Sharp R-1480 Manual
Have a look at the manual Sharp R-1480 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
9 R-1480 R-1481 R-1482 SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. COOKING TIME PROGRAMMED 3. VARIABLE COOKING CONTROL HIGH 4. START PAD TOUCHED Figure O-2. Oven Schematic-Cooking ConditionFigure O-1. Oven Schematic-Off Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY MAGNETRON TEMPERATURE FUSE FUSE 20A TURNTABLE MOTOR FAN MOTOR STIRRER MOTOR MAGNETRON OVEN LAMP MONITOR SWITCHBLK WHT POWER TRANSFORMER HIGH VOLTAGE CAPACITOR 0.94µF HIGH VOLTAGE RECTIFIER COM. N.O. COM. CONTROL UNIT GND GRN HOOD MOTORB7 B5 B3 B1High Low A1 A3 B9 A7 A5 N.O.E1 E2 DOOR SENSING SWITCH SECONDARY INTERLOCK SWITCH 120 V AC. 60 Hz HOOD LAMP HL HL RY3 RY1 RY2 PRIMARY INTERLOCK RELAY FMSTM OL TTM HOOD FAN THERMAL CUT OUT HOOD CAPACITORRY4 RY5 N.C. CAVITY THERMAL CUT-OUT SSR MAGNETRON TEMPERATURE FUSE FUSE 20A TURNTABLE MOTOR FAN MOTOR STIRRER MOTOR MAGNETRON OVEN LAMP MONITOR SWITCHBLK WHT POWER TRANSFORMER HIGH VOLTAGE CAPACITOR 0.94µF HIGH VOLTAGE RECTIFIER COM. N.O. COM. CONTROL UNIT GND GRN HOOD MOTORB7 B5 B3 B1High Low A1 A3 B9 A7 A5 N.O.E1 E2 DOOR SENSING SWITCH SECONDARY INTERLOCK SWITCH 120 V AC. 60 Hz HOOD LAMP HL HL RY3 RY1 RY2 PRIMARY INTERLOCK RELAY FMSTM OL TTM HOOD FAN THERMAL CUT OUT HOOD CAPACITORRY4 RY5 N.C. CAVITY THERMAL CUT-OUT SSR
10 R-1480 R-1481 R-1482 DESCRIPTION AND FUNCTION OF COMPONENTS DOOR OPEN MECHANISM The door is opened by pulling the door handle, refer to the Figure D-1.CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE DOOR SENSING SWITCH, PRIMARY INTERLOCK RELAY (RY2), SEC- ONDARY INTERLOCK SWITCH AND MONI- TOR SWITCH FOR PROPER OPERATION. (REFER TO CHAPTER TEST PROCEDURE). NOTE: MONITOR FUSE AND SWITCH ARE REPLACED AS AN ASSEMBLY TEMPERATURE FUSE (MG) The temperature fuse located near the waveguide is designed to prevent damage to the magnetron if an over heated condition develops in the tube due to cooling fan failure, obstructed air guide, dirty or blocked air intake, etc. Under normal operation, the temperature fuse remains closed. However, the temperature fuse will open at 302ûF (150ûC) causing the oven to shut down. THERMAL CUT-OUT (HOOD ) This thermal cut-out located on the right base plate. It is designed to automatically turn on the hood fan motor whenever the hot air rising from the conventional range below causes the temperature at the thermal cut-out to rise to 140ûF (60ûC) or higher, thus removing this hot air from around microwave oven. When the temperature around the thermal cut-out drops to 113ûF (45ûC) or lower, the thermal cut-out shuts off the hood fan motor. THERMAL CUT-OUT (CAVITY ) This thermal cut-out is located on the top of the oven cavity. It is designed to prevent damage to the oven unit if the food in the oven catches fire due to overheating produced by improper setting of cooking time or failure of control unit. Under normal operation, the thermal cut-out remains closed. However, the thermal cut-out will open at 293ûF (145ûC) causing the oven to shut down. TURNTABLE MOTOR The turntable motor rotates the turntable located on the bottom of the oven cavity, so that the foods on the turntable cook evenly during cooking. Turntable will turn in either direction. The turntable motor can be turned off by touching TURNTABLE ON/OFF pad. COOLING FAN MOTOR The cooling fan motor drives a blade which draws external cool air. This cool air is directed through the air vanes surrounding the magnetron and cools the magnetron. This air is channelled through the oven cavity to remove steam and vapors given off from the heating foods. It is then exhausted through the exhausting air vents at the oven cavity. HOOD FAN MOTOR The hood fan motor is a two-speed, single-phase, double pole induction type, requiring a hood fan capacitor. It is located