System data
Caracas DeskNur für den internen Gebrauch
 A31003-E1320-S100-4-7620
1-2Service Manual
Item code numbers
Table 1-1 Overview of item code numbers 
Designation Item code number Notes
Caracas Desk S97238-U3008-X200-* incl. V24 printer cable, AT 
modem adapter 
and V.24 Hicom cable
without plug-in PSU
Plug-in PSU C97280-Z3002-C8(IM)
C97280-Z3002-C9(GBR)
C97280-Z3002-
C10(AUS)12 volts
V.24 printer cable S97238-Z3008-X1-1 25-pin SubD
AT modem adapter C97334-Z3012-C2 25-pin SubD  9-pin 
SubD for...

Page 12

System data
A31003-E1320-S100-4-7620
Service Manual
1-3
Nur für den internen GebrauchCaracas Desk
 
Table 1-2 AT modem adapter pin assignment 
DB9 DB25
18
23
32
420
57
66
74
85
922 

Page 13

System data
Caracas DeskNur für den internen Gebrauch
 A31003-E1320-S100-4-7620
1-4Service Manual 

Page 14

A31003-E1320-S100-4-7620 
Service Manual
2-1
Nur für den internen GebrauchInstallation
2 Installation
Introduction
This chapter contains information on installing Caracas Desk at Hicom 100 E, Hicom 
150E 2.2, Hicom 150 E OfficeCom and OfficePoint systems.
Installation sequence
Note
V.24 line lengths (10m in each case) must be observed, see Figure 1-1.
Danger
Installation must be performed by authorised technical personnel only. 
Installation activity
1. Insert the polarised lithium battery in the module...

Page 15

InstallationNur für den internen Gebrauch
 A31003-E1320-S100-4-7620
2-2Service Manual
Caracas Desk wall mounting
Figure 2-1 Wall mounting and ports
Slots in
rear of 
housing
12345 Por ts:
Ports:
1 = V.24 cable to the printer
2 = V.24 cable to Hicom*
3 = Plug-in power supply unit
4 = Reception telephone
5 = 1st Hicom UP0/E interface
* V.24-adapter cable (2m) + accompanying 
V.24 cable (8m) or 
Hicom 150E 2.2/OfficeCom/ Office Point 
V.24 cable
Housing closed.
Hinged cover open. 

Page 16

A31003-E1320-S100-4-7620
Service Manual
3-1
Putting into service with Hicom 100 E, Hicom 150 E 2.2, Hicom 150 E Office Com and Office Po
Nur für den internen GebrauchPutting into service
3 Putting into service
3.1 Putting into service with Hicom 100 E, Hicom 150 E 2.2, Hicom 150 E 
Office Com and Office Point
Prerequisite
lThe UP0/E interface to the system must be connected to the 1st or 2nd Hicom 
U
P0/E port (the port must be authorised for system administration).
lAt least one add-on device must be...

Page 17

Putting into service with Hicom 100 E, Hicom 150 E 2.2, Hicom 150 E Office Com and Office 
Putting into serviceNur für den internen Gebrauch
 A31003-E1320-S100-4-7620
3-2Service Manual
Note
Only use the original plug-in power supply unit.
ProcedureTable 3-1 Checksum error list 
No. Checksum error
1 Roomlist
2 Alarmlist
4 Chargelist 
8 Calldetails
16 Historyfile
32 Configuration
64 Lookup Table
128 Charge Counter
256 Persistent State
512 Persistence Pattern
1024 CCM Base
Step Activity
1. Connect the V.24...

Page 18

A31003-E1320-S100-4-7620 
Service Manual
4-1
Loading new firmware in Caracas Desk
Nur für den internen GebrauchBasic settings
4 Basic settings
Note
The basic settings are password-protected.
Password: 
51695 (cannot be changed!).
The password should not be revealed to customers!
4.1 Loading new firmware in Caracas Desk
lSelect the *.fls file in Assistant for Caracas Desk and confirm the upload opera-
tion.
lSelect the menu item Settings/Basic settings/Load SW? and confirm. 
The reception telephone is not...

Page 19

Basic settings for connection to Hicom 100 E
Basic settingsNur für den internen Gebrauch
 A31003-E1320-S100-4-7620
4-2Service Manual
4.4 Basic settings for connection to Hicom 100 E
4.4.1 Setting the extension number plan in Hicom
As of Caracas Desk Rel. 2.0, the extension numbers can differ from the room num-
bers. The extension numbers in Hicom must correspond to the extension numbers 
set in Caracas Desk.
The extension numbers can be assigned in three manners.
1. Using Assistant L (fbzadmin.exe):...

Page 20

Basic settings for connection to Hicom 100 E
A31003-E1320-S100-4-7620
Service Manual
4-3
Nur für den internen GebrauchBasic settings
4.4.3 Extension settings in Caracas Desk
lLoad the current extension numbers to Caracas Desk via the Settings/Basic set-
tings/Read customer data menu.
lOnce the numbers have been successfully loaded (indicated by flashing Alarm 
LED), select the menu item Settings/Basic settings/Extensions.
lSet the extension types and, if necessary, the extension numbers. Extensions...