    							9
    R-1480
    R-1481
    R-1482
    SCHEMATIC
    NOTE: CONDITION OF OVEN
    1. DOOR CLOSED
    2. COOKING TIME PROGRAMMED
    3. VARIABLE COOKING CONTROL HIGH
    4. START PAD TOUCHED
    Figure O-2. Oven Schematic-Cooking ConditionFigure O-1. Oven Schematic-Off Condition
    SCHEMATIC
    NOTE: CONDITION OF OVEN
    1. DOOR CLOSED
    2.  CLOCK APPEARS ON DISPLAY
    MAGNETRON 
    TEMPERATURE FUSE
    FUSE 
    20A
    TURNTABLE
    MOTOR
    FAN
    MOTOR
    STIRRER
    MOTOR
    MAGNETRON OVEN LAMP
    MONITOR
    SWITCHBLK WHT
    POWER
    TRANSFORMER
    HIGH VOLTAGE
    CAPACITOR
    0.94µF
    HIGH VOLTAGE
    RECTIFIER  COM. N.O.
    COM. CONTROL UNIT
    GND GRN
    HOOD
    MOTORB7
    B5
    B3
    B1High
    Low
    A1 A3 B9 A7 A5 N.O.E1
    E2
    DOOR
    SENSING
    SWITCH
    SECONDARY
    INTERLOCK
    SWITCH 120 V AC.
    60 Hz 
    HOOD
    LAMP
    HL HL
    RY3 RY1
    RY2
    PRIMARY
    INTERLOCK 
    RELAY
    FMSTM
    OL
    TTM
    HOOD FAN
    THERMAL
    CUT OUT
    HOOD
    CAPACITORRY4
    RY5
    N.C.
    CAVITY 
    THERMAL CUT-OUT
    SSR
    MAGNETRON 
    TEMPERATURE FUSE
    FUSE 
    20A
    TURNTABLE
    MOTOR
    FAN
    MOTOR
    STIRRER
    MOTOR
    MAGNETRON OVEN LAMP
    MONITOR
    SWITCHBLK WHT
    POWER
    TRANSFORMER
    HIGH VOLTAGE
    CAPACITOR
    0.94µF
    HIGH VOLTAGE
    RECTIFIER  COM. N.O.
    COM. CONTROL UNIT
    GND GRN
    HOOD
    MOTORB7
    B5
    B3
    B1High
    Low
    A1 A3 B9 A7 A5 N.O.E1
    E2
    DOOR
    SENSING
    SWITCH
    SECONDARY
    INTERLOCK
    SWITCH 120 V AC.
    60 Hz 
    HOOD
    LAMP
    HL HL
    RY3 RY1
    RY2
    PRIMARY
    INTERLOCK 
    RELAY
    FMSTM
    OL
    TTM
    HOOD FAN
    THERMAL
    CUT OUT
    HOOD
    CAPACITORRY4
    RY5
    N.C.
    CAVITY 
    THERMAL CUT-OUT
    SSR 
    						
