Page 131
Mode Setting Initialize the settings for when the NX SOUND or GM LEVEL 2 mode is ON. 1.On the MIDI MENU display, select MODE SETTING. •The display looks similar to the following. 2.Select the mode. •There are two modes for GM LEVEL 2 depending on the parts to use. •The confirmation display appears. Press the YES button to execute the function, or press the NO button to cancel the function. •When using an external sequencer in GM LEVEL 2, select in the MIDI PRESETS options. Input/output Setting Make the...
Page 132
MIDI Presets Establish the optimum settings depending on how this Keyboard is connected to other equipment, and on whether this Keyboard is used as the master or the slave. 1.On the MIDI MENU display, select MIDI PRE- SETS. •The display looks similar to the following. 2.Use the and buttons to select the con- nection setup. •The PAGE 1/4 display shows connection setups with this instrument as the SLAVE. And the PAGE 2/4 display shows connection setups with this instrument as the MASTER. •The MASTER is...
Page 133
Program Change MIDI Out Use this function to immediately transmit specific PROGRAM CHANGE and BANK SELECT data from this display on a specified MIDI channel. 1.On the MIDI MENU display, select PROGRAM CHANGE MIDI OUT. •The display looks similar to the following. 2.Use the and buttons to select a function. MIDI CHANNEL: The MIDI channel to transmit to (1 to 16). PROGRAM CHANGE: Specify the PROGRAM CHANGE number to transmit (1 to 128). BANK SELECT MSB: Specify the BANK SELECT MSB to transmit (0 to...
Page 134
Computer Connection These settings are used to select the mode related to MIDI signal flow when a personal computer is connected to the USB terminal of this instrument. •When connecting to a personal computer, install the USB driver on the included CD-ROM to the computer first. (Refer to the separate manual for more information.) 1.Turn off the power to this instrument. 2.Connect a personal computer to the USB ter- minal on the rear of this instrument. 3.Turn on the power to this instrument. 4.On the...
Page 135
Initialize This instrument has many settable functions and storable memories. However, you can return the settings and memory to the factory-preset status. INITIAL 1.Press the PROGRAM MENUS button to turn it on. •The display changes to the following. 2.Select CONTROL. •The display looks similar to the following. 3.Select INITIAL. •This display changes to the following. 4.Use the and buttons to select the desired type of initialization. •PERFORMANCE includes all the items which are listed below it....
Page 136
Connections THEATRE SONIC EXT OUT (PR804) External rear speakers for the THEATRE SONIC effect can be connected to these terminals. (Refer to page 124.) AUX IN (input level 0.5 Vrms, 6 kΩ) Other instruments such as a sound generator can be con- nected to this terminal, and the sound will be output from this instrument’s speakers. To receive monaural sound, con- nect the other instrument to the R/MONO terminal. (Do not connect the L terminal.) LINE OUT (output level 1.5 Vrms, 600 Ω) By connecting an...
Page 137
Assembly (PR604) Follow the steps below to assemble your Technics piano. Make sure you are using the correct parts and that they are in the correct direction. •At least 2 people are required for assembly. •To disassemble the piano, reverse the procedure. 1.Remove the packing and take the parts out of the carton. Confirm that all the parts on the printed list are present. 2.The following parts are in the screw kit. 3.Affix the right and left side planks to the pedal box. (1)Use the 4 brass-colored screws...
Page 138
Assembly (PR804) Follow the steps below to assemble your Technics piano. Make sure you are using the correct parts and that they are in the correct direction.•At least 2 people are required for assembly.•To disassemble the piano, reverse the procedure. 1.Remove the packing and take the parts out of the carton. Confirm that all the parts on the printed list are present. 2.The following parts are in the screw kit. 3.Affix the pedal box to the speaker box. 4.Affix the right and left side panels to the...
Page 139
Symptoms which appear to be signs of trouble The following changes in performance may occur in the Technics Keyboard but do not indicate trouble. Phenomenon Remedy Sounds and effects The buttons, keys, etc. malfunction.•Turn off the POWER button once, then turn it on again. If this procedure is not successful, turn off the POWER button once. Then, while pressing the three lower left buttons in the RHYTHM GROUP section (SOUL & DISCO, GOSPEL & BLUES, COUNTRY & WESTERN) at the same time, turn the POWER...
Page 140
Phenomenon Remedy COMPOSER Storage is not possible.•The remaining memory capacity of the COMPOSER is 0. Setting the time signature and number of measures is not possible.•The time signature and number of measures cannot be changed for a pattern which is currently recorded in the COMPOSER. If you wish to change the time signature and/or measure data, first follow the procedure to clear the memory. (Refer to page 86.) The playback timing of the rhythm pattern is different from the timing with which it was...