Home > Sony > Camcorder > Sony Pmv F5 Manual

Sony Pmv F5 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Sony Pmv F5 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 980 Sony manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Setup Menu List61
    Settings
    FlareSetting the flare 
    correctionSetting
    On / OffTurns the flare correction function on/off.
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Custom,” and 
    this setting is locked to “Off” when “Shooting Mode” is set to 
    “Cine EI.”)
    Master Flare
    –99 to +99 (±0)Sets the user adjustment value for master flare of the flare 
    correction that is caused by the camcorder.
    R Flare
    –99 to +99 (±0)Sets the user adjustment value for R flare of the flare 
    correction that is caused by the camcorder.
    G Flare
    –99 to +99 (±0)Sets the user adjustment value for G flare of the flare 
    correction that is caused by the camcorder.
    B Flare
    –99 to +99 (±0)Sets the user adjustment value for B flare of the flare 
    correction that is caused by the camcorder.
    GainSetting for the 
    GainMode
    ISO / dBSelects the gain setting mode.
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Custom.”)
    Gain
    
    When “Mode” in “Gain” is set to 
    “ISO,” and “Gamma Category” is 
    set to “STD” or “HG (HG1/HG2/
    HG3/HG4)”
    ISO 800 to ISO 6400
    When “Mode” in “Gain” is set to 
    “ISO,” and “Gamma Category” is 
    set to “HG (HG7/HG8)”
    ISO 1600 to ISO 12500
    When “Mode” in “Gain” is set to 
    “ISO,” and “Gamma Category” is 
    set to “S-Log2” or “S-Log3”
    ISO 2000 to ISO 16000
    
    When “Mode” in “Gain” is set to 
    “ISO,” and “Gamma Category” is 
    set to “STD” or “HG (HG1/HG2/
    HG3/HG4)”
    ISO 500 to ISO 4000
    When “Mode” in “Gain” is set to 
    “ISO,” and “Gamma Category” is 
    set to “HG (HG7/HG8)”
    ISO 1000 to ISO 8000
    When “Mode” in “Gain” is set to 
    “ISO,” and “Gamma Category” is 
    set to “S-Log2” or “S-Log3”
    ISO 1250 to ISO 10000
    When “Mode” in “Gain” is set to 
    “dB”
    –3dB / 0dB / 3dB / 6dB / 9dB / 
    12dB / 18dBSets the gain.
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Custom.”)
    When the CBK-55BK is attachedThe setting value that follows the position of the GAIN/EI 
    switch on the CBK-55BK is displayed.
    Camera
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List62
    Settings
    Exposure Index
    
    500EI to 8000EI (2000EI)
    
    320EI to 5000EI (1250EI)Sets the EI value.
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Cine EI.”)
    Note
    The Highlight Latitude values for each EI value are follows:
    
    500EI: 4.0E / 640EI: 4.3E / 800EI: 4.7E / 1000EI: 5.0E / 
    1250EI: 5.3E / 1600EI: 5.7E / 2000EI: 6.0E / 2500EI: 6.3E 
    / 3200EI: 6.7E / 4000EI: 7.0E / 5000EI: 7.3E / 6400EI: 
    7.7E / 8000EI: 8.0E
    
