Page 11

Panel Controls for the Software Programs
UR824  Operation Manual11
DAW Area
This is the area for configuring the DAW channel 
settings.
Level Meter
Indicates the signal level.
 Pan
Adjusts the pan.
Range:  L16 – C – R16
 Mute
Turns the mute on (lit) and off (dark).
 Solo
Turns the solo on (lit) and off (dark).
 Fader
Adjusts the signal level.
Range:  -∞ dB – +6.00 dB Master Area
This is the area for configuring the master channel 
settings.

Level Meter
Indicates the signal level.
 REV-X Send...

Page 12

Panel Controls for the Software Programs
UR824  Operation Manual12
REV-X Return Level
Adjusts the return level of the REV-X.
Range:  -∞ dB – +6.00 dB
 Pan
Adjusts the pan.
Range:  L16 – C – R16
 Mute
Turns the mute on (lit) and off (dark).
 Fader
Adjusts the signal level.
Range:  -∞ dB – +6.00 dB
MIX Area
This is the area for selecting the MIX you want to 
configure.
 MIX
Selects the MIX you want to configure.
You can copy the Main window settings of the 
MIX by dragging and dropping.
Headphone...

Page 13

Panel Controls for the Software Programs
UR824  Operation Manual13
DIGITAL MODE
Selects the input and output signal format of the 
OPTICAL A/B.
When ADAT is selected, the OPTICAL A/B 
terminals input and output signals of up to eight 
channels at 44.1 kHz and 48 kHz, or up to four 
channels at 88.2 kHz and 96 kHz. When S/PDIF is 
selected, the OPTICAL A/B terminals input and 
output signals of up to two channels at any 
available sample rate.
 LINE OUT
Selects the output signal of the LINE OUTPUT.
...

Page 14

Panel Controls for the Software Programs
UR824  Operation Manual14
Information Window
This window indicates  information about the 
dspMixFx UR824 and the device.
 Version Information
Indicates the version of the firmware and 
software. The letters “x.x.x” and “x.xx” indicate 
the version number.
 Check for update
Checks whether or not you have the latest 
software and firmware version, via the Internet. If 
a new version is found, follow the on-screen 
instructions for updating.
Dedicated Windows for...

Page 15

Panel Controls for the Software Programs
UR824  Operation Manual15
3.Click “Extended View Type/Can Hide State” 
in the input channel.
4.Click [Hardware].
The Input Settings window appears in the Mixer 
window as shown below.
In the VST Input Channel Settings Window 
(Cubase and Cubase Artist only)
1.[Devices]    [Mixer] to open the mixer.
2. Click “Edit Input Channel Settings” in the 
input channel.
The Input Settings window appears in the VST Input 
Channel Settings window as shown below.
In the VST...

Page 16

Panel Controls for the Software Programs
UR824  Operation Manual16
Panel Controls
Input Settings Window
+48V
Indicates the on/off status of the phantom power 
function of the device.
 Phase
Turns on (lit) and off (dark) the phase inversion of 
the signal.
 High Pass Filter
Turns on (lit) and off (dark) the high pass filter.
To select the cutoff frequency of the high pass 
filter, use the “Settings Window” (page 18) in the 
section “Dedicated Windows for Cubase Series.”
 Channel Strip Edit
Opens the...

Page 17

Panel Controls for the Software Programs
UR824  Operation Manual17
Hardware Setup Window
Headphones Window
This is the window for selecting the output signal of 
the PHONES on the device. 
Phones 1
Selects the output signal of PHONES 1.
 Phones 2
Selects the output signal of PHONES 2.
Reverb Routing Window
This is the window for configuring the “REV-X” (page 
20) settings.
REV-X Edit
Opens the “REV-X” (page 20) setup window.
 REV-X Type
Selects the REV-X type.
Option:  Hall, Room, Plate
 REV-X Time...

Page 18

Panel Controls for the Software Programs
UR824  Operation Manual18
Master Level
Indicates the output signal level of the LINE 
OUTPUT.
 Master Level knob
Adjusts the output signal level of the selected 
(highlighted) LINE OUTPUT signal. Please note 
that this Master Level  Knob will not appear when 
selecting a LINE OUTPUT with a checkmark on 
the Knob Control.
 Reset
Sets the output signal level of all LINE OUTPUT 
signals not selected in the Knob Control to 0 dB.
Settings Window
This is the window...

Page 19

Panel Controls for the Software Programs
UR824  Operation Manual19
Panel Controls
Common to Compressor and Equalizer
MORPH
Adjusts the parameter of the Sweet Spot Data.
You can simultaneously adjust the compressor 
and equalizer settings which are set to five points 
around this knob by turning this knob. When you 
set the knob to the middle of adjacent two points, 
the compressor and equalizer settings will be set 
to an intermediate value.
 Sweet Spot Data
Selects the Sweet Spot Data (page 26).
...

Page 20

Panel Controls for the Software Programs
UR824  Operation Manual20
Equalizer
Equalizer Curve
This graph indicates the characteristics of the 3-
band equalizer. The vertical axis indicates the 
gain, and the horizontal axis indicates the 
frequency. You can adjust LOW, MID, and HIGH 
by dragging each handle in the graph.
 LOW F
Adjusts the center frequency of the low band.
Range:  20.0 Hz – 1.00 kHz
 LOW G
Adjusts the gain  of the low band.
Range:  -18.0 dB – +18.0 dB
 MID Q
Adjusts the band width of...
Start reading Steinberg UR824 Operation Manual

Related Manuals for Steinberg UR824 Operation Manual

All Steinberg manuals