Page 51
47 Useful Features Note Input screen for keycode To cancel the keycode that you have already set •Press R on the projector for four times in steps 4 and 5 above. When the System Lock is set•When System Lock is set, the keycode input screen appears after the power is turned on. When it appears, enter the right keycode to start projection. Enter the same keycode in “Re- confirm”. System Lock–––– 5 Locking the Operation Buttons on the Projector Use this function to lock the operation buttons on the...
Page 52
48 Troubleshooting with the “Help” Menu Utilizing the “Help” Menu Functions This function advises you to solve the problems during usage. •You can adjust the items with check marks (✔). •The items in the “Help” menu change, de- pending on the input signal or setting that you have selected. •If the problem is not solved, refer to “Troubleshooting” (see pages 63 and 64). •When selecting “sRGB” in “Picture Mode”, the item “Color is faded or poor” is not displayed. This means you cannot change input signal...
Page 53
49 Appendix Cleaning the lens■Use a commercially available blower or lens cleaning paper (for glasses and camera lenses) for cleaning the lens. Do not use any liquid type cleaning agents, as they may wear off the coating film on the surface of the lens. ■As the surface of the lens can easily get damaged, be careful not to scrape or hit the lens. Cleaning the exhaust and intake vents■Use a vacuum cleaner to clean dust from the exhaust vent and the intake vent. Cleaning the projector■Ensure that you have...
Page 54
50 Maintenance Indicators About the lamp indicator ■When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be displayed on the screen. When the percentage becomes 0%, it will change to (red), the lamp will automatically turn off and then the projector will automatically enter standby mode. At this time, the lamp indicator will illuminate in red. ■If you try to turn on the projector a fourth time without replacing the lamp, the projector will not turn on. About the...
Page 55
51 Appendix •If the temperature warning indicator illuminates, and the projector enters standby mode, follow the possible solutions above and then wait until the projector has cooled down completely before plug- ging in the power cord and turning the power back on. (At least 10 minutes.) •If the power is turned off for a brief moment due to power outage or some other cause while using the projector, and the power supply recovers immediately after that, the lamp indicator will illumi- nate in red and the...
Page 56
52 Regarding the Lamp Lamp■It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes 5% or less, or when you notice a significant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display. (See page 47.) ■Purchase a replacement lamp of type AN-F212LP from your place of purchase, nearest Sharp Authorized Projector Dealer or Service Center. Caution Concerning the Lamp■This projector utilizes a pressurized...
Page 57
53 Appendix Removing and Installing the Lamp Unit •Do not touch the glass surface of the lamp unit or the inside of the projector. •To avoid injury to yourself and damage to the lamp, make sure you carefully follow the steps below. •Do not loosen other screws except for the lamp unit cover and lamp unit. Press STANDBY/ON on the projec- tor or STANDBY on the remote control to put the projector into standby mode. •Wait until the cooling fan stops. Warning! •Do not remove the lamp unit from the projec- tor...
Page 58
54 Remove the lamp unit.•Loosen the securing screws from the lamp unit. Hold the lamp unit and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. Insert the new lamp unit.•Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. Replace the lamp unit cover.•Align the tab on the lamp unit cover (1) and place it while pressing the tab (2) to close it....
Page 59
55 Appendix COMPUTER/COMPONENT input and COMPUTER/COMPONENT output Terminals : mini D- sub 15 pin female connector COMPUTER Input/Output Pin No. Signal 1. Video input (red) 2. Video input (green/sync on green) 3. Video input (blue) 4. Not connected 5. Not connected 6. Earth (red) 7. Earth (green/sync on green) 8. Earth (blue) 9. Not connected 10. GND 11. Not connected 12. Bi-directional data 13. Horizontal sync signal: TTL level 14. Vertical sync signal: TTL level 15. Data...
Page 60
56 RS-232C Terminal : mini DIN 9 pin female connector RD SD SG RS CS Signal Name 8 9 6 5 2143 7Pin No. 1. 2. 3. 4. 5. 6. 7. 8. 9.I/O Reference Not connected Connected to internal circuit Connected to internal circuit Not connected Connected to internal circuit Not connected Connected to CS in internal circuit Connected to RS in internal circuit Not connected Receive Data Send Data Signal Ground Request to Send Clear to SendInput Output RS-232C Terminal : D-sub 9 pin male connector of the DIN-D-sub...