    320EI: 4.0E / 400EI: 4.3E / 500EI: 4.7E / 640EI: 5.0E / 
    800EI: 5.3E / 1000EI: 5.7E / 1250EI: 6.0E / 1600EI: 6.3E / 
    2000EI: 6.7E / 2500EI: 7.0E / 3200EI: 7.3E / 4000EI: 7.7E 
    / 5000EI: 8.0E
    When the CBK-55BK is attachedThe setting value that follows the position of the GAIN/EI 
    switch on the CBK-55BK is displayed.
    Highlight Latitude
    4.0E to 8.0E (6.0E)Displays the Highlight Latitude value according to the 
    “Exposure Index” setting.
    Gain/EI Switch 
    (Only when the CBK-55BK is 
    attached)
    See “Gain” or “Exposure Index” 
    for the selectable items.
    Default setting: Same value as 
    the “Gain” setting for 
    “Custom,” “800EI” for “Cine 
    EI”Sets the L level of the GAIN/EI switch on the CBK-55BK.
    Note
    When “Shooting Mode” in “Base Setting” of the System 
    menu is set to “Custom,” the selectable items are same as the 
    selections in “Gain.” When “Shooting Mode” in “Base 
    Setting” of the System menu is set to “Cine EI,” the selectable 
    items are same as the selections in “Exposure Index.”
    Gain/EI Switch 
    (Only when the CBK-55BK is 
    attached)
    See “Gain” or “Exposure Index” 
    for the selectable items.
    Default setting: Double the 
    value of the default setting of 
    “Gain” for “Custom,” same 
    value as the default setting of 
    “Exposure Index” for “Cine EI”Sets the M level of the GAIN/EI switch on the CBK-55BK.
    Note
    When “Shooting Mode” in “Base Setting” of the System 
    menu is set to “Custom,” the selectable items are same as 
    them in “Gain.” When “Shooting Mode” in “Base Setting” of 
    the System menu is set to “Cine EI,” the selectable items are 
    same as them in “Exposure Index.”
    Gain/EI Switch 
    (Only when the CBK-55BK is 
    attached)
    See “Gain” or “Exposure Index” 
    for the selectable items.
    Default setting: Four times the 
    value of the default setting of 
    “Gain” for “Custom,” Double 
    the value of the default setting 
    of “Exposure Index” setting for 
    “Cine EI”Sets the H level of the GAIN/EI switch on the CBK-55BK.
    Note
    When “Shooting Mode” in “Base Setting” of the System 
    menu is set to “Custom,” the selectable items are same as 
    them in “Gain.” When “Shooting Mode” in “Base Setting” of 
    the System menu is set to “Cine EI,” the selectable items are 
    same as them in “Exposure Index.”
    Camera
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List63
    Settings
    Remote Gain L
    –3dB / 0dB / 3dB / 6dB / 9dB / 
    12dB / 18dBSets the gain switch L level for RM (such as RM-B150, etc.).
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Custom.”)
    Remote Gain M
    –3dB / 0dB / 3dB / 6dB / 9dB / 
    12dB / 18dBSets the gain switch M level for RM (such as RM-B150, etc.).
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Custom.”)
    Remote Gain H
    –3dB / 0dB / 3dB / 6dB / 9dB / 
    12dB / 18dBSets the gain switch H level for RM (such as RM-B150, etc.).
    (This setting is available only when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Custom.”)
    Shockless Gain
    On / OffTurns the shockless gain function on/off.
    Camera
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List64
    Settings
    ShutterSpecifying 
    operating 
    conditions of the 
    electronic shutterSetting
    On / OffTurns the electronic shutter function on/off.When the CBK-55BK is attachedThe setting value that follows the position of the SHUTTER 
    switch on the CBK-55BK is displayed.
    Mode
    Speed / AngleSelects modes of the electronic shutter.
    Select
    Step / ContinuousSelects the setting method for the electronic shutter speed.
    Shutter Value Sets the shutter speed/angle.
    Speed mode: Shutter speed
    Angle mode: Shutter angle.
    Setting value differs depending on the format setting and the 
    “Select” setting in “Shutter.”
    When “Mode” is set to “Speed”
    When “Mode” is set to “Angle”
    Step Select
    Execute / CancelChanges the preset value for “Shutter Value” (8 types) of the 
    “Step” setting in “Select.”
    Add: Adds a step shutter value. When 8 steps are already 
    registered, delete a step shutter value by using “Delete” to 
    make the space for adding the new step shutter value.
    Delete: Deletes a registered step shutter value.
    Step 1~8: Displays a registered step shutter value.
    Camera
     Menu itemsSub items and setting valuesContents
    Format settingStepContinuous
    59.94P 1/100 / 1/120 / 1/125 / 1/250 / 1/500 / 
    1/1000 / 1/2000 / 1/40001/60 to 1/8000
    59.94i 1/60 to 1/7000
    50P
    50i1/60 / 1/100 / 1/120 / 1/125 / 1/250 / 
    1/500 / 1/1000 / 1/20001/50 to 1/7000
    29.97P 1/50 / 1/60 / 1/120 / 1/125 / 1/250 / 
    1/500 / 1/1000 / 1/20001/30 to 1/8000
    25P 1/30 / 1/50 / 1/60 / 1/100 / 1/250 / 
    1/500 / 1/1000 / 1/20001/25.02 to 1/7000
    When “S&Q Motion” is set to “On”
    1/30 to 1/7000
    24P 1/48 / 1/50 / 1/60 / 1/120 / 1/250 / 
    1/500 / 1/1000 / 1/20001/24.02 to 1/6000
    When “S&Q Motion” is set to “On”
    1/30.02 to 1/6000
    23.98P 1/48 / 1/50 / 1/60 / 1/120 / 1/250 / 
    1/500 / 1/1000 / 1/20001/23.99 to 1/6000
    When “S&Q Motion” is set to “On”
    1/30.03 to 1/6000
    Format settingStepContinuous
    59.94P
    59.94i216.0 / 180.0 / 120.0 / 90.0 / 45.0 / 22.5 / 11.2 / 5.6359.7 to 4.2
    50P
    50i
    300.0 / 180.0 / 150.0 / 90.0 / 45.0 / 22.5 / 11.2 / 5.6
    29.97P216.0 / 180.0 / 120.0 / 90.0 / 45.0 / 22.5 / 11.2 / 5.625P300.0 / 180.0 / 150.0 / 90.0 / 45.0 / 22.5 / 11.2 / 5.624P
    23.98P180.0 / 172.8 / 144.0 / 90.0 / 45.0 / 22.5 / 11.2 / 5.6 
    						