    							10
    R-1480
    R-1481
    R-1482
    DESCRIPTION AND FUNCTION OF COMPONENTS
    DOOR OPEN MECHANISM
    The door is opened by pulling the door handle, refer to the
    Figure D-1.CAUTION: BEFORE REPLACING A BLOWN MONITOR
    FUSE TEST THE DOOR SENSING SWITCH,
    PRIMARY INTERLOCK RELAY (RY2), SEC-
    ONDARY INTERLOCK SWITCH AND MONI-
    TOR SWITCH FOR PROPER OPERATION.
    (REFER TO CHAPTER TEST PROCEDURE).
    NOTE: MONITOR FUSE AND SWITCH ARE REPLACED
    AS AN ASSEMBLY
    TEMPERATURE FUSE (MG)
    The temperature fuse located near the waveguide  is
    designed to prevent damage to the magnetron if an over
    heated condition develops in the tube due to cooling fan
    failure, obstructed air guide, dirty or blocked air intake, etc.
    Under normal operation, the temperature fuse remains
    closed. However, the temperature fuse will open at 302ûF
    (150ûC) causing the oven to shut down.
    THERMAL CUT-OUT (HOOD )
    This thermal cut-out located on the right base plate. It is
    designed to automatically turn on the hood fan motor
    whenever the hot air rising from the conventional range
    below causes the temperature at the thermal cut-out to rise
    to 140ûF (60ûC) or higher, thus removing this hot air from
    around microwave oven. When the temperature around the
    thermal cut-out drops to 113ûF (45ûC) or lower, the thermal
    cut-out shuts off the hood fan motor.
    THERMAL CUT-OUT (CAVITY )
    This thermal cut-out is located on the top of the oven cavity.
    It is designed to prevent damage to the oven unit if the food
    in the oven catches fire due to overheating produced by
    improper setting of cooking time or failure of control unit.
    Under normal operation, the thermal cut-out  remains closed.
    However, the thermal cut-out will open at 293ûF (145ûC)
    causing the oven to shut down.
    TURNTABLE MOTOR
    The turntable motor rotates the turntable located on the
    bottom of the oven cavity, so that the foods on the turntable
    cook evenly during cooking. Turntable will turn in either
    direction. The turntable motor can be turned off by touching
    TURNTABLE ON/OFF pad.
    COOLING FAN MOTOR
    The cooling fan motor drives a blade which draws external
    cool air. This cool air is directed through the air vanes
    surrounding the magnetron and cools the magnetron. This air
    is channelled through the oven cavity to remove steam and
    vapors given off from the heating foods. It is then exhausted
    through the exhausting air vents at the oven cavity.
    HOOD FAN MOTOR
    The hood fan motor is a two-speed, single-phase, double
    pole induction type, requiring a hood fan capacitor. It is
    located outside the upper rear part of the oven cavity, is to
    remove, from around the oven, hot air rising from the
    conventional electric or gas range over which it is installed. Figure D-1. Door Open Mechanism
    DOOR SENSING AND SECONDARY INTERLOCK
    SWITCHES
    The secondary interlock switch is mounted in the lower
    position of the latch hook and the door sensing switch in the
    primary interlock system is mounted in the upper position of
    the latch hook. They are activated by the latch heads on the
    door. When the door is opened, the switches interrupt the
    circuit to all components. A cook cycle cannot take place
    until the door is firmly closed thereby activating both inter-
    lock switches. The primary interlock system consists of the
    door sensing switch and primary interlock relay located on
    the control circuit board.
    MONITOR SWITCH
    The monitor switch is activated (the contacts opened) by the
    latch head on the door while the door is closed. The switch
    is intended to render the oven inoperative by means of
    blowing the monitor fuse when the contacts of the primary
    interlock relay (RY2) and secondary interlock switch fail to
    open when the door is opened.
    Functions:
    1. When the door is opened, the monitor switch contact
    close (to the ON condition) due to their being normally
    closed. At this time the primary interlock relay (RY2) and
    secondary interlock switch are in the OFF condition
    (contacts open) due to their being normally open contact
    switches. And the contacts of relay (RY1) are in the ON
    condition (contacts close).
    2. As the door goes to a closed position, the monitor switch
    contacts are first opened and then the door sensing
    switch and the secondary interlock switch contacts close.
    (On opening the door, each of these switches operate
    inversely.)
    3. If the door is opened, and the primary interlock relay
    (RY2) and secondary interlock switch contacts fail to
    open, the monitor fuse blows simultaneously with closing
    of the monitor switch contacts.
    Secondary
    Interlock
    Switch
    Monitor
    Switch
    Monitor
    Fuse
    Door
    Sensing
    Switch
    Latch
    Hook
    DoorLatch
    Heads 
    						
