    							E-40
    Basic Operation
    Selecting the Menu Screen Position
    This function allows you to select the desired position
    of the menu screen.
    Description of Menu Position
    1Press MENU. The “Picture” menu screen appears.
    2Press 
    / to display the “Options” menu screen.
    3Press 
    / to select “Menu Position”, and then
    press 
    .
    4Press 
    / to select the desired menu position.
    5Press ENTER to save the setting.
    6To exit the menu screen, press MENU.
    2,3,41, 6
    5
    On-screen Display
    Center
    Upper Right
    Lower Right
    Upper Left
    Lower LeftThe menu is displayed on the center of the image.
    The menu is displayed on the upper right of the image.
    The menu is displayed on the lower right of the image.
    The menu is displayed on the upper left of the image.
    The menu is displayed on the lower left of the image.
    Description Selected
    item
    2,3,41, 6
    5
    Selecting the Menu Color
    This function allows you to select the color of the menu
    screen.
    Description of Menu color
    1Press MENU. The “Picture” menu screen appears.
    2Press 
    / to display the “Options” menu screen.
    3Press 
    / to select “Menu Color”.
    4Press 
    / to select “Opaque” (  ) or
    “Translucent”(     ).
    5To exit the menu screen, press MENU.
    Opaque ()
    Translucent
    (      )The menu is displayed opaquely.
    The menu is displayed translucently. The part of
    the menu on the image becomes transparent.
    Description Selected item
    On-screen Display
    DT-200(E)#p36_40.p6502.11.21, 11:43 AM 40 
    						
    							E-41
    Basic Operation
    Automatic Power Shut-off Function
    2,3,41, 5
    On-screen DisplayWhen no input signal is detected for more than 15
    minutes, the projector will automatically shut off. The
    on-screen message on the left will appear five minutes
    before the power is automatically turned off.
    Description of Automatic Power Shut-off
    1Press MENU. The “Picture” menu screen appears.
    2Press 
    / to display the “Options” menu screen.
    3Press 
    / to select “Auto Power Off”.
    4Press 
    / to select “” or “”.
    5To exit the menu screen, press MENU.
    • “Auto Power Off” is factory preset to “”.
    • When the Auto Power Off function is set to “ (On)”, 5
    minutes before the power turns off, the message “Power
    OFF in X min.” will appear on the screen to indicate the
    remaining minutes.
    Power automatically shuts off after 15 minutes without
    an input signal.
    Automatic Power Shut-off disabled.
    Description Selected
    item
    DT-200(E)#p41_42.p6502.11.21, 11:42 AM 41 
    						
    							E-42
    Basic Operation
    Reversing/Inverting Projected Images
    This projector is equipped with a reverse/invert image
    function which allows you to reverse or invert the pro-
    jected image for various applications.
    Description of Projected Images
    1Press MENU. The “Picture” menu screen appears.
    2Press 
    / to display the “PRJ Mode” menu
    screen.
    3Press 
    / to select the desired projection mode.
    4Press ENTER to save the setting.
    5To exit the menu screen, press MENU.
    •This function is used for the reversed image and ceiling-
    mount setups. See page 23 for these setups.
    On-screen Display
    2,31, 5
    4
    Selecting the On-screen Display Language
    English is the preset language for the On-screen
    Display; however, this can be changed to German,
    Spanish, Dutch, French, Italian, Swedish, Portuguese,
    Chinese, Korean or Japanese.
    1Press MENU. The “Picture” menu screen appears.
    2Press 
    / to display the “Language” menu
    screen.
    3Press 
    / to select the desired language.
    4Press ENTER to save the setting. The On-screen
    Display is now programed to display in the
    language selected.
    5To exit the menu screen, press MENU.
    2,31, 5
    4
    On-screen Display
    Selected item
    Front
    FrontCeiling
    Rear
    RearCeilingDescription
    Normal image
    Inverted image
    Reversed image
    Reversed and inverted image
    DT-200(E)#p41_42.p6502.11.21, 11:42 AM 42 
    						