    							Setup Menu List65
    Settings
    Slow ShutterSetting the slow 
    shutterSetting
    On / OffTurns the slow shutter function on/off.
    (You cannot change the on/off setting while recording.)
    Number of Frames
     2 / 3 / 4 / 5 / 6 / 7 / 8Sets the number of frames to accumulate for the slow shutter.
    Auto ExposureSetting the auto 
    adjusting for the 
    video level (This 
    setting is available 
    only for a lens that 
    is compatible with 
    the iris control 
    function.)Level
    +2.0 to –2.0 (±0)Sets the desired control level (bright/dark) for auto iris.
    Speed
    –99 to +99 (±0)Sets the control speed for auto iris.
    Clip High light
    On / OffTurns on/off the function that makes dull the response for 
    high luminance by ignoring the detection of high luminance 
    area.
    Detect Window
    1 to 6 (1)Selects the type of the detect window.
    Detect Window Indication
    On / OffTurns on/off the function that displays the frame of the detect 
    window as a marker.
    Camera
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List66
    Settings
    S&Q MotionSetting the Slow & 
    Quick Motion 
    functionSetting
    On / OffTurns the Slow & Quick Motion function on/off.
    This setting is not available when “Rec Format” of the System 
    menu is set to the following settings.
     MPEG 1920 × 1080/1280 × 720
     SStP SR-SQ 444/422
     SStP SR-Lite 422
    (This setting is not available when “Main Operation” in “Base 
    Setting” of the System menu is set to “RGB.”
    High Frame Rate Mode
    Off / Full Scan / Center ScanSets the high speed shooting method more than 60P.
    Off: High speed shooting is not performed.
    Full Scan: Performs high speed shooting with the picture 
    angle of Super 35 mm size.
    Center Scan: Performs high speed shooting with half size of 
    picture angle of Super 35 mm size on the center area of a 
    picture.
    Note
    When “Imager Scan Mode” in “Base Setting” of the System 
    menu is set to “2K Full,” this setting is locked to “Full Scan.” 
    When “Imager Scan Mode” in “Base Setting” of the System 
    menu is set to “2K Center,” this setting is locked to “Center 
    Scan.”
    Frame Rate
    1 to 240 (24)Sets the frame rate for the Slow & Quick Motion recording.
    Note
    Available settings are follows.
    When “High Frame Rate Mode” is set to “Off”
    1 to 60 (24)When “High Frame Rate Mode” is set to “Full Scan” or 
    “Center Scan”
     When “Main Operation” in “Base Setting” of the System 
    menu is set to “RAW,” and “Rec Control” of the Recording 
    menu is set to “AXS”
    —72, 75, 80, 90, 96, 100, 110, 120, 125, 135, 144, 150, 
    160, 168, 175, 180, 240
     When “Main Operation” in “Base Setting” of the System 
    menu is set to “RAW,” and “Rec Control” of the Recording 
    menu is set to “SxS&AXS”
    —72, 75, 80, 90, 96, 100, 110, 120, 125, 135, 144, 150, 
    160, 168, 175, 180 (system frequency: 23.98/24/29.97/
    59.94)
    —72, 75, 80, 90, 96, 100, 110, 120, 125, 135, 144, 150 
    (system frequency: 25/50)
     When “Main Operation” in “Base Setting” of the System 
    menu is set to “YPbPr”
    —72, 75, 80, 90, 96, 100, 110, 120, 125, 135, 144, 150, 
    160, 168, 175, 180 (system frequency: 23.98/24/29.97/
    59.94)
    —72, 75, 80, 90, 96, 100, 110, 120, 125, 135, 144, 150 
    (system frequency: 25/50)
    (This setting is not available when “Main Operation” in “Base 
    Setting” of the System menu is set to “RGB.”