    							11
    R-1480
    R-1481
    R-1482
    TROUBLESHOOTING GUIDE
    Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.
    When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many
    of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which
    will be found in the Test Procedure section.
    IMPORTANT:If the oven becomes inoperative because of a blown  monitor fuse, check the monitor switch, relay (RY1)
    primary interlock relay (RY2), door sensing switch and secondary interlock switch before replacing the
    monitor fuse. If  monitor fuse is replaced, the monitor switch must also be replaced. Use part FFS-BA016/
    KiT as an assembly.
    IMPORTANT:Whenever troubleshooting is performed with the power supply cord disconnected. It may in, some cases,
    be necessary to connect the power supply cord after the outer case has been removed, in this event,
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Disconnect the leads to the primary of the power transformer.
    5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.
    6. After that procedure, reconnect the power supply cord.
    When the testing is completed
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Reconnect the leads to the primary of the power transformer.
    5. Reinstall the outer case (cabinet).
    6. Reconnect the power supply cord after the outer case is installed.
    7. Run the oven and check all functions.
    This air is then expelled either vertically or horizontally
    through the customer supplied duct system, or discharged
    back into the kitchen.
    STIRRER MOTOR
    The stirrer motor drives the stirrer fan to stir the microwave
    radiation from the waveguide.
    HOOD LAMP
    The hood lamps are mounted at the hood lamp angle on the
    base cover. The hood lamps can be turned off and on by
    touching the WORK LIGHT pad or the NIGHT LIGHT pad.
    And also the brightness can be varied to high or low by
    touching the WORK LIGHT pad or the NIGHT LIGHT pad. 
    						
    							12
    R-1480
    R-1481
    R-1482
    CK = Check / RE = Replace
    POSSIBLE CASE AND 
    DEFECTIVE PARTS
    PROBLEMTEST PROCEDURE
    CONDITIONOFF
    
    CONDITION
    IDLE
    
    CONDITIONMICROWAVE
    COOKING
    CONDITION
    
    Home fuse blows when power cord is plugged into wall receptacle.
      
    Monitor fuse blows when power cord is plugged into wall receptacle.
      
    Display does not illuminate when power cord is first plugged into wall 
    receptacle.
      
    Display does not operate properly when STOP/CLEAR key is touched. 
    (The time of day should appear on the display with beep sound during 
    normal condition.)
      
    Oven lamp does not light with door is opened.
      
    Hood fan motor operates when power cord is first plugged into wall 
    receptacle.
      
    Temperature of oven base seems more than 140˚F (60˚C) because of 
    operation of the range below. But hood fan motor does not turn on 
    automatically. (Normally, food fan motor should be operating at low 
    speed.)
      
    Hood lights do not turn on when WORK LIGHT pad or NIGHT LIGHT pad 
    is pressed.
      
    Hood fan motor does not rotate at all with touched FAN HI/LO pad.
      
    Speed of the hood fan motor does not change when the FAN HI/LO pad is 
    touched for this function.
      
    Oven lamp does not light in cook cycle. (But it does light when door is 
    opened.)
      
    Fan motor does not operate. (Oven lamp and turntable motor operate.)
      
    Turntable motor does not operate (Oven lamp lights and fan motor 
    operate.)
      
    Oven does not go into cook cycle when START pad is touched
      
    Oven seems to be operating but little or no heat is produced in oven load. 
    (Food incompletely cooked or not cooked at all at end of cook cycle.)
      
    Oven goes into a cook cycle but extremely uneven heating is produced in 
    oven load (food).
      
    Variable cooking does not operate properly except Cooking Power 10 (P-
    HI) mode.
      
    Function of COMPU DEFROST does not operate properly.
      
    Stirrer motor does not operate. (Other parts operate.)
      
    Oven goes into COMPU DEFROST but food is not defrosted well.
    
