Page 1
R-1480 R-1481 R-1482 In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti- fier Assembly, High Voltage Harness etc..) TABLE...
Page 2
R-1480 R-1481 R-1482 PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of...
Page 3
1 R-1480 R-1481 R-1482 WARNING TO SERVICE PERSONNEL Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disconnect the power supply cord , and then remove...
Page 4
2 R-1480 R-1481 R-1482 MICROWAVE MEASUREMENT PROCEDURE A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm 2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2) Safety interlock switches Primary interlock relay...
Page 5
3 R-1480 R-1481 R-1482 SHARP ELECTRONICS CORPORATION SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL OVER THE RANGE MICROWAVE OVEN R-1480 / R-1481 / R-1482 FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP OVER THE RANGE MICROWAVE OVEN, R-1480, R-1481, R-1482. It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory...
Page 6
4 R-1480 R-1481 R-1482 ITEM DESCRIPTION Power Requirements 120 Volts / 14.3 Amperes 60 Hertz Single phase, 3 wire grounded Power Output 950 watts (IEC-705 TEST PROCEDURE) Operating frequency of 2450MHz Convection Power Output 1700 watts Case Dimensions Width 29-15/16 Height 16-3/8 Depth 15- 1/4 (Not including the door handle) Cooking Cavity Dimensions Width 20-1/4 Height 8-3/16 1.4 Cubic Feet Depth 14-1/2 Hood lamp 2 bulbs, 30W x 2, Incandescent light bulbs Hood fan Approx. 300 C.F.M. Control...
Page 7
5 R-1480 R-1481 R-1482 Electrical Requirements The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG. The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more branch circuit, using a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood system mounting location. OVEN DIAGRAM 1. Oven door with see-through window. 2. Door hinges. 3....
Page 8
6 R-1480 R-1481 R-1482 MIX CONV COOK LBS KGTURNTABLEOFF HELP CONTROL PANEL OPERATION DESCRIPTION OF OPERATING SEQUENCE The following is a description of component functions during oven operation. OFF CONDITION Closing the door activates the door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1). 1. The display will show , , , ,, , , and .To set...
Page 9
7 R-1480 R-1481 R-1482 RELAY CONNECTED COMPONENTS RY1 Oven lamp / Fan motor / Stirrer motor RY2 Power transformer RY3 Turntable motor RY4 Hood fan motor 2. 120 volts A.C. is supplied to the primary winding of the power transformer and is converted to about 3.3 volts A.C. output on the filament winding, and approximately 2000 volts A.C. on the high voltage winding. 3. The filament winding voltage heats the magnetron filament and the H.V. winding voltage is sent to a voltage doubler circuit. 4. The...
Page 10
8 R-1480 R-1481 R-1482 2. HORIZONTAL VENTING The air handing is the same as VERTICAL VENTING except that the final air discharge is directed horizontally out from the top rear of the oven into the customers vent system. _: AIR FLOW 3. RE-CIRCULATION (INSIDE VENTING) The air handing is the same as VERTICAL VENTING except that the final air discharge is directed horizontally through the upper front of the oven into the kitchen. IN this case, the accessory charcoal filter RK-230 must be provided to filter...