    Camera
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List67
    Settings
    Color BarsSetting the Color 
    BarsSetting
    On / OffTurns the color bars on/off.
    Type
    ARIB / SMPTE / 75% / 100%Selects the type of color bar.
    Noise 
    Suppression
    Setting the noise 
    suppressionSetting
    On / OffTurns the noise suppression function on/off.
    (The default settings is “Off” when “Shooting Mode” in 
    “Base Setting” of the System menu is set to “Cine EI.”)
    Level
    Low / Mid / HighSets the noise suppression level.
    Flicker ReduceSetting Flicker 
    CompensationMode
    Auto / On / OffSet the operation of the Flicker-Reduction function.
    Frequency
    50 Hz / 60 HzSet to the power supply frequency of the light source causing 
    flicker.
    Image 
    Inversion
    Setting the image 
    inversion functionSetting
    Normal / V InvSets the image inversion.
    Lens InterfaceSetting the lens 
    interfaceSetting
    Type C / Type A / Type C+12P / 
    Type A+12P / OffSelects the lens interface according to the connected lens 
    type.
    When using an optional LA-FZB1/FZB2 mount adapter, 
    select “Type C.”
    When using the lens mount adapter with Lens 12 pin (service 
    parts), select “Type C+12P” or “Type A+12P.”
    Note
    If changing this setting while the lens attached to the 
    camcorder, turn the camcorder off, then turn it on.
    Zoom Limit
    Off / Zoom Range 1 / Zoom 
    Range 2Sets the limit for the zoom operation range of the power 
    zoom.
    Camera
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List68
    Settings
    The Paint menu settings are available only when “Shooting Mode” in “Base Setting” (page 90) of the 
    System menu is set to “Custom.”
    Paint Menu
    Paint
     Menu itemsSub items and setting valuesContents
    GammaAdjusting the 
    gamma 
    compensationSetting
    On / OffTurns the gamma compensation function on/off.
    Step Gamma
    0.35 to 0.90 (0.45)Sets the gamma compensation value in 0.05 steps.
    Master Gamma
    –99 to +99 (±0)Adjusts the master gamma level.
    R Gamma
    –99 to +99 (±0)Adjusts the R gamma level.
    G Gamma
    –99 to +99 (±0)Adjusts the G gamma level.
    B Gamma
    –99 to +99 (±0)Adjusts the B gamma level.
    Gamma Category
    STD / HG / User / S-Log2 / 
    S-Log3Select from among “STD” (standard gamma), “HG” (hyper 
    gamma), “User” (user gamma), “S-Log2,” or “S-Log3.”
    Gamma Select
    When “Gamma Category” is set to 
    “STD”
    STD1 DVW / STD2 ×4.5 / 
    STD3 ×3.5 / STD4 240M / 
    STD5 R709 / STD6 ×5.0
    When “Gamma Category” is set to 
    “HG”
    HG1 3250G36 / HG2 4600G30 
    / HG3 3259G40 / HG4 
    4609G33 / HG7 8009G40 / 
    HG8 8009G33
    When “Gamma Category” is set to 
    “User”
    User 1 / User 2 / User 3 / User 
    4 / User 5
    When “Gamma Category” is set to 
    “S-Log2”
    S-Log2
    When “Gamma Category” is set to 
    “S-Log3”
    S-Log3Selects the gamma table that is used for the gamma 
    compensation.
    Black GammaAdjusting the 
    black gamma 
    compensationSetting
    On / OffTurns the black gamma compensation function on/off.
    (This setting is available only when “Gamma Category” in 
    “Gamma” of the Paint menu is set to “STD.”)
    Range
    LOW / HIGHSelects the black gamma correction effective range.
    LOW: 0 to 3.6%
    HIGH: 0 to 28.8%
    Master Black Gamma
    –2 to +2 (±0)Sets the master black gamma level. 
    						