    
    
    
    	CK	 LOW VOLTAGE
    	CK	 NO POWER AT OUTLET
    	RE	 SHORTED IN POWER CORD
    	 CK	 OPENED OR SHORTED WIRING
    	CK	 HOOD MOTOR CAPACITOR
    	RE	 HOOD LAMP OR SOCKET
    	CK	 TURNTABLE OFF CONDITION
    	RE	 STIRRER MOTOR
    	RE	 TURNTABLE MOTOR
    	RE	 FAN MOTOR
    	RE	 OVEN LAMP OR SOCKET
    	 P	 FOIL PATERN ON P.W.B.
    	 O	 COMPU DEFROST
    	 N	 RELAY (RY-5)
    	 N	 RELAY (RY-4)
    	 N	 RELAY (RY-3)
    	 N	 RELAY (RY-2)
    	 N	 RELAY (RY-1)
    	 M	 KEY UNIT
    	 L	 CONTROL UNIT
    	 K	 HOOD FAN MOTOR 
    	 J	 HOOD HERMAL CUT-OUT 
    	 I	 MONITOR FUSE 
    	 H	 MONITOR SWITCH
    	G	PRIMARY INTERLOCK SYSTEM
    	 F	 SECONDARY INTERLOCK  SWITCH
    	
    	E	
    TEMPERATURE FUSE OR THERMAL CUT-OUT
    	 D	 HIGH VOLTAGE CAPACITOR
    	 C	 H.V. RECTIFIER 
    	 B	 POWER TRANSFORMER
    	 A	 MAGNETRON 
    						
    							13
    R-1480
    R-1481
    R-1482
    BPOWER TRANSFORMER TEST
    TEST PROCEDURES
    PROCEDURE
    LETTERCOMPONENT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check
    across the magnetron filament leads should indicate less than 1 ohm.
    5. To test for a shorted magnetron, connect the ohmmeter leads between the magnetron filament leads
    and chassis ground. This test should indicate an infinite resistance. If there is little or no resistance
    the magnetron is grounded and must be replaced.
    6. Reconnect all leads removed from components during testing.
    7. Reinstall the outer case (cabinet).
    8. Reconnect the power supply cord after the outer case is installed.
    9. Run the oven and check all functions.
    MICROWAVE OUTPUT POWER
    The following test procedure should be carried out with the microwave oven in a fully assembled
    condition (outer case fitted).
    HIGH VOLTAGES ARE PRESENT DURING THE COOK CYCLE, SO EXTREME CAUTION SHOULD
    BE OBSERVED.
    Power output of the magnetron can be measured by performing a water temperature rise test. This test
    should only be used if above tests do not indicate a faulty magnetron and there is no defect in the following
    components or wiring: silicon rectifier, high voltage capacitor and power transformer. This test will require
    a 16 ounce (453cc) measuring cup and an accurate mercury thermometer or thermocouple type
    temperature tester. For accurate results, the following procedure must be followed carefully:
    1. Fill the measuring cup with 16 oz. (453cc) of tap water and measure the temperature of the water with
    a thermometer or thermocouple temperature tester. Stir the thermometer or thermocouple through
    the water until the temperature stabilizes. Record the temperature of the water.
    2. Place the cup of water in the oven. Operate oven at POWER 10(HIGH) selecting more than 60
    seconds cook time. Allow the water to heat for 60 seconds, measuring with a stop watch, second hand
    of a watch or the digital read-out countdown.
    3. Remove the cup from the oven and again measure the temperature, making sure to stir the
    thermometer or thermocouple through the water until the maximum temperature is recorded.
    4. Subtract the cold water temperature from the hot water temperature. The normal result should be 27.7
    to 51.5ûF(15.4 to 28.6ûC) rise in temperature. If the water temperatures are accurately measured and
    tested for the required time period the test results will indicate if the magnetron tube has low power
    output (low rise in water temperature) which would extend cooking time or high power output (high
    rise in water temperature) which would reduce cooking time. Because cooking time can be adjusted
    to compensate for power output, the magnetron tube assembly should be replaced only if the water
    temperature rise test indicates a power output well beyond the normal limits. The test is only accurate
    if the power supply line voltage is 120 volts and the oven cavity is clean.
    AMAGNETRON ASSEMBLY TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Disconnect the primary input terminals and measure the resistance of the transformer with an
    ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of
    the primary coil should be less than 1 ohm and the resistance of the high voltage coil should be
    approximately 90 ohms; the resistance of the filament coil should be less than 1 ohm.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions. 
    						