    							E-43
    Maintenance &
    Troubleshooting
    Lamp/Maintenance Indicators
    Problem
    • Blocked air intake.
    • Clogged ventilative hole.
    • Cooling fan breakdown.
    • Internal circuit failure.
    • Burnt-out lamp.
    • Lamp circuit failure.
    • Lamp has been used for
    over 2,400 hours.Maintenance Indicator
    The internal
    temperature is
    abnormally high. TEMPERATURE
    WARNING indicatorCondition Possible Solution
    • Relocate the projector to an area with
    proper ventilation.
    • Clean the ventilative holes.
    (See page 48.)
    • Take the projector to your nearest Sharp
    Authorized Service Center or Dealer for
    repair.
    • Carefully replace the lamp. (See page 45.)
    • Take the projector to your nearest Sharp
    Authorized Service Center or Dealer for
    repair.
    Maintenance Indicators
    • The warning lights on the projector indicate problems
    inside the projector.
    • There are two types of warning lights: a TEMPERATURE
    WARNING indicator that warns you when the projector
    is too hot, and a LAMP REPLACEMENT indicator that
    warns you when to change the lamp.
    • If a problem occurs, either the TEMPERATURE
    WARNING indicator or the LAMP REPLACEMENT
    indicator will illuminate in red. After turning off the
    power, follow the procedures given below.
    • If the TEMPERATURE WARNING indicator lights up, follow the above possible solutions and then wait until the projector has
    cooled down completely before turning the power back on. (At least 5 minutes.)
    • If the power is turned off and then turned on again, for example during a brief rest, the LAMP REPLACEMENT indicator may
    be triggered, preventing the power from going on. Should this occur, unplug the power cord from the wall outlet and plug it
    back in again.
    TEMPERATURE
    WARNING
    indicatorPOWER
    indicator LAMP
    REPLACEMENT
    indicator
    LAMP REPLACE-
    MENT indicatorThe lamp does not
    light up.
    The lamp requires
    replacement.
    TEMP. LAMP POWER
    DT-200(E)#p43.p6502.11.21, 11:47 AM 43 
    						
    							E-44
    Maintenance &
    Troubleshooting
    Confirming the Lamp Usage Time
    Lamp Maintenance
    The lamp in this projector operates for approximately 2,500 cumulative hours, depending on the usage environ-
    ment. (As the usage environment can vary significantly, the projector lamp may not operate for 2,500 hours.) It is
    recommended that the lamp be replaced after approximately 2,400 cumulative hours of use or when you notice a
    significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen
    Display.
    CAUTION
    • Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.
    This function allows you to check the accumulated lamp
    usage time.
    1Press MENU. The “Picture” menu screen appears.
    2Press 
    / to display the “Options” menu screen.
    The lamp usage time will be displayed in “Lamp
    Timer”.
    3To exit the menu screen, press MENU.
    • It is recommended that the lamp be replaced after
    approximately 2,400 cumulative hours of use. See page 45
    for lamp replacement.
    On-screen Display
    Problem
    • Lamp has been used for over 2,400
    hours.
    • Lamp has been used for over 2,500
    hours.Possible Solution
    • Purchase a replacement lamp unit
    (lamp/cage module) of the current
    type BQC-XVZ90+++1 from your
    nearest Sharp Authorized Service
    Center or Dealer.
    • Replace the lamp. (See page 45.) If
    you wish, you may have the lamp
    replaced at your nearest Sharp
    Authorized Service Center or
    Dealer. Condition
    The LAMP REPLACEMENT
    indicator illuminates in red, and
    “LAMP” and “
    ” will blink in yellow
    in the lower-left corner of the image.
    A significant deterioration of the
    picture and color quality occurs.
    The power will automatically turn off
    and the projector will enter standby
    mode.
    “LAMP” and “
    ” will blink in red in
    the lower-left corner of the image,
    and the power will turn off.
    1, 3 2
    DT-200(E)#p44_45.p6502.11.21, 11:46 AM 44     
    						
    							E-45
    Maintenance &
    Troubleshooting
    Replacing the Lamp
    It is recommended that the lamp be replaced after approximately 2,400 cumulative hours of use or when you
    notice a significant deterioration of the picture and color quality. Carefully change the lamp by following the steps
    on the next page.
    If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized Service
    Center or Dealer for repair. Purchase a replacement lamp unit (lamp/cage module) of the current type
    BQC-XVZ90+++1 from your nearest Sharp Authorized Service Center or Dealer. Then carefully change the lamp
    by following the instructions on the next page. If you wish, you may have the lamp replaced at your nearest Sharp
    Authorized Service Center.
    IMPORTANT NOTE TO U.S. CUSTOMERS:
    The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
    projector under warranty, including lamp replacement, must be obtained through a 
    Sharp Authorized Service Center
    or Dealer. For the name of the 
    nearest Sharp Authorized Service Center or Dealer, please call toll-free: 1-800-BE-
    SHARP (1-800-237-4277).
    U.S.A. ONLY
    CAUTION
    •There is potential glass par ticles hazard if the lamp ruptures. In case of lamp rupture, contact your
    nearest Sharp Authorized Service Center or Dealer for replacement.
    •Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely
    hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage
    to fully cool down before removing the lamp cage.
    DT-200(E)#p44_45.p6502.11.21, 11:47 AM 45 
    						