    							Setup Menu List69
    Settings
    KneeAdjusting the knee 
    compensationSetting
    On / OffTurns the knee compensation function on/off.
    (This setting is available only when “Gamma Category” in 
    “Gamma” is set to “STD.”)
    Point
    75% to 109% (90%)Sets the knee point.
    Slope
    –99 to +99 (±0)Sets the knee slope.
    Knee Saturation
    On / OffTurns the knee saturation function on/off.
    Knee Saturation Level
    –99 to +99 (±0)Adjusts the knee saturation level.
    White ClipAdjusting the 
    white clippingSetting
    On / OffTurns the white clipping adjustment on or off.
    (This setting is available only when “Gamma Category” in 
    “Gamma” is set to “STD” or “HG.”)
    Level
    When the system frequency setting 
    is 59.94, 29.97, or 23.98.
    90.0% to 109.0% (108.0%)
    When the system frequency setting 
    is 50, 25, or 24.
    90.0% to 109.0% (105.0%)Sets the white clip level.
    Paint
     Menu itemsSub items and setting valuesContents 
    						
    							Setup Menu List70
    Settings
    DetailSetting the detail 
    adjustingSetting
    On / OffTurns the detail adjusting function on/off.
    Level
    –99 to +99 (±0)Adjusts the detail level.
    H/V Ratio
    –99 to +99 (±0)Adjusts the ratio between the H detail level and V detail level.
    Crispening
    –99 to +99 (±0)Adjusts the crispening level.
    Level Depend
    On / OffTurns the level depend adjustment function on/off.
    Level Depend Level
    –99 to +99 (±0)Adjusts the level depend level.
    Frequency
    –99 to +99 (±0)Sets the center frequency of the H details signal.
    (Setting the center frequency higher decreases the details.)
    Knee Aperture
    On / OffTurns the knee aperture compensation function on/off.
    Knee Aperture Level
    –99 to +99 (±0)Adjusts the knee aperture level.
    Limit
    –99 to +99 (±0)Adjusts both the white and black detail limiter.
    White Limit
    –99 to +99 (±0)Adjusts the white detail limiter.
    Black Limit
    –99 to +99 (±0)Adjusts the black detail limiter.
    V Black Limit
    –99 to +99 (±0)Adjusts the black V detail limiter.
    V Detail Creation
    NAM / Y / G / G+RSelects the source signal to generate the V detail signal.
    NAM: Highest level signal of V detail signal that is generated 
    by R signal, G signal, or B signal.
    Y: Y signal
    G: G signal
    G+R: Synthesized signal from G and R signal with a same 
    ratio.
    ApertureSetting the 
    aperture 
    compensationSetting
    On / OffTurns the aperture compensation function on/off.
    Level
    –99 to +99 (±0)Adjusts the aperture level.
    Paint
     Menu itemsSub items and setting valuesContents 
    						
    All Sony manuals Comments (0)

    Related Manuals for Sony Pmv F5 Manual