Page 11
9 R-1480 R-1481 R-1482 SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. COOKING TIME PROGRAMMED 3. VARIABLE COOKING CONTROL HIGH 4. START PAD TOUCHED Figure O-2. Oven Schematic-Cooking ConditionFigure O-1. Oven Schematic-Off Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY MAGNETRON TEMPERATURE FUSE FUSE 20A TURNTABLE MOTOR FAN MOTOR STIRRER MOTOR MAGNETRON OVEN LAMP MONITOR SWITCHBLK WHT POWER TRANSFORMER HIGH VOLTAGE CAPACITOR 0.94µF HIGH VOLTAGE...
Page 12
10 R-1480 R-1481 R-1482 DESCRIPTION AND FUNCTION OF COMPONENTS DOOR OPEN MECHANISM The door is opened by pulling the door handle, refer to the Figure D-1.CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE DOOR SENSING SWITCH, PRIMARY INTERLOCK RELAY (RY2), SEC- ONDARY INTERLOCK SWITCH AND MONI- TOR SWITCH FOR PROPER OPERATION. (REFER TO CHAPTER TEST PROCEDURE). NOTE: MONITOR FUSE AND SWITCH ARE REPLACED AS AN ASSEMBLY TEMPERATURE FUSE (MG) The temperature fuse located near the waveguide is designed...
Page 13
11 R-1480 R-1481 R-1482 TROUBLESHOOTING GUIDE Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected. When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the Test Procedure section. IMPORTANT:If the oven becomes inoperative because of a...
Page 14
12 R-1480 R-1481 R-1482 CK = Check / RE = Replace POSSIBLE CASE AND DEFECTIVE PARTS PROBLEMTEST PROCEDURE CONDITIONOFF CONDITION IDLE CONDITIONMICROWAVE COOKING CONDITION Home fuse blows when power cord is plugged into wall receptacle. Monitor fuse blows when power cord is plugged into wall receptacle. Display does not illuminate when power cord is first plugged into wall receptacle. Display does not operate properly when STOP/CLEAR key is touched. (The time of day should appear on...
Page 15
13 R-1480 R-1481 R-1482 BPOWER TRANSFORMER TEST TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm. 5. To test for a shorted magnetron, connect the ohmmeter leads between the magnetron filament leads...
Page 16
14 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the terminals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indicate continuity for a short time...
Page 17
15 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Check the monitor switch operation by using the...
Page 18
16 R-1480 R-1481 R-1482 IBLOWN MONITOR FUSE TEST TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary interlock switch and monitor switch according to the TEST PROCEDURE for those switches before replacing the blown monitor fuse. CAUTION: BEFORE REPLACING A BLOWN MONITOR...
Page 19
17 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST Resistance between; BLU (1) AND YLW (4) = 0W(Shorted) BLK (2) AND YLW (4) = 32W BLU (1) AND BLK (2) = 32W BLK (2) AND WHT (3) = 20W WHT (3) AND RED (5) = 45W 123 45 BLU BLK WHT YLW RED 6-PIN CONNECTOR OF HOOD FAN MOTOR 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. LTOUCH...
Page 20
18 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 7) Reconnect the power supply cord after the outer case is installed. 8) Run the oven and check all functions. 2. Control Unit. The following symptoms indicate a defective control unit. Before replacing the control unit, perform the Key unit test (Procedure M) to determine if control unit is faulty. 2-1 In connection with pads. a) When touching the pads, a certain group of pads do not produce a signal. b) When touching the pads,...