Page 41

41Specifications
Others
Power 
requirementsVPL-FH35: 100 V to 240 V AC, 4.6 A to 1.9 A, 50/60 
Hz
VPL-FH30: 100 V to 240 V AC, 4 A to 1.6 A, 50/60 Hz
VPL-FX35: 100 V to 240 V AC, 3.8 A to 1.6 A, 50/60 
Hz 
VPL-FX30: 100 V to 240 V AC, 3.3 A to 1.3 A, 50/60 
Hz
Power 
consumptionAC 100 V to 
120 VVPL-FH35: 460 W
VPL-FH30: 400 W
VPL-FX35: 380 W
VPL-FX30: 330 W
AC 220 V to 
240 VVPL-FH35: 440 W
VPL-FH30: 380 W
VPL-FX35: 360 W
VPL-FX30: 310 W
Standby power 
requirementsAC 100 V to 
120 VVPL-FH35/FH30:
9W...

Page 42

42Specifications
The values for mass and dimensions are approximate.
*1: For details, refer to “Acceptable Input Signals” on page 44.
*2: Available for VPL-FH35/FH30 only
*3: Not all optional accessories are available in all countries and area. Please check with your local 
Sony Authorized Dealer.
*4: Information on accessories in this manual is current as of Dec. 2011.
*5: To attach the projection lens to the projector, the PK-F30LA1 projection lens adapter is required.
Design and specifications of the...

Page 43

43Specifications
Others
Pin assignment
DVI-D connector (DVI-D, female) RGB input connector (Mini D-sub 15-
pin, female)
RS-232C connector (D-Sub 9-pin, 
female)
1 T.M.D.S.
Data2–14 +5 V Power
2 T.M.D.S.
Data2+15 Ground (return 
for +5 V)
3 T.M.D.S.
Data2 Shield16 Hot Plug 
Detect
4 NC 17 T.M.D.S
Data0–
5 NC 18 T.M.D.S 
Data0+
6 DDC Clock 19 T.M.D.S 
Data0 Shield
7 DDC Data 20 NC
8NC 21NC
9 T.M.D.S.
Data1–22 T.M.D.S 
Clock Shield
10 T.M.D.S.
Data1+23 T.M.D.S
Clock+
11 T.M.D.S.
Data1 Shield24 T.M.D.S...

Page 44

44Specifications
HDMI connector (HDMI, fermale)Acceptable Input Signals
Computer signal
1 T.M.D.S.
Data2+11 T.M.D.S.
Clock Shield
2 T.M.D.S.
Data2 Shield12 T.M.D.S.
Clock–
3 T.M.D.S.
Data2–13 NC
4 T.M.D.S.
Data1+14 RECERVED 
(N.C.)
5 T.M.D.S.
Data1 Shield15 SCL
6 T.M.D.S.
Data1–16 SDA
7 T.M.D.S.
Data0+17 GND
8 T.M.D.S.
Data0 Shield18 +5V Power
9 T.M.D.S.
Data0–19 Hot Plug 
Detect
10 T.M.D.S.
Clock+ResolutionfH [kHz]/
fV [Hz]Input connector
RGB*1DVI-D*2/
HDMI*3 *6
640 × 350   31.5/70 z–
37.9/85 
z–
640 ×...

Page 45

45Specifications
Others
Digital TV signal
Analog TV signal
*1: INPUT A, INPUT B
*2: INPUT C
*3: INPUT D
*4: INPUT A
*5: Available for VESA Reduced Blanking 
signals only.*6: Available for VPL-FH35/FH30 only
*7: INPUT C is determined as a computer 
signal; INPUT D is determined as a digital 
TV signal.
 When a signal other than the signals listed in 
table is input, the picture may not be 
displayed properly.
 An input signal meant for screen resolution 
different from that of the panel will not be...

Page 46

46Specifications
Combinations of Input Signals (VPL-FH35/FH30 only)
Sub
 picture
Main 
pictureINPUT A 
(RGB/
YP
BPR)
INPUT B 
(RGB)INPUT C 
(DVI-D)INPUT D 
(HDMI)S VIDEOVIDEO
INPUT A 
(RGB/
YP
BPR)z––
––
INPUT B 
(RGB)
–––––
INPUT C 
(DVI-D)
–
z–––
INPUT D 
(HDMI)
–
z–––
S VIDEO
–
z–– –
VIDEO
–
z––– 

Page 47

47Projection Distance and Lens Shift Range
Others
Projection Distance and Lens Shift Range
The projection distance refers to the distance between the front of the lens and the projected 
surface.
The lens shift range represents the distance in percent (%) by which the lens can be shifted from 
the center of the projected image. The lens shift range is regarded as 0% when the point (A) in 
the illustration (point where a line drawn from the center of the lens and the projected image 
cross at right...

Page 48

48Projection Distance and Lens Shift Range
Projection distance (VPL-FH35/FH30)
Unit: m (inches)
Projection distance formula (VPL-FH35/FH30)
D: Projected image size (Diagonal) Unit: m (inches)
Lens shift range (VPL-FH35/FH30)
Projection image sizeProjection distance L
DiagonalWidth × HeightStandard lensVPLL-Z1024VPLL-Z1032
80 (2.03 m)1.72 × 1.08
(68 × 42)2.39 – 3.83
(95 – 150)4.00 – 5.48
(158 – 215)5.45 – 8.32
(215 – 327)
100 (2.54 m)2.15 × 1.35
(85 × 53)3.00 – 4.80
(119 – 189)5.03 – 6.87
(198 – 270)6.84...

Page 49

49Projection Distance and Lens Shift Range
Others
Projection distance (VPL-FX35/FX30)
Unit: m (inches)
Projection distance formula (VPL-FX35/FX30)
D: Projected image size (Diagonal) Unit: m (inches)
Lens shift range (VPL-FX35/FX30)
Projection image sizeProjection distance L
DiagonalWidth × HeightStandard lensVPLL-Z1024VPLL-Z1032
80 (2.03 m)1.63 × 1.22
(64 × 48)2.31 – 3.69
(91 – 145)3.85 – 5.28
(152 – 207)5.24 – 8.01
(207 – 315)
100 (2.54 m)2.03 × 1.52
(80 × 60)2.89 – 4.62
(114 – 182)4.84 – 6.62
(191 –...

Page 50

50Projection Distance and Lens Shift Range
About lens position
The projection distance and lens shift range are measured with the lens position adjusted to the 
center. To adjust the lens position to the center, follow the procedures below:
1Rotate the left lens shift dial left or right 
then align the screws with the v V marks 
in four places, as illustrated, for adjusting 
the lens horizontally.
2Rotate the right lens shift dial clockwise 
until the lens is fixed, to adjust the lens 
vertically.
Before...
Start reading Sony Projector VPL FH35/FH30 User Manual

Related Manuals for Sony Projector VPL FH35/FH30 User Manual

All Sony manuals