Page 1

R-1480
R-1481
R-1482
In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
fier Assembly,  High Voltage Harness etc..)
TABLE...

Page 2

R-1480
R-1481
R-1482
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of...

Page 3

1
R-1480
R-1481
R-1482
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with
following parts 
 may result in a severe, possibly
fatal, electrical shock.
(Example)
High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem-
bly,  High Voltage Harness etc..
Read the Service Manual carefully and follow all
instructions.
Before Servicing
1. Disconnect the power supply cord ,  and  then
remove...

Page 4

2
R-1480
R-1481
R-1482
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven
should not exceed 1mW/cm
2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition
by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external
surface of the oven.
2) Safety interlock switches Primary interlock relay...

Page 5

3
R-1480
R-1481
R-1482
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
OVER THE RANGE
MICROWAVE OVEN
R-1480 / R-1481 / R-1482
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp.
Service Personnel with Operation and Service Information for the
SHARP OVER THE RANGE  MICROWAVE OVEN, R-1480, R-1481,
R-1482.
It is recommended that service personnel carefully study the entire
text of this manual so that they will be qualified to render satisfactory...

Page 6

4
R-1480
R-1481
R-1482
ITEM DESCRIPTION
Power Requirements 120 Volts / 14.3 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output 950 watts (IEC-705 TEST PROCEDURE)
Operating frequency of 2450MHz
Convection Power Output 1700 watts
Case Dimensions Width 29-15/16
Height 16-3/8
Depth  15- 1/4 (Not including the door handle)
Cooking Cavity Dimensions Width 20-1/4
Height 8-3/16
1.4 Cubic Feet Depth  14-1/2
Hood lamp 2 bulbs, 30W x 2,  Incandescent light bulbs
Hood fan Approx. 300 C.F.M.
Control...

Page 7

5
R-1480
R-1481
R-1482
Electrical Requirements
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE
GROUNDING PIN FROM THE PLUG.
The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more branch circuit, using
a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood
system mounting location.
OVEN DIAGRAM
1. Oven door with see-through window.
2. Door hinges.
3....

Page 8

6
R-1480
R-1481
R-1482
MIX CONV COOK LBS KGTURNTABLEOFF HELP
 CONTROL PANEL
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions during
oven operation.
OFF CONDITION
Closing the door activates the door sensing switch and
secondary interlock switch. (In this condition, the monitor
switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the
control unit. (Figure O-1).
1. The display will show , , ,
,, , ,
  and                .To set...

Page 9

7
R-1480
R-1481
R-1482
RELAY CONNECTED COMPONENTS
RY1 Oven lamp / Fan motor / Stirrer motor
RY2 Power transformer
RY3 Turntable motor
RY4 Hood fan motor
2. 120 volts A.C. is supplied to the primary winding of the
power transformer and is converted to about 3.3 volts
A.C. output on the filament winding, and approximately
2000 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron
filament and the H.V. winding voltage is sent to a voltage
doubler circuit.
4. The...

Page 10

8
R-1480
R-1481
R-1482
2. HORIZONTAL VENTING
The air handing is the same as VERTICAL VENTING
except that the final air discharge is directed horizontally
out from the top rear of the oven into the customers vent
system.
_: AIR FLOW
3. RE-CIRCULATION (INSIDE VENTING)
The air handing is the same as VERTICAL VENTING
except that the final air discharge is directed horizontally
through  the upper front of the oven into the kitchen. IN
this case, the accessory charcoal filter RK-230 must be
provided to filter...