Page 11
— 11 — KV-27FS100L/29FS100L The following adjustments should be made when a complete realignment is required or a new picture tube is installed. These adjustments should be performed with rated power supply voltage unless otherwise noted. Set the controls as follows unless otherwise noted: VIDEO MODE: Standard PICTURE CONTROL: Normal BRIGHTNESS CONTROL: Normal SECTION 2: SET-UP ADJUSTMENTS Perform the adjustments in order as follows: 1. Beam Landing 2. Convergence 3. Focus 4. Screen (G2) 5....
Page 12
— 12 — KV-27FS100L/29FS100L 2-2. CONVERGENCE Before starting convergence adjustments: 1 Perform FOCUS, VLIN and VSIZE adjustments. 2. Set BRIGHTNESS control to minimum. 3. Feed in dot pattern. VERTICAL STATIC CONVERGENCE 1. Adjust V. STAT magnet to converge red, green and blue dots in the center of the screen. 2. Tilt the V. STAT magnet and adjust static convergence to open or close the V. STAT magnet. When the V. STAT magnet is moved in the direction of arrow a and b, red, green, and blue dots...
Page 13
— 13 — KV-27FS100L/29FS100L DYNAMIC CONVERGENCE ADJUSTMENT Before performing this adjustment, perform Horizontal and Vertical Static Convergence Adjustment. 1. Slightly loosen deflection yoke screw. 2. Remove deflection yoke spacers. 3. Move the deflection yoke for best convergence as shown below: B GRG BR GB R R R G B GB G B R BGRGB GBR R G BG G B RB RR 4. Tighten the deflection yoke screw. 5. Install the deflection yoke spacers. TLH PLATE ADJUSTMENT 1. Input crosshatch pattern. 2. Adjust...
Page 14
— 14 — KV-27FS100L/29FS100L 2-4. SCREEN (G2) 1. Input a dot pattern. 2. Set the PICTURE and BRIGHTNESS controls at minimum and COLOR control at normal. 3. Adjust SBRT, GCUT, BCUT in service mode with an oscilloscope as shown below so that voltages on the red, green, and blue cathodes are 160 ± 2VDC. Pedestal 160 – 2VDC Ground ± 4. Observe the screen and adjust SCREEN (G2) VR in FBT to obtain the faintly visible background of dot signal. 2-5. METHOD OF SETTING THE SERVICE ADJUSTMENT MODE SERVICE...
Page 15
— 15 — KV-27FS100L/29FS100L HOLD-DOWN READJUSTMENT If the setting indicated in Step 2 of Hold-Down Operation Confi rmation cannot be met, readjustment should be performed by altering the resistance value of R564 component marked with X. + IABL ABL T585 FBT range - amPmeter 3.0 mA DC A 3-2. B+ VOLTAGE CONFIRMATION AND ADJUSTMENT Note: The following adjustments should always be performed when replacing the following components, which are marked with Y on the schematic diagram on the A Board: A...
Page 16
— 16 — KV-27FS100L/29FS100L Q590 T505 S006 S002 S003 S004 D612D613 RY601 D633 C676D632 PH602 D607 C643D610D609 D618D617 D602R505 C624 C505 C506 D598 C582R603S005 Q601Q600 IC602 L588 C523 Q522 CN401 IC565 IC400 Q650 IC402 IC545 IC561 S001 D005 VDR600 C601 D410 X301 R634 RY501 RY600 L508 D559 HS603 L513 L511 HS522 C525 L525D526 C513 D006 L516 C514 D545 D566 D525 L008 L582 C526 C511 Q008 IC002IC404 Q573 Q006 IC603 Q004 Q005 IC005 C512 Q608 D500 HS615D615 C618 CN515 IC401 R324 R042 R044 R093 R309...
Page 17
— 17 — KV-27FS100L/29FS100L 4-1. SETTING THE SERVICE ADJUSTMENT MODE 1. Standby mode (Power off). 2. Press the following buttons on the remote commander within a second of each other: Display Channel 5 Sound Volumne + Power SERVICE ADJUSTMENT MODE ON 1. The CRT displays the item being adjusted. DEF NTSC 1 NVM OK M65582AMF-101FPZ0 Signal Type Display Item #Category Item Data 41 Display Item H SIZE 2. Press 1 or 4 on the Remote Commander to select the item. 3. Press 3...
Page 18
— 18 — KV-27FS100L/29FS100L ADJUSTMENT ITEMS (1 OF 8) Device "DEF"Item# OSD DETAILRange (HEX) Initial Data 1 HSIZ H SIZE (EW DC) : YUV OFFSET 00-3F 41 2 HPOS H POSITION : YUV OFFSET 00-3F31 3 VSIZ V RAMP SIZE : YUV OFFSET 00-3F31 4 VPOS V POSITION (RAMP DC)not useful : YUV OFFSET 00-3F 35 5 VLIN V LINEARITY 00-3F 28 6 SCOR S CORRECTION 00-3F 45 7 VBOW BOW 00-3F 36 8 VANG ANGLE 00-3F 44 9 TRAP EW TRAPESIUM 00-3F 29 10 PAMP EW PIN 00-3F 47 11 UPIN UPPER PIN 00-3F 31 12 LPIN LOWER PIN 00-3F 29 13...
Page 19
— 19 — KV-27FS100L/29FS100L ADJUSTMENT ITEMS (2 OF 8) Device "VP1"Item# OSD DETAILRange (HEX) Initial Data 1 RDRV R DRIVE 00-7F 64/YUV:64 2 GDRV G DRIVE when Color Tem p. is "Cool" and "Neutral" 00-7F 45/YUV:47 3 BDRV B DRIVE when Color Temp. is "Cool" and "Neutral" 00-7F 59/YUV:62 4 RCUT HARDWARE AKB(R) CMP DATA 00-3FF 120/YUV:120 5 GCUT HARDWARE AKB(G) CMP DATA 00-3FF 68/YUV:67 6 BCUT HARDWARE AKB(B) CMP DATA 00-3FF 51/YUV:49 7 SCON SUB CONTRAST LEVEL 00-1F23 8...
Page 20
— 20 — KV-27FS100L/29FS100L ADJUSTMENT ITEMS (3 OF 8) Device "VP2"Item# OSD DETAILRange (HEX) Initial Data 1 VMOF VM LEVEL at "Off" Setting 00-0F 02 2 VMLO VM LEVEL at "Low" Settin g00-0F 04 3 VMHI VM LEVEL at "Hi gh" Setting00-0F 06 4 VMDL VM DELA Y00-0F 07 5 VMPL VM PORALITY 00-01 00 6 VMWD VM WIDTH 00-03 01 7 VMCL VM CORING LEVEL 00-0F 00 8 VMMX VM LIMITER LEVEL 00-0F 15 9 CKLV COLOR KILLER VTH 00-7F 01/YUV:00 10 CKON FORCE KILLER 00-0100 11 ALFA ADAPTIVE DET...