outside the upper rear part of the oven cavity, is to remove, from around the oven, hot air rising from the conventional electric or gas range over which it is installed. Figure D-1. Door Open Mechanism DOOR SENSING AND SECONDARY INTERLOCK SWITCHES The secondary interlock switch is mounted in the lower position of the latch hook and the door sensing switch in the primary interlock system is mounted in the upper position of the latch hook. They are activated by the latch heads on the door. When the door is opened, the switches interrupt the circuit to all components. A cook cycle cannot take place until the door is firmly closed thereby activating both inter- lock switches. The primary interlock system consists of the door sensing switch and primary interlock relay located on the control circuit board. MONITOR SWITCH The monitor switch is activated (the contacts opened) by the latch head on the door while the door is closed. The switch is intended to render the oven inoperative by means of blowing the monitor fuse when the contacts of the primary interlock relay (RY2) and secondary interlock switch fail to open when the door is opened. Functions: 1. When the door is opened, the monitor switch contact close (to the ON condition) due to their being normally closed. At this time the primary interlock relay (RY2) and secondary interlock switch are in the OFF condition (contacts open) due to their being normally open contact switches. And the contacts of relay (RY1) are in the ON condition (contacts close). 2. As the door goes to a closed position, the monitor switch contacts are first opened and then the door sensing switch and the secondary interlock switch contacts close. (On opening the door, each of these switches operate inversely.) 3. If the door is opened, and the primary interlock relay (RY2) and secondary interlock switch contacts fail to open, the monitor fuse blows simultaneously with closing of the monitor switch contacts. Secondary Interlock Switch Monitor Switch Monitor Fuse Door Sensing Switch Latch Hook DoorLatch Heads
11 R-1480 R-1481 R-1482 TROUBLESHOOTING GUIDE Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected. When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the Test Procedure section. IMPORTANT:If the oven becomes inoperative because of a blown monitor fuse, check the monitor switch, relay (RY1) primary interlock relay (RY2), door sensing switch and secondary interlock switch before replacing the monitor fuse. If monitor fuse is replaced, the monitor switch must also be replaced. Use part FFS-BA016/ KiT as an assembly. IMPORTANT:Whenever troubleshooting is performed with the power supply cord disconnected. It may in, some cases, be necessary to connect the power supply cord after the outer case has been removed, in this event, 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the leads to the primary of the power transformer. 5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape. 6. After that procedure, reconnect the power supply cord. When the testing is completed 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Reconnect the leads to the primary of the power transformer. 5. Reinstall the outer case (cabinet). 6. Reconnect the power supply cord after the outer case is installed. 7. Run the oven and check all functions. This air is then expelled either vertically or horizontally through the customer supplied duct system, or discharged back into the kitchen. STIRRER MOTOR The stirrer motor drives the stirrer fan to stir the microwave radiation from the waveguide. HOOD LAMP The hood lamps are mounted at the hood lamp angle on the base cover. The hood lamps can be turned off and on by touching the WORK LIGHT pad or the NIGHT LIGHT pad. And also the brightness can be varied to high or low by touching the WORK LIGHT pad or the NIGHT LIGHT pad.
