Steinberg Ci1 Operation Manual
Have a look at the manual Steinberg Ci1 Operation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Steinberg manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CI1 Operation Manual11 The Controls and Connectors English Rear Panel USB terminal This terminal is used to connect the CI1 and the computer by using the included USB cable. PHONES jack A pair of headphones can be plugged in here. This jack outputs the mixed signal from the ana- log input jacks and the signal from a DAW or other audio software. The output level can be adjusted using the PHONES control. This out- put signal is not affected by the MASTER con- trol. LINE OUT jacks L/R These jacks would typically be connected to monitor speakers (powered speakers). These jacks output the mixed signal from the analog input jacks and the signal from a DAW or other audio software. The output level can be ad- justed using the MASTER control. NOTE The volume balance between the analog input signal and the application software like DAW output signal can be adjusted using the MIX control. MIC/LINE/HI-Z jack 1/L (analog input jack 1)/ MIC/LINE jack 2/R (analog input jack 2) Microphones and instruments such as guitars can be connected here using XLR or phone jack cables. The signal received by these jacks is sent to the LINE OUT jacks and computer. NOTE You can directly connect an electric guitar or electric bass without the need for a separate DI box or amp simulator to analog input jack 1. In this case, turn on ( 0) the [HI-Z] button on the fr ont panel. Make sure to use an unbalanced phone cable when you connect an electric guitar or electric bass. If you use a balanced cable, it will not work correctly.
12CI1 Operation Manual Software Installation English Software Installation To use the CI1, you must first install the software on the computer. This section explains the soft- ware installation. Install Sequel LE/WaveLab LE in the STEINBERG SOFTWARE PACKAGE FOR CI1 DVD-ROM, then install the Yamaha Steinberg USB Driver in the TOOLS for CI1 CD-ROM. NOTE Before installing the software, confirm the “System Requirements for Software” on page 7. The latest information (e.g. OS compatibility, software update, etc.) is available on the following Steinberg website. http://www.steinberg.net/en/support.html Installing Sequel LE/ WaveLab LE To install the Sequel LE/WaveLab LE, there are two steps: • Software installation • User registration NOTE The “User registration” requires an Internet connection. Software installation Install the software using the STEINBERG SOFTWARE PACKAGE FOR CI1 DVD-ROM. Follow the instructions below. 1.Start the computer and log on to the Ad- ministrator account. 2.Insert the STEINBERG SOFTWARE PACKAGE FOR CI1 DVD-ROM into the DVD-ROM drive. 3.When the “WELCOME TO SEQUEL LE AND WAVELAB LE” window appears, click the corresponding national flag icon to choose your preferred language. NOTE If this window does not appear automatically, open the DVD-ROM then double-click the file “CI1 Start Center.” 4.Click “Install (software name).” 5.Follow the onscreen instructions to in- stall the software. User registration Register your personal information on “MySteinberg” in the Steinberg website. See the following website for details. https://www.steinberg.net/en/mysteinberg.html Installation for Sequel LE/WaveLab LE is now complete.
CI1 Operation Manual13 Software Installation English Installing TOOLS for CI1 TOOLS for CI1 consists of software component: Yamaha Steinberg USB Driver. Yamaha Steinberg USB Driver enables communication between the CI1 and your computer. The TOOLS for CI1 Installer installs this software component. Follow the instructions below to install the component. Windows: ......................................... page 13 Mac OS X: ....................................... page 15 Windows Preparing to install 1 1. Disconnect all the devices other than the mouse and keyboard from the com- puter. 2.Start the computer and log on to the Ad- ministrator account. Exit any open applications and close all open windows. Preparing to install 2 (Windows XP only) For Windows Vista/Windows 7 users, this set- ting is not necessary. Go on to step 6. 3.Select [Start] ( [Settings] ) [Control Panel], click “Switch to Classic View” in the upper left of the window. NOTE After completing the installation, make sure to re- store the original settings if necessary. 4.Go to [System] [Hardware] [Driver Signing] [Driver Signing Options], and select the radio button to the left of “Ig- nore – Install the software anyway and don't ask for my approval” and click [OK]. NOTE After completing the installation, make sure to re- store the original settings if necessary. 5.Close the System Prop erties window by clicking the [OK] button or the Close button ([X]) to close the Control Panel. Software Installation 6. Insert the TOOLS for CI1 CD-ROM into the CD-ROM drive. 7.Open the CD-ROM, then double-click the file “setup.exe.” A “Welcome to the InstallShield Wizard for Yamaha Steinberg USB Driver” window appears. (Windows Vista/Windows 7) If the “User Account Control” window appears, click [Continue] or [Yes]. 8.Click [Next] to start the installation. To cancel the installation, click [Cancel]. 9.When a message appear s indicating that the software has been installed, click [Finish]. 10.When a window appears requiring you to restart your computer, follow the on- screen instructions to restart the com- puter. 11.Connect the CI1 directly to the computer (without using a hub) by using the in- cluded USB cable.