    							14
    R-1480
    R-1481
    R-1482
    TEST PROCEDURES
    PROCEDURE
    LETTERCOMPONENT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads
    and check for short or open between the terminals using an ohmmeter.
    Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indicate
    continuity for a short time and should indicate an open circuit once the capacitor is charged. If the
    above is not the case, check the capacitor with an ohmmeter to see if it is shorted between either of
    the terminals and case. If it is shorted, replace the capacitor.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    DHIGH VOLTAGE CAPACITOR TEST
    ECAVITY THERMAL CUT-OUT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. A continuity check across the thermal cut-out terminals should indicate a closed circuit unless the
    temperature of the thermal cut-out reaches approximately 293ûF(145ûC).
    An open thermal cut-out indicates overheating of the oven, exchange the oven thermal cut-out and
    check inside of oven cavity and for improper setting of cooking time or operation of control unit. Check
    for restricted air flow through the vent holes of the oven cavity, especially the cooling fan and air guide.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
     MAGNETRON TEMPERATURE FUSE TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. A continuity check across the temperature fuse terminals should indicate a closed circuit. If the
    temperature of the magnetron reaches approximately 302ûF(150ûC), the temperature fuse opens. An
    open temperature fuse indicates overheating of the magnetron. Check for restricted air flow to the
    magnetron, especially the cooling fan air guide.
    5. Reconnect all leads removed from components during testing.
    CHIGH VOLTAGE RECTIFIER TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Isolate the rectifier from the circuit. Using the highest ohm scale of the meter, read the resistance
    across the terminals and observe, reverse the leads to the rectifier terminals and observe meter
    reading. If a short is indicated in both directions, or if an infinite resistance is read in both directions,
    the rectifier is probably defective and should be replaced.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    NOTE: Be sure to use an ohmmeter that will supply a forward bias voltage of more than 6.3 volts. (HIGH VOLTAGES ARE PRESENT AT THE HIGH VOLTAGE TERMINAL, SO DO NOT ATTEMPT TO
    MEASURE THE FILAMENT AND HIGH VOLTAGE.) 
    						
    							15
    R-1480
    R-1481
    R-1482
    TEST PROCEDURES
    PROCEDURE
    LETTERCOMPONENT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Before performing this test, make sure that the secondary interlock switch and the primary interlock
    relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead
    from the monitor switch (COM) terminal. Check the monitor switch operation by using the ohmmeter
    as follows. When the door is open, the meter should indicate a closed circuit. When the monitor switch
    actuator is pushed by a screw driver through the lower latch hole on the front plate of the oven cavity
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    CAUTION: IF THE THERMAL CUT-OUT OR TEMPERATURE FUSE INDICATES AN OPEN CIRCUIT
    AT ROOM TEMPERATURE, REPLACE THERMAL CUT-OUT OR TEMPERATURE FUSE.
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal
    of the switch. The meter should indicate an open circuit with the door open and a closed circuit with
    the door closed. If improper operation is indicated, replace the secondary interlock switch.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    FSECONDARY INTERLOCK SWITCH TEST
    HMONITOR SWITCH TEST
    GPRIMARY INTERLOCK SYSTEM TEST
    DOOR SENSING SWITCH
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal
    of the switch. The meter should indicate an open circuit with the door open and a closed circuit with
    the door closed. If improper operation is indicated, replace the door sensing switch.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the cooling
    fan motor, stirrer motor and oven light will be activated by RY1.
    PRIMARY INTERLOCK RELAY (RY2)
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay. Check the
    state of the relay contacts using a ohmmeter. The relay contacts should be open. If the relay contacts
    are closed, replace the circuit board entirely or the relay itself.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions. 
    						