12 R-1480 R-1481 R-1482 CK = Check / RE = Replace POSSIBLE CASE AND DEFECTIVE PARTS PROBLEMTEST PROCEDURE CONDITIONOFF CONDITION IDLE CONDITIONMICROWAVE COOKING CONDITION Home fuse blows when power cord is plugged into wall receptacle. Monitor fuse blows when power cord is plugged into wall receptacle. Display does not illuminate when power cord is first plugged into wall receptacle. Display does not operate properly when STOP/CLEAR key is touched. (The time of day should appear on the display with beep sound during normal condition.) Oven lamp does not light with door is opened. Hood fan motor operates when power cord is first plugged into wall receptacle. Temperature of oven base seems more than 140˚F (60˚C) because of operation of the range below. But hood fan motor does not turn on automatically. (Normally, food fan motor should be operating at low speed.) Hood lights do not turn on when WORK LIGHT pad or NIGHT LIGHT pad is pressed. Hood fan motor does not rotate at all with touched FAN HI/LO pad. Speed of the hood fan motor does not change when the FAN HI/LO pad is touched for this function. Oven lamp does not light in cook cycle. (But it does light when door is opened.) Fan motor does not operate. (Oven lamp and turntable motor operate.) Turntable motor does not operate (Oven lamp lights and fan motor operate.) Oven does not go into cook cycle when START pad is touched Oven seems to be operating but little or no heat is produced in oven load. (Food incompletely cooked or not cooked at all at end of cook cycle.) Oven goes into a cook cycle but extremely uneven heating is produced in oven load (food). Variable cooking does not operate properly except Cooking Power 10 (P- HI) mode. Function of COMPU DEFROST does not operate properly. Stirrer motor does not operate. (Other parts operate.) Oven goes into COMPU DEFROST but food is not defrosted well. CK LOW VOLTAGE CK NO POWER AT OUTLET RE SHORTED IN POWER CORD CK OPENED OR SHORTED WIRING CK HOOD MOTOR CAPACITOR RE HOOD LAMP OR SOCKET CK TURNTABLE OFF CONDITION RE STIRRER MOTOR RE TURNTABLE MOTOR RE FAN MOTOR RE OVEN LAMP OR SOCKET P FOIL PATERN ON P.W.B. O COMPU DEFROST N RELAY (RY-5) N RELAY (RY-4) N RELAY (RY-3) N RELAY (RY-2) N RELAY (RY-1) M KEY UNIT L CONTROL UNIT K HOOD FAN MOTOR J HOOD HERMAL CUT-OUT I MONITOR FUSE H MONITOR SWITCH G PRIMARY INTERLOCK SYSTEM F SECONDARY INTERLOCK SWITCH E TEMPERATURE FUSE OR THERMAL CUT-OUT D HIGH VOLTAGE CAPACITOR C H.V. RECTIFIER B POWER TRANSFORMER A MAGNETRON
13 R-1480 R-1481 R-1482 BPOWER TRANSFORMER TEST TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm. 5. To test for a shorted magnetron, connect the ohmmeter leads between the magnetron filament leads and chassis ground. This test should indicate an infinite resistance. If there is little or no resistance the magnetron is grounded and must be replaced. 6. Reconnect all leads removed from components during testing. 7. Reinstall the outer case (cabinet). 8. Reconnect the power supply cord after the outer case is installed. 9. Run the oven and check all functions. MICROWAVE OUTPUT POWER The following test procedure should be carried out with the microwave oven in a fully assembled condition (outer case fitted). HIGH VOLTAGES ARE PRESENT DURING THE COOK CYCLE, SO EXTREME CAUTION SHOULD BE OBSERVED. Power output of the magnetron can be measured by performing a water temperature rise test. This test should only be used if above tests do not indicate a faulty magnetron and there is no defect in the following components or wiring: silicon rectifier, high voltage capacitor and power transformer. This test will require a 16 ounce (453cc) measuring cup and an accurate mercury thermometer or thermocouple type temperature tester. For accurate results, the following procedure must be followed carefully: 1. Fill the measuring cup with 16 oz. (453cc) of tap water and measure the temperature of the water with a thermometer or thermocouple temperature tester. Stir the thermometer or thermocouple through the water until the temperature stabilizes. Record the temperature of the water. 2. Place the cup of water in the oven. Operate oven at POWER 10(HIGH) selecting more than 60 seconds cook time. Allow the water to heat for 60 seconds, measuring with a stop watch, second hand of a watch or the digital read-out countdown. 3. Remove the cup from the oven and again measure the temperature, making sure to stir the thermometer or thermocouple through the water until the maximum temperature is recorded. 4. Subtract the cold water temperature from the hot water temperature. The normal result should be 27.7 to 51.5ûF(15.4 to 28.6ûC) rise in temperature. If the water temperatures are accurately measured and tested for the required time period the test results will indicate if the magnetron tube has low power output (low rise in water temperature) which would extend cooking time or high power output (high rise in water temperature) which would reduce cooking time. Because cooking time can be adjusted to compensate for power output, the magnetron tube assembly should be replaced only if the water temperature rise test indicates a power output well beyond the normal limits. The test is only accurate if the power supply line voltage is 120 volts and the oven cavity is clean. AMAGNETRON ASSEMBLY TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the primary input terminals and measure the resistance of the transformer with an ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of the primary coil should be less than 1 ohm and the resistance of the high voltage coil should be approximately 90 ohms; the resistance of the filament coil should be less than 1 ohm. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions.
