer-
    ence (FLNP code 
    and Feature 
    code)
    Internet connec-
    tion (FLNP code 
    only)
    Background 
    Music 9- 12 (for 
    DIGITAL 1000 
    system only; 
    FLNP code and 
    Feature code)
    Internal Page 9 - 
    16 (for DIGITAL 
    1000 system 
    only; FLNP code 
    and Feature 
    code)
    External Page 9 - 
    24 (for DIGITAL 
    1000 system 
    only; FLNP code 
    and Feature 
    code)
    Phone book pri-
    vate list (Feature 
    code only)
    Phone book lists 
    1 - 10 (Feature 
    code only)
    SP-PR 
    (see Section 
    3.6.3)ACD-IQ version0.0 - 15.15
    Send directory 
    softkeyY (Directory softkey will appear on the telephone display), 
    N (Phone book icon or softkey will appear on the telephone 
        display) Table A-1 New fields and values on the programming screens (continued)
    PathFieldLegal valuesNotes 
    						
    							76-110-0175/G, Issue 2
    A-4SP-SD-SG 
    (see Section 
    3.5.2)Group nameAny 10 characters
    SP-SD-NS 
    (see Section 
    3.5.3)Group 1 - 10 
    nameA - Z (capital letters), 0 - 9,  _ (underscore), / (slash), space
    PT-TF-F9 
    GR-AG-F9
    (see Section 
    3.6.4 and 3.6.6)Disconnect 
    supervisedY (The trunk sends a signal to the DIGITAL system when the 
        far end disconnects.), 
    N (The trunk does NOT send a signal to the DIGITAL system 
        when the far end disconnects.)
    GR-TF 
    (see Section 
    3.4.8)Max % for VC 
    (virtual channel)0 - 100 (0 = network support services disabled)
    FE-AT
     (see Section 
    3.2.5)Map TypeED (for Avanti 3025 and Avanti 3020), 
    SM (for Avanti 3015D and Avanti 3015), 
    BA (for Avanti 3000)
    FE-PK 
    (see Section 
    3.2.6)Map TypeED (for Avanti 3025 and Avanti 3020), 
    SM (for Avanti 3015D and Avanti 3015), 
    BA (for Avanti 3000)
    FE-PK-F9 
    (see Sections 
    3.2.7 and 3.5.4)Programmable 
    keysNew values: 
       BM 9 - 12 (Background Music for DIGITAL 1000), 
       PB PRV (private Phone book), 
       PB 1 - 10 (Phone books 1 - 10), 
       SP 90 - 99 (private speed dial)
    Other values: see the Administration manual, Release 6
    AT-AD 
    (see Section 
    3.2.3) ST20 ATT MAP1 - 4 (for all systems)
    5 -24 (for DIGITAL 1000 only)
    ST30 ATT MAP1 - 4 (for all systems)
    5 -24 (for DIGITAL 1000 only)
    AT-PK 
    (see Sections 
    3.2.4 and 3.5.4)Programmable 
    keysNew values: 
       PB PRV (private Phone book), 
       PB 1 - 10 (Phone books 1 - 10), 
       SP 90 - 99 (private speed dial)
    Other values: see the Administration manual, Release 6
    RD 
    (see Section 
    3.6.5)Day routingNew value: DISA
    Night routingNew value: DISA
    DS-DS 
    (see Section 
    3.3.1)MAP #1for DIGITAL KEY BX: 1, 5
    for DIGITAL 400: 1, 5, 9
    for DIGITAL 1000: 1, 5, 9, 13, 17, 21, 25, 29, 33, 37, 41, 45
    DS-PK 
    (see Section 
    3.3.2)Programmable 
    keysExtension DNs, SPxx (Speed Dial code), 
    ARxx (Automatic Redial code), - (None). Table A-1 New fields and values on the programming screens (continued)
    PathFieldLegal valuesNotes 
    						
    							Appendix A: SUMMARY OF PROGRAMMING CHANGES
    A-5 NT-FS 
    (see Section 
    3.4.4)3-party servicesY (feature supported), N (feature NOT supported)
    Callback busyY (feature supported), N (feature NOT supported)
    Callback no 
    answerY (feature supported), N (feature NOT supported)
    MessageY (feature supported), N (feature NOT supported)
    IVM supportedV5U (ImaGEN version 5.00U), V7 (ImaGEN version 7.00)
    NT-PR 
    (see Section 
    3.4.5)Feature setfor DIGITAL KEY BX: 1 - 16
    for DIGITAL 400: 1 - 32
    for DIGITAL 1000: 1 - 64
    NT-PR-F9 
    (see Section 
    3.4.6)Feature setfor DIGITAL KEY BX: 1 - 16
    for DIGITAL 400: 1 - 32
    for DIGITAL 1000: 1 - 64
    NT-NP 
    (see Section 
    3.4.7)Longest network 
    path1 - 31 Table A-1 New fields and values on the programming screens (continued)
    PathFieldLegal valuesNotes 
    						
    							76-110-0175/G, Issue 2
    A-6THIS PAGE INTENTIONALLY LEFT BLANK 
    						
    							INDEX
    INDEX-1 Numerics
    3-party services 3-9, A-4
    A
    account monitor A-3
    ACD-IQ 2-4, A-3
    adapter for DPNSS 2-11
    addressing mode 3-9
    administration 3-1–3-14, A-1 – A-5 
    APPLync card 2-4, 3-3
    Attendant definition screen 3-3, 3-4
    Avanti 
    APPLync card 2-4, 3-3
    configuration options 2-4
    DATALync card 2-4, 2-5, 3-3
    option module installation, 2-5 – 2-7
    programming telephone sets 3-2
    telephone set stand 2-5
    B
    Background Music A-3
    Back-to-back connection 3-8
    baud rate 3-1
    BGM A-3
    C
    callback busy A-5
    callback no answer A-5
    Caller ID Presentation A-3
    Card configuration screen 3-2, 3-7
    Card parameters screens 3-7
    CCB 3-9
    CCNA 3-9
    CLIR A-3
    coaxial cable, adapter for DPNSS 2-11
    configuration 
    Avanti telephone sets 2-4
    file name 4-1
    CRC4 3-9
    CRC6 3-9
    D
    data cards 
    description 2-4, 2-5
    installing 2-8, 2-9
    wiring connections 2-8DATALync card 2-4, 2-5, 3-3
    day routing A-4
    digital private network 2-11
    Direct Station Select console
    connecting 2-5, 2-9
    map 3-6, A-4
    DISA A-4
    disconnect supervised A-4
    documentation 1-2
    DPNSS  
    definition 2-11
    installing in UK 2-11, 2-12
    programming 3-7,A-2
    drop from conference A-3
    DSS console
    connecting 2-5, 2-9
    map 3-6, A-4
    E
    EHD card preparation 2-2
    ELD card preparation 2-2
    external page A-3
    F
    feature set 3-9, 3-10, A-4
    Features Set screen 3-9
    fields 3-2 – 3-14, A-1 – A-5
    Function access codes screen 3-12
    G
    generic functional protocol 2-12
    group name A-4
    I
    ImaGEN 3-10, A-5
    internal page A-3
    Internet connection A-3
    ISDN timer 302  3-13, A-2
    IVM 3-10, A-5
    L
    Layer 2 side 3-8
    Layer 3 side 3-8
    LEDs 2-2 
    						
    All Telrad Digital manuals Comments (0)

    Related Manuals for Telrad Digital DIGITAL Family Of Systems Administration, Installation And Upgrade Addendum Manual