14CI1 Operation Manual Software Installation English Initial settings of driver (Windows XP only) For Windows Vista/Windows 7 users, the initial settings of the driver are set automatically. Go on to step 15. 12.The “Found New Hardware Wizard” win- dow appears. Some computers may take a while to display the window. A dialog box may appear asking you whether you wish to connect to Windows Update. In this case, select the radio but ton to the left of “Not at this time,” then click [Next]. 13.Select the radio button next to “Install the software automatically” then click [Next]. If a message “The software you are installing has not passed Windows Logo Testing” ap- pears, click [Continue Anyway]. You do not need to abort the installation. 14.When a message appears indicating that the installation has been completed, click [Finish]. Confirming the installation 15. Select [Control Panel] from the Start menu. 16.Open the Device Manager window as follows. (Windows Vista/Windows 7) Select [Hardware and Sound], then click [De- vice Manager]. If the “User Account Control” window appears, click [Continue] or [Yes]. (Windows XP) Double-click on the System icon to call up the System Properties window, then select the Hardware tab and clic k [Device Manager]. 17.Click on the [+] mark or [>] mark next to “Sound, video and game controllers,” and confirm that “Steinberg CI1” is listed. The installation is now complete.
CI1 Operation Manual15 Software Installation English Mac OS X Software Installation 1. Disconnect all the devices other than the mouse and keyboard from the com- puter. 2.Insert the TOOLS for CI1 CD-ROM into the CD-ROM drive of your computer. 3.Open the CD-ROM, then double-click the file “Yamaha Steinberg USB Driver.mpkg.” 4.A dialog box appears asking if you want to install the software. Click [Continue]. The “Welcome to the Yamaha Steinberg USB Driver Installer” window appears. 5.Click [Continue]. The “Installation Type” window appears 6.Click [Install]. The “Authenticate” window appears. 7.Enter the Administrator name and the password, then click [OK]. A message appears prompt ing you to restart the computer after the installation. 8.Click [Continue Installation] The “Install” window appea rs indicating the in- stallation progress. When the installation is complete, the “Summary” window appears. 9.Click [Restart] to restart the computer. 10.Connect the CI1 directly to the computer (without using a hub) by using the in- cluded USB cable. Confirming the installation (Mac OS X 10.5) For Mac OS X 10.6 users, go on to step 13. 11.From the hard disk to which the OS is installed (usually Macintosh HD), click [Applications] [Utilities], then double- click [Audio MIDI Setup]. The “Audio MIDI Setup” window appears. 12.Click [Audio Devices], then select “Steinberg CI1” from the pull-down menu in [Properties For]. The current audio settings are shown in the [Audio input] and [Audio Output] fields. NOTE By selecting “Steinberg CI1” for [Default Output] in System Settings, you can output audio signals of the system sounds and audio player software (e.g., iTunes, etc.) from the CI1. The installation is now complete. Confirming the installation (Mac OS X 10.6) 13. From the hard disk to which the OS is installed (usually Macintosh HD), click [Applications] [Utilities], then double- click [Audio MIDI Setup]. The “Audio Devices” window appears. 14.Select “Steinberg CI 1” from the list of audio devices. The current audio settings are shown in the right side of the window. NOTE By selecting “using this device for sound output” in the Action menu at the left bottom of the window, you can output audio signals of audio player soft- ware (e.g., iTunes, etc.) from the CI1. The installation is now complete.
