    Owner’s Manual 
    						
    							IMPORTANT SAFETY INSTRUCTIONS
    To reduce risk of injury from fire or electric
    shock, always follow bask safety precautions
    when using this product.
    The safety symbol (exclamation point
    inside a triangle) on the Attendant
    ConnecT/R alerts you to the Important operat-
    ing and maintenance instructions below.
    1.
    2.
    3.
    4.
    Read and understand all instructions in this
    Owners Manual.
    Observe all warnings and instructions
    marked on the product.
    Unplug this product from wall outlets and
    telephone jacks before cleaning. Clean
    exposed parts with a soft, damp cloth. Do
    not use liquid or aerosol cleaners, and never
    immerse in water.
    Do not use the product near water or when
    you are wet. For example, do not use it in a
    wet basement or near a swimming pool,
    bathtub, shower, sink, or laundry tub. If the
    product comes in contact with any liquids,
    unplug the power and line cords immedi-
    5.
    6.
    7.
    8.
    9.
    ately.  Do not plug the product back in until
    it has been dried thoroughly.
    Install this product securely on a stable
    surface. Damage may result if the product
    falls.
    Install this product in a protected location
    where no one can step on or trip over power
    and line cords. Do not place objects on the
    cords that may cause damage or abrasion.
    Do not allow anything to rest on the power
    cord. Do not locate this product where the
    cord will be abused by persons walking on
    it. Do not overload wall outlets, as this can
    result in the risk of fire or electric shock.
    Never push objects of any kind into this
    product through housing openings because
    they may touch dangerous voltage points or
    short out parts, resulting in possible fire or
    electric shock.
    If this product does not operate normally,
    see the Troubleshooting section of this 
    						
    							manual. If you cannot resolve the problem,
    or if the product is damaged, Call the AT&T
    Helpline at 1-800-628-2888. Do not open the
    product. Opening the product may expose
    you to dangerous voltages or other risks.
    10. During thunderstorms, avoid using tele-
    phones except cordless models. There may
    be a slight chance of electric shock  from
    lightning.
    11. Do not use a telephone in the vicinity of a
    gas leak.  If you suspect a gas leak, report it
    immediately, but use a telephone away from
    the area where gas is leaking.
    12. This product should be operated only from
    the type of power source indicated on the
    power transformer (see Item 13, below). lf
    you are not sure of the type of power supplyto your business or home, consult your local
    power company.
    13. Use only a UL Listed wall plug-in power
    transformer that has Class 2 outputs and
    the following characteristics:
    Input rating:
    99-127 V AC rms 60 Hz
    150 mA maximum
    Output rating:
    27-35 V DC at 200 mA
    14-18 V DC at 200 mA
    The power transformer supplied with the
    product has these characteristics.
    SAVE THESE INSTRUCTIONS 
    						
    							Table of Contents
    Introduction1
    Installation3
    Step  1— Mount the SPIRIT® Attendant ConnecT/R4
    Step   2—Connect the SPIRIT  Attendant  ConnecT/R5
    Step  3—Test the Equipment7
    Troubleshooting8
    Appendix A—Wiring Requirements9
    Appendix B—Warranty10
    While reasonable efforts were made to ensure that the information in this document was complete and
    accurate at the time of printing, AT&T assumes no responsibility for any errors. Changes or corrections to
    the information contained in this document maybe incorporated into future re-issues.
    Document No. 518-453-712Comcode 106455868
    Copyright © 1991 AT&TIssue 1
    All Rights ReservedJanuary 1991
    Printed in USA. 
    						
    							Introduction
    The following descriptions define important
    terms used in this manual.l    The SPIRIT Attendant is a device which
    provides automated call-handling capabili-
    ties for the SPIRIT Communications System.
    The SPIRIT
    ® Communications System
    Attendant ConnecT/R provides you withThis Owner’s Manual will help you set up your
    the ability to add a SPIRIT Attendant to
    SPIRIT Attendant ConnecT/ R for your particu-
    your SPIRIT System. It connects to thelar business needs.
    controller.
    The controller is the central processor
    through which all SPIRIT calls in your
    company are processed.
    Figure 1. SPIRIT Attendant ConnecT/R
    l   SPIRIT is a registered trademark of AT&T.
    1 
    						
