Page 41
KSU Installation3-7 Chapter 3 - System Installation Figure 3-3: Connecting Cabinet 0 and Cabinet 1
Page 42
3-8KSU Installation Chapter 3 - System Installation Figure 3-4: Mounting Cabinets 0, 1, & 2 48.3”
Page 43
KSU Installation3-9 Chapter 3 - System Installation KSU Grounding To ensure proper system operation and for safety purposes, a good earth ground is required. A metallic cold water pipe usually provides a reliable ground. Carefully check that the pipe does not contain insulated joints that could isolate the ground path. If insulated joints exist, another earth ground source must be used or, if allowed, the joints may be bridged. A #14 insulated AWG or larger copper wire should be used between the ground...
Page 44
3-10KSU Installation Chapter 3 - System Installation Power Line Surge Protection The AC outlet should be equipped with an additional power line transient surge protection device. Systems using such devices are more resistant to damage from power line surges than unprotected systems. Power line surges often occur during switching operations and especially during violent thunderstorm activity. Protector Specifications-- Installation of a surge protector meeting these specifications prevents or minimizes...
Page 45
KSU Installation3-11 Chapter 3 - System Installation Optional Mounting Racks Mounting Rack (Floor Model) 1. To install on the floor, use the optional foot. 2. To install the second or third Cabinets, use the screws provided to connect them as in Figure 3-6. 3. The installation position of the optional foot can be adjusted according to the environment. Figure 3-6: Mounting Rack
Page 46
3-12KSU Installation Chapter 3 - System Installation Optional Rack (Cabinet Model) 1. To mount rack, use the optional BRK (Bracket for installation on the rack). Usable rack is the standard 19”rack. Any 19”open rack can be used. 2. After placing the rack on a flat floor, attach the Cabinet to the rack using provided BRK with bolts and nuts on both sides as shown inFigure 3-7. Figure 3-7: Optional Rack
Page 47
Ring Generator Unit Installation 3-13 Chapter 3 - System Installation Ring Generator Unit Installation The Ring Generator Unit (RGU3) is needed if a SLIB is to be installed in a Cabinet. The RGU3 provides ring voltage and a Message Wait Source. A cable for connecting the RGU3 and KSU is provided. 1. Mount the unit inside the Cabinet to the bottom side panel on the right with the two screws provided. 2. Connect the unit to the backplane via CN14 connector (marked on PCB). PowerSupplyUnitInstallation The...
Page 48
3-14PCB Installation Chapter 3 - System Installation Before Installation-- Ensure that the AC plug connected to Cabinet 0 is NOT plugged into the AC outlet. 1. Place the PSU in the left-most slot in Cabinet 0, aligning the card guides with the PSU PCB and PSU frame flanges. 2. Slide the PSU into place using the injectors to seat the PSU fully in the Cabinet. 3. Then affix the PSU to the Cabinet with the two screws provided. Figure 3-8: PSU Installation PCB Installation PCB Handling and General...
Page 49
Main Processing Board Installation 3-15 Chapter 3 - System Installation Removing a PCB Reverse theInserting a PCBprocedure. Installation method of the PCB is shown inFigure 3-9. There is a ground tab located on the top and bottom of each PCB toward the front end of the card.Thereisalsoagroundtablocatedtotherightofeachcardguideineachcabinet.Make sure when the PCBs are inserted into the card guide and secured in their respective card slots, that the ground tab on each card mates with the ground tab on each...
Page 50
3-16 Main Processing Board Installation Chapter 3 - System Installation DIP Switch Positions (SW3) The MPB also has an eight-position DIP switch, SW3. The default setting is: All ON position. The function of each switch position is as follows: Before programmingthe system, dip switch 8 (database default switch) should be placed in the on position and power cycled off and on to initialize the system database to default. Once the database has been initialized, switch 8 should be placed in the off position...