16CI1 Operation Manual Connecting to an External Device English Connecting to an External Device Connection Examples Options Microphone stand adaptor A Yamaha BMS-10A microphone stand adaptor can be attached to the underside of the CI1. The CI1 attached with the microphone stand adaptor can then be used with a conventional microphone stand. HeadphonesComputer Powered monitor speakers Electric guitar Microphone BMS-10A
CI1 Operation Manual17 Audio driver settings of the software English Audio driver settings of the software This section explains the audio driver setup with Sequel LE/WaveLab LE. Sequel LE 1.Start Sequel LE. 2.Click the [Program Setting Page] icon in the bottom left corner of the screen. 3.Click the right side of “Audio Connec- tion” in the “Audio Settings” section, then select “Yamaha Steinberg USB ASIO (Windows)” or “Steinberg CI1 (Mac).” 4.When “Do you want to switch the ASIO driver?” window appears, click [Switch]. Setup is now complete. For instructions on using Sequel LE, refer to the PDF manual, available from [Help] in the [File] menu on the upper left corner of the screen. WaveLab LE 1.Start WaveLab LE. 2.Select [Option] in the WaveLab menu, then click [Audio Streaming Settings]. 3.Select “Yamaha Steinberg USB ASIO (Windows)” or “Steinberg CI1 (Mac)” from the list of Audio Devices. 4.Click [OK]. Setup is now complete. For instructions on usin g WaveLab LE, refer to the manual, available from [Help] in the Wave- Lab menu. TIP Setting the audio driver buffer size Noise produced when using audio applications such as DAW software may affect audio re- cording and/or playback. In most cases, you can solve these problems by adjusting the au- dio driver buffer size (the size of memory used to temporarily hold data to avoid intermittent playback). The buffer si ze can usually be ad- justed via the audio driver setup window in the application. (When using ASIO compatible soft- ware for Windows, the buffer size can be ad- justed in the ASIO Buf fer Size parameter via the Control Panel of the Yamaha Steinberg USB Driver.) While the higher buffer size re- duces load to the computer CPU but produces latency (time lag) duri ng recording/playback, the smaller buffer size may result in noise or the sound cutting off. Make sure to set the buf- fer size to an appropriate value depending on the performance of your computer, the number of audio/MIDI tracks being recorded/played back on the DAW software, the number of plug-in software, and so on. For more information on this product, please visit the following Steinberg website: http://www.steinberg.net/
18CI1 Operation Manual Troubleshooting English Troubleshooting The power of the device does not turn on. • Make sure that the CI1 is properly con-nected to the computer via a USB cable. The USB bus-power is necessary to use the CI1. • Confirm whether or not a proper USB ca-ble is used. If the USB cable is brok en or damaged, have the USB cable replaced with a known working one. Use a USB cable no longer than 1.5 meters. • Connect the CI1 to a computer without a USB hub. No sound. • Make sure that the MASTER/PHONES/ MIX controls are set properly. • Are your speaker cables connected properly? Refer to “Connection Examples” on page 16. • Are your speaker cables shorted? • Are the volume controls of your sources, audio devices, applications software, computer operating system, etc., set at appropriate levels? • (Windows only) Is the output of your com- puter operating system muted? • Do you have several applications running at the same time? Be sure to quit all applications you are not using. Noise occurs, or the sound is intermittent or distorted. • Is the PEAK indicator flashing red? You might have to lower GAIN control level to avoid distortion. • Does your computer satisfy the system requirements? Refer to “System Requirements” on page 7. • Is the buffer size setting of the Yamaha Steinberg USB Driver set properly? Refer to the “Setting the audio driver buffer size” on page 17. • Are any other applications, device drivers, or USB devices (scanners, printers, etc.) running at the same time? Be sure to quit all app lications you are not using. • Are you playing back a large number of audio tracks? The number of tracks you can play at the same time will depend on the performance of the com- puter you are using. You may experience inter- mittent playback if you exceed your computer's capabilities. • Are you recording or playing long continu-ous sections of audio? The audio data processing capabilities of your computer will depend on a number of factors in- cluding CPU speed and access to external de- vices. • Is the network adaptor running? Disable the suspected network adaptor. Some network adaptors can cause noise.