    							2
    Figure 2. SPIRIT Attendant ConnectT/R Applications 
    						
    							Installation
    1.
    2.
    INSTALLATION INSTRUCTIONS3.   Never touch uninsulated telephone wires or
    terminals unless the telephone line has been
    Never install telephone wiring during adisconnected at the network interface.
    Iightning storm.
    4.   Use caution when installing or modifying
    Never install telephone jacks in wet loca-telephone lines.
    tions unless the jack is specifically designed
    for wet locations.
    Directly connected by a cord from one unit to the
    other, or connected via a wiring run.
    Figure 3. SPIRIT Attendant ConnecT/R with Attached SPIRIT Attendant
    NOTE:  The switches on the SPIRIT Attendant ConnecT/R are not used. They have
    been removed to prevent accidental incorrect installations.
    3 
    						
    							4
    Step 1— Mount the SPIRIT Attendant
    ConnecT/R (optional).
    The SPIRIT Attendant ConnecT/R is designed
    to be placed on your desk or mounted on any
    vertical surface.  Do not place it on the floor.
    Hardware has been included to mount the
    SPIRIT Attendant ConnecT/R on the wall: two
    plastic wall-mount tabs, two anchors, and two
    #6 screws.of the tab against the inside of one of the
    feet.  Repeat for the second tab.
    1.
    2.
    3.
    4.
    Select an appropriate location. The SPIRIT
    Attendant ConnecT/R can be no more than
    six feet from its power supply (an AC outlet
    that isn’t controlled by a wall switch) and no
    more than six feet from the devices attached
    to it. The bottom of the SPIRIT Attendant
    ConnecT/R should be at least two feet from
    the floor.
    Position the SPIRIT Attendant ConnecT/R
    so the side with the jacks and settings is
    down or to the side, but not up.
    Remove the backing from the plastic tabs.
    Gently position a tab by aligning the end of
    the adhesive with the outside edge of the
    SPIRIT Attendant ConnecT/R and the side
    5.
    6.
    7.Press the tabs firmly into position.
    With the tabs at the top, hold the SPIRIT
    Attendant ConnecT/R against the wall
    where you plan to mount it and use a pencil
    to mark the location of the holes in the tabs.
    The bottom of the SPIRIT Attendant
    ConnecT/R should be at least two feet from
    the floor.
    If you have plywood walls or walls with a
    sturdy supporting structure (either wood 
    						
    							studs or cross members), partially screw the
    two screws into the wall at the marks,
    remove them, hang the tabs on the screws,
    and then tighten the screws.
    For plaster, plasterboard, cinder block, or
    brick surfaces, drill a 3/16 hole at each
    mark and insert an anchor into each of the
    holes. Gently tap each anchor with a ham-
    mer until it is flush with the surface. Screw
    the screws partially into the anchors, remove
    them, hang the tabs on the screws, and then
    tighten the screws.
    Step 2 — Connect the SPIRIT Attendant
    ConnecT/R to the controller and the SPIRITAttendant to the SPIRIT Attendant
    ConnecT/R.
    Please check the cabling requirements in Appen-
    dix A before proceeding. Consult with the
    person who customized your SPIRIT System
    before attaching the SPIRIT Attendant
    ConnecT/R to the controller.
    NOTE: The 4-wire cord mentioned in the
    steps below comes with the SPIRIT Atten-
    dant ConnecT/R. Any cord you may have
    that is connecting a SPIRIT Telehone to
    the controller is also 4-wire cord .
    5 
    						
    							6
    1.   Connect the SPIRIT Attendant ConnecT/R
    to the Controller. Using 4-wire cord, plug
    one end into the CTRLR jack on the back of
    the SPIRIT Attendant ConnecT/R and
    connect the other end into the STATION jack
    on the controller.
    2.   Connect the SPIRIT Attendant to the
    SPIRIT Attendant ConnecT/R. Using the
    line cord provided with the SPIRIT Atten-
    dant, plug one end into the LINE jack (or its
    equivalent) on the back of the SPIRIT
    Attendant and connect the other end to the
    TEL DEVICE jack on the SPIRIT Attendant
    ConnecT/R.
    3.   Do not connect a SPIRIT Telephone to the
    SPIRIT Attendant ConnecT/R.
    4.   Connect the SPIRIT Attendant ConnecT/R
    to the AC power outlet. Plug the power
    connector into the POWER jack on the back
    of the SPIRIT Attendant ConnecT/R. To
    prevent the power cord from pulling out
    easily, make a small loop of cord near the
    power connector and slip it behind the strain
    relief tab next to the POWER jack on the
    SPIRIT Attendant ConnecT/R. Plug the
    wall transformer into an AC power outlet
    that is at least 3 feet away from the controller
    and not controlled by a wall switch. (If it is
    any closer to the controller, you may hear a
    hum on your SPIRIT System.) 
    						