    							16
    R-1480
    R-1481
    R-1482
    IBLOWN MONITOR FUSE TEST
    TEST PROCEDURES
    PROCEDURE
    LETTERCOMPONENT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary
    interlock switch and monitor switch according to the TEST PROCEDURE for those switches before
    replacing the blown monitor fuse.
    CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE PRIMARY INTERLOCK
    RELAY, SECONDARY INTERLOCK SWITCH, DOOR SENSING SWITCH AND MONITOR
    SWITCH FOR PROPER OPERATION.
    If the monitor fuse  is blown by improper switch operation, the monitor fuse and monitor switch must
    be replaced with monitor fuse and monitor switch assembly part number FFS-BA016/KiT, even if
    the monitor switch operates normally. The monitor fuse and monitor switch assembly is comprised
    of a 20 ampere fuse and switch.
    5. Reconnect all leads removed from components during testing.
    6. Re-install the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.with the door opened (in this condition the plunger of the monitor switch is pushed in), the meter should
    indicate an open circuit. If improper operation is indicated, the switch may be defective. After testing
    the monitor switch, reconnect the wire lead to the monitor switch (COM) terminal and check the
    continuity of the monitor circuit.
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after
    the outer case is installed.
    8. Run the oven and check all functions.
    Secondary
    Interlock
    SwitchMonitor
    Switch
    Screw Driver
    Ohmmeter
    Black 
    White/White
    JHOOD THERMAL CUT-OUT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. A continuity check across the thermal cut-out terminals should indicate an open circuit unless the
    temperature of the thermal cut-out reaches approximately 140ûF(60ûC) or more. At  that temperature,
    the contacts will close. The thermal cut-out opens automatically at approximately 113ûF(45ûC).
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    KHOOD FAN MOTOR TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. If the motor does not turn, touch the FAN HI / LO pad once (set hood fan motor power HIGH) and
    check voltage between pins 1 and 2 (Blue and Black wires) of the 6 pin connector. If 120 Volts
    appear and the hood capacitor is good, replace the hood fan assembly. If 120 Volts does not appear,
    check the motor circuit. The resistance values of motor terminals are as follows: 
    						
    							17
    R-1480
    R-1481
    R-1482
    TEST PROCEDURES
    PROCEDURE
    LETTERCOMPONENT TEST
    Resistance between;
    BLU (1) AND YLW (4) = 0W(Shorted)
    BLK (2) AND YLW (4) = 32W
    BLU (1) AND BLK (2) = 32W
    BLK (2) AND WHT (3) = 20W
    WHT (3) AND RED (5) = 45W
    123
    45 BLU BLK WHT
    YLW RED
    6-PIN CONNECTOR
    OF HOOD FAN MOTOR
    5. Reconnect all leads removed from components during testing.
    6. Reinstall the outer case (cabinet).
    7. Reconnect the power supply cord after the outer case is installed.
    8. Run the oven and check all functions.
    LTOUCH CONTROL PANEL ASSEMBLY TEST
    The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
    unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter
    and ohmmeter.
    In this service manual, the touch control panel assembly is divided into two units, Control Unit and Key
    Unit, and troubleshooting by unit replacement is described according to the symptoms indicated.
    Before testing,
    1) Disconnect the power supply cord, and then remove outer case. Refer to procedure of HOOD
    EXHAUST LOUVER REMOVAL, REMOVAL OF OVEN FROM WALL and OUTER CASE
    REMOVAL.
    2) Open the door and block it open.
    3) Discharge high voltage capacitor.
    4) Disconnect the leads to the primary of the power transformer.
    5) Ensure that these leads remain isolated from other components and oven chassis by using
    insulation tape.
    6) After that procedure, re-connect the power supply cord.
    1.  Key Unit.
    NOTE ;
    1) Disconnect the power supply cord, and then remove outer case.
    2) Open the door and block it open.
    3) Discharge high voltage capacitor.
    4) Check key unit ribbon connection before replacement.
    5) Reconnect all leads removed from components during testing.
    6) Re-install the outer case (cabinet).
    7) Reconnect the power supply cord after the outer case is installed.
    8) Run the oven and check all functions.
    The following symptoms indicate a defective key unit.
    a) When touching the pads, a certain pad produces no signal at all.
    b) When touching a number pad, two figures or more are displayed.
    c) When touching the pads, sometimes a pad produces no signal.
    If the key unit is defective.
    1) Disconnect the power supply cord, and then remove outer case.
    2) Open the door and block it open.
    3) Discharge high voltage capacitor.
    4) Replace the key unit.
    5) Reconnect all leads removed from components during testing.
    6) Re-install the outer case (cabinet).
    32 ½
    20 ½ 45 ½ HOOD FAN
    CAPACITORYLW
    REDBLU
    BLK1
    2
    3
    WHT
    4
    5 
    						