CI1 Operation Manual19 Uninstalling the TOOLS for CI1 English Uninstalling the TOOLS for CI1 To uninstall TOOLS for CI1, you must remove the following software component. • Yamaha Steinberg USB Driver Windows 1.Disconnect all other USB devices except mouse and keyboard from the com- puter. 2.Log on to the Administrator account. Exit any open applications and close all open windows. 3.Open the window for the uninstall oper- ation as follows. (Windows Vista/Windows 7) From the Start menu, select [Control Panel] [Uninstall a Program] to call up the “Uninstall or change a program” panel. (Windows XP) From the Start menu, select ([Settings] ) [Control Panel] [Add or Remove Programs] to display the Add or Remove Programs panel. Click “Change or Remove Programs” located in the upper left. 4.Select “Yamaha Steinberg USB Driver” from the list. 5.Uninstall them as follows. (Windows Vista/Windows 7) Click the [Uninstall]/[Uninstall/Change]. If the “User Account Control” window appears, click [Continue] or [Yes]. Follow the on-screen instructions to remove the software. (Windows XP) Click [Change/Remove]/[Remove]. Follow the on-screen instructions to remove the software. Mac OS X Remove the following folders and files from the boot disk (usually Macintosh HD). /System/Library/Extensions YamahaSteinbergUSBAudio.kext /Application/Yamaha/USBDriver/ Yamaha Steinberg US B Control Panel.app /Library/PreferencePanes/ Yamaha Stei nberg USB.prefPane /Library/Preferences/ com.yamaha.YamahaSte inbergUSBDriver.plist /Library/Audio/MIDI Drivers/ YamahaSteinbergUSBMIDI.plugin /Library/Audio/MIDI Devices/Yamaha/Images/ USB_1500.tiff USB_1502.tiff /Library/Receipts/ YamahaSteinbergUSBAudioDriver.pkg YamahaSteinbergUS BControlPanel.pkg YamahaSteinbergUSBDriverplist.pkg YamahaSteinbergUSBMIDIPlugIn.pkg YamahaSteinbergUSBMIDIIcon.pkg YamahaSteinbergUSBPrefPane.pkg
20CI1 Operation Manual Appendix English Appendix Input and Output Specifications General Specifications Specifications and descriptions in this manual are for information purposes only. Steinberg/Yamaha Corp. reserves the right to change or modify products or specifications at any time without prior notice. Since specifications, equip- ment or options may not be the same in every locale , please check with your Steinberg/Yamaha dealer. Analog Input Type Input Level Nominal Level Maximum Level Input Impedance MIC 1/L, 2/R XLR type, balanced +48V Phantom powered -60dBu — -16dBu -6dBu 3k Ω HI-Z 1/LPhone type, unbalanced-44dBu — 0dBu +10dBu 500kΩ LINE 1/L, 2/RTRS phone type, balanced-34dBu — +10dBu +20dBu 62kΩ Analog Output Type Output Level Nominal Level Maximum Level Input Impedance LINE OUT L, R TRS phone type, impedance balanced +4dBu +10dBu 10k Ω PHONESTRS phone type, stereo3.6mW 6.0mW 40Ω USB TerminalUSB1.1, 44.1/48 kHz, 24bit, bus-powered Dimensions (W x H x D)W190 x H44.6 x D134.5 mm Net Weight640 g Included Accessories• Operation Manual • TOOLS for CI1 CD-ROM • STEINBERG SOFTWARE PACKAGE FOR CI1 DVD-ROM •USB cable