Page 21
1-Introduction TASCAM CD-RW900 21 5−Recording The sampling frequency for CDs is 44.1 kHz. The CD- RW900 will always record (and play back) CDs at this frequency. H o w e v e r, i f re c o rd i n g t h ro u g h a d i g i t a l c o n n e c t i o n (either coaxial or optical) and the source has been re- corded at a frequency other than 44.1 kHz, or is being played back at a non-standard speed using a varispeed unit (more than 1% away from the standard), the CD- RW900’s internal frequency...
Page 22
1-Introduction 22 TASCAM CD-RW900 5−Recording Basic recording 1 Load a recordable disc into the unit. As the disc loaded, the display shows TOC Reading., with the period flashing. 2 Press the INPUT SELECT key to select a recording source (see “Input selection” on page 21). If a digital source is selected, and the connection or the signal are improper, the error message D-IN UN- LOCK! will appear on the display. 3 P re s s t h e R E C O R D k e y. T h e u n i t e n t e r s re c o rd...
Page 23
1-Introduction TASCAM CD-RW900 23 5−Recording Advanced recording Fade-in and fade-out recording At the beginning and end of recording, fade-in and fade-out effects can be performed. 1 During stop or recording standby mode, set the op- eration using the following menu options on the REC sub-menu (refer to “Operation basics” on page 14). FADE IN? The length of the fade in to the normal level can be set between 1 and 30 seconds in 1-second incre- ments (default setting: 3 seconds). FADE OUT? The...
Page 24
1-Introduction 24 TASCAM CD-RW900 When audio signal is not detected more than five sec- onds, the CD-RW900 automatically will stop recording and enters record standby mode. N O T E In the Sync 1 mode, if the unit detects the signal which is under the adjusted level over five secondsd, the Sync recording mode will be canceled. 3 To c a n c e l t h e S y n c re c o rd i n g m o d e , p re s s t h e SYNC REC key and select the Sync OFF. Record- ing returns to normal and continues till...
Page 25
1-Introduction TASCAM CD-RW900 25 5− Advanced Recording Rec mute function The Rec mute function allows instant cut-off of the input signal, and records four seconds of silence on the disc. While recording is in progress, press the REC MUTE key on the remote contorl. The display shows the Rec Mute flashing, the meters stop displaying the current level and the monitored sound is cut. After about four seconds, the unit enters record ready mode. N O T E This function is only available from the remote...
Page 26
26 TASCAM CD-RW900 Unfinalizing CD-RW discs If a CD-RW disc has been finalized, it is possible to erase the Table of Contents in the following way: 1 W ith the finalized disc loaded and the unit in stop mode, press the ERASE/DEL key on the front panel or the ERASE key on the remote control. Rortate the MULTI JOG dial or press the SKIP keys on the remote control to select UNFINALIZE?. Push the MULTI JOG dial or press the ENTER key to confirm. If you do not want to proceed with the unfinalizing...
Page 27
TASCAM CD-RW900 27 Erasing tracks This operation erases the specified track and all sub- sequent tracks from a recorded CD-RW disc. 1 During stop, press the ERASE/DEL key on the front panel or the ERASE key on the remote control. Se- lect the ERASE TRACK? rotating the MULTI JOG dial or pressing the SKIP keys on the remote con- trol. To c a n c e l t h e o p e r a t i o n a t t h i s p o i n t , p re s s t h e ERASE/DELor the ERASE key again. 2 Push the MULTI JOG dial or press the...
Page 28
28 TASCAM CD-RW900 T itles can be given to the disc and the tracks on the disc, using the TEXT EDIT option on the TEXT sub- menu. N O T E After the title is selected and entered on the disc, and TOC lights up on the dis-play, if the power is turned off, the TOC will not be recorded onto the disc, and the titles will not be added. Follow the guidelines below to input titles on the screen. Operate them when in the text edit mode. It is more efficient to connect a keyboard for title input ( refer to...
Page 29
TASCAM CD-RW900 29 Keyboard type setting The CD-RW900 must be set for the type of keyboard being connected. Set the type using the sub-menu KEYBOARD option on the SYSTEM sub-menu. Select US for an English- language keyboard, or JP for a Japanese-language keyboard. A computer keyboard can be connected to the IBM PC compatible PS/2 interface on the front panel to operate certain functions of the CD-RW900. It is particularly ef- ficient for title input. Title input by keyboard Titles can be input...
Page 30
30 TASCAM CD-RW900 Troublshooting SymptomPossible cause and remedy There is no power to the unit.Please check the power cord is properly plugged in. “Disc Error!” is displayed.The disc may be dirty. Please replace the disc. Playback is not possible.This may be due to condensation. In this case, remove the disc, turn the power on and wit a few hours, then try again. No sound is output.Confirm the connections with the audio system. Check the volume level, and proper amplifier operation. Recording is not...