14 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the terminals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indicate continuity for a short time and should indicate an open circuit once the capacitor is charged. If the above is not the case, check the capacitor with an ohmmeter to see if it is shorted between either of the terminals and case. If it is shorted, replace the capacitor. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. DHIGH VOLTAGE CAPACITOR TEST ECAVITY THERMAL CUT-OUT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. A continuity check across the thermal cut-out terminals should indicate a closed circuit unless the temperature of the thermal cut-out reaches approximately 293ûF(145ûC). An open thermal cut-out indicates overheating of the oven, exchange the oven thermal cut-out and check inside of oven cavity and for improper setting of cooking time or operation of control unit. Check for restricted air flow through the vent holes of the oven cavity, especially the cooling fan and air guide. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. MAGNETRON TEMPERATURE FUSE TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. A continuity check across the temperature fuse terminals should indicate a closed circuit. If the temperature of the magnetron reaches approximately 302ûF(150ûC), the temperature fuse opens. An open temperature fuse indicates overheating of the magnetron. Check for restricted air flow to the magnetron, especially the cooling fan air guide. 5. Reconnect all leads removed from components during testing. CHIGH VOLTAGE RECTIFIER TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the rectifier from the circuit. Using the highest ohm scale of the meter, read the resistance across the terminals and observe, reverse the leads to the rectifier terminals and observe meter reading. If a short is indicated in both directions, or if an infinite resistance is read in both directions, the rectifier is probably defective and should be replaced. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. NOTE: Be sure to use an ohmmeter that will supply a forward bias voltage of more than 6.3 volts. (HIGH VOLTAGES ARE PRESENT AT THE HIGH VOLTAGE TERMINAL, SO DO NOT ATTEMPT TO MEASURE THE FILAMENT AND HIGH VOLTAGE.)
15 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Check the monitor switch operation by using the ohmmeter as follows. When the door is open, the meter should indicate a closed circuit. When the monitor switch actuator is pushed by a screw driver through the lower latch hole on the front plate of the oven cavity 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. CAUTION: IF THE THERMAL CUT-OUT OR TEMPERATURE FUSE INDICATES AN OPEN CIRCUIT AT ROOM TEMPERATURE, REPLACE THERMAL CUT-OUT OR TEMPERATURE FUSE. 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the secondary interlock switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. FSECONDARY INTERLOCK SWITCH TEST HMONITOR SWITCH TEST GPRIMARY INTERLOCK SYSTEM TEST DOOR SENSING SWITCH 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the door sensing switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. NOTE: If the door sensing switch contacts fail in the open position and the door is closed, the cooling fan motor, stirrer motor and oven light will be activated by RY1. PRIMARY INTERLOCK RELAY (RY2) 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect two (2) wire leads from the male tab terminals of the Primary Interlock Relay. Check the state of the relay contacts using a ohmmeter. The relay contacts should be open. If the relay contacts are closed, replace the circuit board entirely or the relay itself. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions.
16 R-1480 R-1481 R-1482 IBLOWN MONITOR FUSE TEST TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary interlock switch and monitor switch according to the TEST PROCEDURE for those switches before replacing the blown monitor fuse. CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE PRIMARY INTERLOCK RELAY, SECONDARY INTERLOCK SWITCH, DOOR SENSING SWITCH AND MONITOR SWITCH FOR PROPER OPERATION. If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must be replaced with monitor fuse and monitor switch assembly part number FFS-BA016/KiT, even if the monitor switch operates normally. The monitor fuse and monitor switch assembly is comprised of a 20 ampere fuse and switch. 5. Reconnect all leads removed from components during testing. 6. Re-install the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions.with the door opened (in this condition the plunger of the monitor switch is pushed in), the meter should indicate an open circuit. If improper operation is indicated, the switch may be defective. After testing the monitor switch, reconnect the wire lead to the monitor switch (COM) terminal and check the continuity of the monitor circuit. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. Secondary Interlock SwitchMonitor Switch Screw Driver Ohmmeter Black White/White JHOOD THERMAL CUT-OUT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. A continuity check across the thermal cut-out terminals should indicate an open circuit unless the temperature of the thermal cut-out reaches approximately 140ûF(60ûC) or more. At that temperature, the contacts will close. The thermal cut-out opens automatically at approximately 113ûF(45ûC). 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. KHOOD FAN MOTOR TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the motor does not turn, touch the FAN HI / LO pad once (set hood fan motor power HIGH) and check voltage between pins 1 and 2 (Blue and Black wires) of the 6 pin connector. If 120 Volts appear and the hood capacitor is good, replace the hood fan assembly. If 120 Volts does not appear, check the motor circuit. The resistance values of motor terminals are as follows:
17 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST Resistance between; BLU (1) AND YLW (4) = 0W(Shorted) BLK (2) AND YLW (4) = 32W BLU (1) AND BLK (2) = 32W BLK (2) AND WHT (3) = 20W WHT (3) AND RED (5) = 45W 123 45 BLU BLK WHT YLW RED 6-PIN CONNECTOR OF HOOD FAN MOTOR 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. LTOUCH CONTROL PANEL ASSEMBLY TEST The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore, unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter and ohmmeter. In this service manual, the touch control panel assembly is divided into two units, Control Unit and Key Unit, and troubleshooting by unit replacement is described according to the symptoms indicated. Before testing, 1) Disconnect the power supply cord, and then remove outer case. Refer to procedure of HOOD EXHAUST LOUVER REMOVAL, REMOVAL OF OVEN FROM WALL and OUTER CASE REMOVAL. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Disconnect the leads to the primary of the power transformer. 5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape. 6) After that procedure, re-connect the power supply cord. 1. Key Unit. NOTE ; 1) Disconnect the power supply cord, and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Check key unit ribbon connection before replacement. 5) Reconnect all leads removed from components during testing. 6) Re-install the outer case (cabinet). 7) Reconnect the power supply cord after the outer case is installed. 8) Run the oven and check all functions. The following symptoms indicate a defective key unit. a) When touching the pads, a certain pad produces no signal at all. b) When touching a number pad, two figures or more are displayed. c) When touching the pads, sometimes a pad produces no signal. If the key unit is defective. 1) Disconnect the power supply cord, and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Replace the key unit. 5) Reconnect all leads removed from components during testing. 6) Re-install the outer case (cabinet). 32 ½ 20 ½ 45 ½ HOOD FAN CAPACITORYLW REDBLU BLK1 2 3 WHT 4 5
18 R-1480 R-1481 R-1482 TEST PROCEDURES PROCEDURE LETTERCOMPONENT TEST 7) Reconnect the power supply cord after the outer case is installed. 8) Run the oven and check all functions. 2. Control Unit. The following symptoms indicate a defective control unit. Before replacing the control unit, perform the Key unit test (Procedure M) to determine if control unit is faulty. 2-1 In connection with pads. a) When touching the pads, a certain group of pads do not produce a signal. b) When touching the pads, no pads produce a signal. 2-2 In connection with indicators a) At a certain digit, all or some segments do not light up. b) At a certain digit, brightness is low. c) Only one indicator does not light. d) The corresponding segments of all digits do not light up; or they continue to light up. e) Wrong figure appears. f) A certain group of indicators do not light up. g) The figure of all digits flicker. 2-3 Other possible problems caused by defective control unit. a) Buzzer does not sound or continues to sound. b) Clock does not operate properly. c) Cooking is not possible. When testing is completed, 1) Disconnect the power supply cord, and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Reconnect all leads removed from components during testing. 5) Re-install the outer case (cabinet). 6) Reconnect the power supply cord after the outer case is installed. 7) Run the oven and check all functions. MKEY UNIT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable is making good contact, verify that the door sensing switch (stop switch) operates properly; that is the contacts are closed when the door is closed and open when the door is open. If the door sensing switch (stop switch) is good, disconnect the flat ribbon cable that connects the key unit to the control unit and make sure the door sensing switch is closed (either close the door or short the door sensing switch connecter). Use the Key unit matrix indicated on the control panel schematic and place a jumper wire between the pins that correspond to the STOP/CLEAR pad making momentary contact. If the control unit responds by clearing with a beep the key unit is faulty and must be replaced. If the control unit does not respond, it is faulty and must be replaced. If a specific pad does not respond, the above method may be used (after clearing the control unit) to determine if the control unit or key pad is at fault. 5. Reconnect all leads removed from components during testing. 6. Re-install the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. 17 8 9 026 3 4 5BREAK FASTCUSTOM HELP POPCORN COMPU COOKCOMPU DEFROST POWER LEVELTURN TABLE ON / OFF WORK LIGHT NIGHT LIGHT FAN HI / LO STOP CLEAR START TOUCH ONMINUTE PLUS KITCHEN TIMER CLOCK SNACKS & REHEAT G 1G 2G 3G 4G 5G 6G 7G 8 G 9 G10 G11 G12