    							E-46
    Maintenance &
    Troubleshooting
    Replacing the Lamp
    • Be sure to remove the lamp cage by the handle. Do not touch the glass surface of the lamp cage or the inside of the
    projector.
    • To avoid injury to yourself and damage to the lamp, carefully follow the steps below.
    • Replace the lamp after turning off the power and unplugging the power cord.
    Removing and installing the lamp unit
    CAUTION
    Turn off the power. Unplug the power cord.
    46
    Loosen the user service
    screw that secures the
    lamp cage cover.
    5
    Slide the lamp cage
    cover in the direction
    of the arrow.
    13Turn off the power.2Unplug the power cord.Remove the Swivel
    Stand. (See page 17.)
    Loosen and remove the
    three-securing screws
    from the lamp cage.
    Press POWER OFF. Wait until the
    cooling fan stops running.
    7Remove the lamp cage.
    User service screws
    Insert the new lamp cage
    firmly into the lamp cage
    compartment.89Tighten the three-
    securing screws to
    fasten the lamp cage.
    D
    T
    -2
    0
    0
    DT-200(E)#p46_47.p6502.11.21, 11:46 AM 46 
    						
    							E-47
    Maintenance &
    Troubleshooting
    •You need to reset the lamp timer ever y time you replace the lamp and confir m it is reset on the “Lamp Timer” menu.
    Replacing the Lamp
    11 10Attach the lamp unit
    cover.Tighten the user
    service screw to fasten
    the lamp cage cover.
    Press POWER ON on
    the projector to reset
    the lamp timer.
    Press , , , ,  and  in
    order. Then press 
    .
    Plug the power cord.12
    D
    T-200
    13
    “LAMP 0000H” is displayed on the
    screen.
    DT-200(E)#p46_47.p6502.11.21, 11:46 AM 47 
    						
    							E-48
    Maintenance &
    Troubleshooting
    • This projector is equipped with ventilative holes to ensure the optimal operating condition of the projector.
    • Periodically clean the ventilative hole by vacuuming it off with a vacuum cleaner.
    • The ventilative holes should be cleaned every 100 hours of use. Clean the ventilative holes more often when the
    projector is used in a dirty or smoky location.
    How to clean the ventilative holesSide and Rear view
    Cleaning the Ventilative Holes
    Clean the dust off by putting the
    cleaner hose on the intake
    ventilative holes.
    Cleaning.2Unplug the power
    cord.1
    Bottom view
    Intake ventilative holes
    Intake ventilative holesCleaner
    hose
    Intake ventilative holes
    Swivel stand
    DT-200(E)#p48_49.p6502.11.21, 11:46 AM 48 
    						
    							E-49
    Maintenance &
    Troubleshooting
    Troubleshooting
    Check
    •Projector power cord is not plugged into the wall outlet.
    •Selected input is wrong. (See page 24.)
    •Cables incorrectly connected to back panel of the projector. (See pages 12–15.)
    •“Contrast” and “Bright” adjustments are set to minimum position.
    •Picture adjustments are not correct.
    •Adjust the focus. (See page 16.)
    •Projection distance is too long or too short to allow for proper focus. (See pages 21 and 22.)
    •OSD Display is set to “OFF”, preventing to display some or all On-screen Displays. (See
    page 36.)
    •If the picture is nor mal, the sound is due to cabinet shrinkage caused by temperature
    changes. This will not affect operation or per formance of the projector.
    •Refer to “Lamp/Maintenance Indicators” on page 43.
    •Adjust the “Phase” setting. (See page 33.)
    •Change the input signal type. (See page 36.)
    Service Information (For the U.S.)
    For the location of the nearest Sharp Authorized Service Center, or to obtain product literature, accessories,
    supplies or customer assistance, please call 1-800-BE-SHARP (1-800-237-4277) or visit SHARP’s website
    (http://www.sharpusa.com).
    Problem
    No picture appears.
    Color is faded or poor.
    Picture is blurred.
    No OSD appears.
    An unusual sound is occasion-
    ally heard from the cabinet.
    Maintenance indicator
    illuminates.
    Picture noise appears.
    Image is green on INPUT 2
    Component.
    Image is pink (no green) on
    INPUT 2 RGB.Kensington Security
    Standard connector
    This projector has a Kensington Security Standard
    connector for use with a Kensington MicroSaver Security
    System. Refer to the information that came with the
    system for instructions on how to use it to secure the
    projector.
    Rear View
    Using the Kensington Lock
    DT-200(E)#p48_49.p6502.11.21, 11:46 AM 49 
    						