    							18
    R-1480
    R-1481
    R-1482
    TEST PROCEDURES
    PROCEDURE
    LETTERCOMPONENT TEST
    7) Reconnect the power supply cord after the outer case is installed.
    8) Run the oven and check all functions.
    2.  Control Unit.
    The following symptoms  indicate a defective control unit.  Before replacing the control unit, perform
    the Key unit test (Procedure M) to determine if control unit is faulty.
    2-1  In connection with pads.
    a) When touching the pads, a certain group of pads do not produce a signal.
    b) When touching the pads, no pads produce a signal.
    2-2  In connection with indicators
    a) At a certain digit, all or some segments do not light up.
    b) At a certain digit, brightness is low.
    c) Only one indicator does not light.
    d) The corresponding segments of all digits do not light up; or they continue to light up.
    e) Wrong figure appears.
    f) A certain group of indicators do not light up.
    g) The figure of all digits flicker.
    2-3  Other possible problems caused by defective control unit.
    a) Buzzer does not sound or continues to sound.
    b) Clock does not operate properly.
    c) Cooking is not possible.
    When testing is completed,
    1) Disconnect the power supply cord, and then remove outer case.
    2) Open the door and block it open.
    3) Discharge high voltage capacitor.
    4) Reconnect all leads removed from components during testing.
    5) Re-install the outer case (cabinet).
    6) Reconnect the power supply cord after the outer case is installed.
    7) Run the oven and check all functions.
    MKEY UNIT TEST
    1. Disconnect the power supply cord, and then remove outer case.
    2. Open the door and block it open.
    3. Discharge high voltage capacitor.
    4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
    is making good contact, verify that the door sensing switch (stop switch) operates properly; that is the
    contacts are closed when the door is closed and open when the door is open. If the door sensing
    switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control
    unit and make sure the door sensing switch is closed (either close the door or short the door sensing
    switch connecter). Use the Key unit matrix indicated on the control panel schematic and place a
    jumper wire between the pins that correspond to the STOP/CLEAR pad making momentary contact.
    If the control unit responds by clearing with a beep the key unit is faulty and must be replaced. If the
    control unit does not respond, it is faulty and must be replaced. If a specific pad does not respond,
    the above method may be used (after clearing the control unit) to determine if the control unit or key
    pad is at fault.
    5. Reconnect all leads removed from components during testing.
    6. Re-install the outer case (cabinet).
    7. Reconnect the power supply cord after
    the outer case is installed.
    8. Run the oven and check all functions.
    17
    8
    9
    026
    3
    4
    5BREAK
    FASTCUSTOM
    HELP
    POPCORN
    COMPU
    COOKCOMPU
    DEFROST
    POWER
    LEVELTURN
    TABLE
    ON / OFF
    WORK
    LIGHT
    NIGHT
    LIGHT
    FAN
    HI / LO STOP
    CLEAR
    START
    TOUCH ONMINUTE
    PLUS
    KITCHEN
    TIMER
    CLOCK SNACKS
    &
    REHEAT
    G 1G 2G 3G 4G 5G 6G 7G 8
    G 9 G10 G11 G12
    
     
    						
    All Sharp manuals Comments (0)

    Related Manuals for Sharp R-1480 Manual